Loading...
Duke Freeport-LR160816 (3) ECS Texas, LLP 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 LETTER OF TRANSMITTAL (972) 392-3222 \[Phone\] (214) 483-9684 \[Fax\] Texas Registered Engineering Firm# F-8461 August 16, 2016RE:Tohatsu Duke RealtyECS Job #19:6710-A South/West Region 14241 North Dallas Parkway, Suite 1000Permits: Dallas, TX 75254Location:NEC Bethel Road and Freeport Parkway Coppell, TX ATTN:Mr. Sean Jeanes, P.E. LEED AP We are enclosing: XMaterials Engineering Division Reports XFor your use XAs requested CC:Duke Realty - Todd Henry Duke Realty - Glen Stevenson Pacheco Koch Consulting Engineers - Clayton J. Strolle, LEED AP City of Coppell - Matt Mabry Weir Bros., Inc. - Mike Weir Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz ENCL: Field Report # 9608/15/2016Pavement SG Comp. Mark R. Zortman, P.E. Timothy Tarbutton AUG 16 2016 Principal Engineer Project Manager This report (and any included attachments) shall not be reproduced, except in full, without the prior written approval of ECS. 1000.1 ECS Texas, LLP 3033 KellwayDrive, Suite 110 Carrollton, TX 75006 FIELD REPORT (972) 392-3222 \[Phone\] (214) 483-9684 \[Fax\] 19:6710-A Project No. 96 Report No. TohatsuMonday 08/15/2016 ProjectDay & Date 65°/ Rain Weather Coppell, TX Location 2.00 On-Site Time Duke Realty - Sean Jeanes, P.E. LEED AP Client 0.50 Lab Time Duke Realty - Sean Jeanes, P.E. LEED AP Contractor 1.00 Travel Time* 3.50 Total 0.00 Re Obs.Time Pavement SG Comp. Remarks Time ofArrivalDeparture 55.00$4.68 Trip Charges*Tolls/Parking*Mileage* 06:00A08:00A 1 - Nuclear Gauge Rental Chargeable Items * Travel time and mileage will be billed in accordance with the contract. Summaryof Services Performed (field test data, locations, elevations & depths are estimates) & Individuals Contacted. The undersigned arrived on site, as requested, to observe the compaction of soils for Pavement Subgrade. Tests taken on this date are re-tests of non-compliant areas tested on 08/09/2016 in Field Report 92. Utilizing the nuclear test method to check the compaction of soils; test results indicated that the compacted material, at the areas and elevations tested, met or exceeded the project requirements of 95% of the maximum drydensityand moisture content above OMC as obtained in our laboratoryusing the ASTM D 698-12 Method A Standard. Locations and elevations of all tests are based on stakeout provided byothers. We cannot be responsible for structures located off of the observed engineered pad, misaligned utilities or stakeout errors causing uncontrolled fill to be placed in structural areas. Yonas Belete Alemu, — Technician Introductory1800 By 1090690 Uncorrected Opt. MC Comments non-compliantnon-compliantnon-compliantnon-compliantnon-compliant :65090 Re-test ofRe-test ofRe-test ofRe-test ofRe-test of areas fromareas fromareas fromareas fromareas from Report 92Report 92Report 92Report 92Report 92 08/15/16 WO Uncorrected Max. Density Page 1 P / F Date: PPPPP Percent Comp. (%) 96.097.296.696.195.9 Content Moisture (%) 13.612.811.010.612.2 3437 344 Test Data Density (pcf) 112.0113.4116.3115.7111.9 Dry Test Method ASTM Nuclear Moisture Std Density Density Std (pcf)127.2127.9129.0128.0125.5 t We Corrected STM Nuclear Moisture Content Optimum 11.4011.4010.4610.4611.40 (%) Proctor Method 8899 Nuclear Gauge No.Corrected Maximum Humboldt Density 116.70116.70120.40120.40116.70 (pcf) Dry 5001-EZ Oversize , A 10.0010.00 Ser. No. 0.000.000.00 Tohatsu % Model Field Compaction Summary Make Sample No. Project Name: D4S-5D4S-5D4S-5D4S-5D4S-5 Lift / Elev SGSGSGSGSG Test Mode: DT = Direct Transmission BS = Back Scatter u Yonas Belete Alem Duke Realty Duke Realty Description 6710-A Technician: Contractor: Project No: Client: ent Subgradeent Subgradeent Subgradeent Subgradeent Subgrade Station / Location PavemPavemPavemPavemPavem Depth Probe S, LLP (in.) 66666 Sample No. Mode Test ECS TEXA DTDTDTDTDT Test No. 12345