Loading...
Duke Freeport-LR160727 (4)July 27, 2016 Duke Realty South/West Region 14241 North Dallas Parkway, Suite 1000 ATTN:Mr. Sean Jeanes, P.E. LEED AP Tohatsu Location: Permits: Dallas, TX 75254 19:6710-A NEC Bethel Road and Freeport Parkway Coppell, TX RE: ECS Job # 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP LETTER OF TRANSMITTAL Texas Registered Engineering Firm # F-8461 CC:Duke Realty - Todd Henry Duke Realty - Glen Stevenson Pacheco Koch Consulting Engineers - Clayton J. Strolle, LEED AP City of Coppell - Matt Mabry Weir Bros., Inc. - Mike Weir Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz ENCL: We are enclosing: Materials Engineering Division Reports For your use As requested X X X Field Report # 83A 07/22/2016 Structural Steel Non Compliance Noted Timothy TarbuttonMark R. Zortman, P.E. Principal Engineer Project ManagerJUL 26 2016 1000.1 This report (and any included attachments) shall not be reproduced, except in full, without the prior written approval of ECS. ECS Texas, LLP 19:6710-A 83A Tohatsu Friday 07/22/2016 Project No. Report No. Day & DateProject 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] FIELD REPORT 5.50 Visual Structural Steel Observation: On this date, a representative of ECS, arrived on site as requested to perform a visual observation of the structural steel installation. An Observation Report is attached. The remarks and/or discrepancies are noted on the report. 55.00 5.50 0.00 0.00 *** Non Compliance Noted *** 10:00A 03:30P Structural Steel Location Contractor On-Site Time Lab Time Client Coppell, TX Arrival Departure Summary of Services Performed (field test data, locations, elevations & depths are estimates) & Individuals Contacted. Duke Realty - Sean Jeanes, P.E. LEED AP Duke Realty - Sean Jeanes, P.E. LEED AP Trip Charges* Remarks Chargeable Items Weather Mileage* 0.00Travel Time* Total Time of Re Obs.Time * Travel time and mileage will be billed in accordance with the contract. Tolls/Parking* SUBCONTRACTORBy 7100 1088720 REPORT OF STRUCTURAL STEEL INSPECTION Project:Tohatsu Report No:52353-6 670 Freeport Pkwy, Coppell, TX Attention: Client:ECS - Texas, LLP Date of Service:7/22/2016 4950 Keller Springs Road #480 Addison, TX 75001 Page 1 of 1 REPORT OF INSPECTION Drawings utilized:Structural Locations/item inspected:As Noted Below Discrepancies/comments: A visual inspection was performed and the results are as follows: I.) Joist Welds A-F/1-5 * 1.) Joist welds at west wall not enough bearing, engineer please advise, 1-1/2"-2" bearing. * 2.) Joist girder to pockets on south wall 3-1/2" bearing needs 4", engineer please advise. 3.) Joist Seat to Punch Welds - Compliant 4.) Joist Girder to Column Welds - Compliant 5.) Remainder of Joist Welds - Compliant II.) Column to Embeds - All Comply * - Open Items Mark Ledbetter, CWI #01100411 Technician Steel Inspectors of Texas, Inc. This report is for the exclusive use of our client and shall not be modified or reproduced without written approval from said client