Duke Freeport-LR160727 (4)July 27, 2016
Duke Realty
South/West Region
14241 North Dallas Parkway, Suite 1000
ATTN:Mr. Sean Jeanes, P.E. LEED AP
Tohatsu
Location:
Permits:
Dallas, TX 75254
19:6710-A
NEC Bethel Road and Freeport Parkway
Coppell, TX
RE:
ECS Job #
3033 Kellway Drive, Suite 110
Carrollton, TX 75006
(972) 392-3222 [Phone]
(214) 483-9684 [Fax]
ECS Texas, LLP
LETTER OF TRANSMITTAL
Texas Registered Engineering Firm # F-8461
CC:Duke Realty - Todd Henry
Duke Realty - Glen Stevenson
Pacheco Koch Consulting Engineers - Clayton J. Strolle, LEED AP
City of Coppell - Matt Mabry
Weir Bros., Inc. - Mike Weir
Meinhardt & Associates - David Meinhardt
LJB inc - Jim Lintz
ENCL:
We are enclosing:
Materials Engineering Division Reports
For your use
As requested
X
X
X
Field Report # 83A 07/22/2016 Structural Steel Non Compliance
Noted
Timothy TarbuttonMark R. Zortman, P.E.
Principal Engineer Project ManagerJUL 26 2016
1000.1
This report (and any included attachments) shall not be reproduced, except in full, without the prior written approval of ECS.
ECS Texas, LLP
19:6710-A
83A
Tohatsu Friday 07/22/2016
Project No.
Report No.
Day & DateProject
3033 Kellway Drive, Suite 110
Carrollton, TX 75006
(972) 392-3222 [Phone]
(214) 483-9684 [Fax]
FIELD REPORT
5.50
Visual Structural Steel Observation:
On this date, a representative of ECS, arrived on site as requested to perform a visual
observation of the structural steel installation.
An Observation Report is attached. The remarks and/or discrepancies are noted on the
report.
55.00
5.50
0.00
0.00
*** Non Compliance Noted ***
10:00A 03:30P
Structural Steel
Location
Contractor
On-Site Time
Lab Time
Client
Coppell, TX
Arrival Departure
Summary of Services Performed (field test data, locations, elevations & depths are estimates) & Individuals Contacted.
Duke Realty - Sean Jeanes, P.E. LEED AP
Duke Realty - Sean Jeanes, P.E. LEED AP
Trip Charges*
Remarks
Chargeable Items
Weather
Mileage*
0.00Travel Time*
Total
Time of
Re Obs.Time
* Travel time and mileage will be billed in accordance with the contract.
Tolls/Parking*
SUBCONTRACTORBy 7100
1088720
REPORT OF
STRUCTURAL STEEL INSPECTION
Project:Tohatsu Report No:52353-6
670 Freeport Pkwy, Coppell, TX Attention:
Client:ECS - Texas, LLP Date of Service:7/22/2016
4950 Keller Springs Road #480
Addison, TX 75001 Page 1 of 1
REPORT OF INSPECTION
Drawings utilized:Structural
Locations/item inspected:As Noted Below
Discrepancies/comments:
A visual inspection was performed and the results are as follows:
I.) Joist Welds A-F/1-5
* 1.) Joist welds at west wall not enough bearing, engineer please advise, 1-1/2"-2" bearing.
* 2.) Joist girder to pockets on south wall 3-1/2" bearing needs 4", engineer please advise.
3.) Joist Seat to Punch Welds - Compliant
4.) Joist Girder to Column Welds - Compliant
5.) Remainder of Joist Welds - Compliant
II.) Column to Embeds - All Comply
* - Open Items
Mark Ledbetter, CWI #01100411
Technician Steel Inspectors of Texas, Inc.
This report is for the exclusive use of our client and shall not be modified or reproduced without written approval from said client