Loading...
Duke Freeport-LR160816 (4) ECS Texas, LLP 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 LETTER OF TRANSMITTAL (972) 392-3222 \[Phone\] (214) 483-9684 \[Fax\] Texas Registered Engineering Firm# F-8461 August 16, 2016RE:Tohatsu Duke RealtyECS Job #19:6710-A South/West Region 14241 North Dallas Parkway, Suite 1000Permits: Dallas, TX 75254Location:NEC Bethel Road and Freeport Parkway Coppell, TX ATTN:Mr. Sean Jeanes, P.E. LEED AP We are enclosing: XMaterials Engineering Division Reports XFor your use XAs requested CC:Duke Realty - Todd Henry Duke Realty - Glen Stevenson Pacheco Koch Consulting Engineers - Clayton J. Strolle, LEED AP City of Coppell - Matt Mabry Weir Bros., Inc. - Mike Weir Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz ENCL: Field Report # 9508/13/2016Wall Footing Mark R. Zortman, P.E. Timothy Tarbutton AUG 16 2016 Principal Engineer Project Manager This report (and any included attachments) shall not be reproduced, except in full, without the prior written approval of ECS. 1000.1 ECS Texas, LLP 3033 KellwayDrive, Suite 110 Carrollton, TX 75006 FIELD REPORT (972) 392-3222 \[Phone\] (214) 483-9684 \[Fax\] 19:6710-A Project No. 95 Report No. TohatsuSaturday 08/13/2016 ProjectDay & Date 75°/ Cloudy Weather Coppell, TX Location 6.50 On-Site Time Duke Realty - Sean Jeanes, P.E. LEED AP Client 0.50 Lab Time Duke Realty - Sean Jeanes, P.E. LEED AP Contractor 1.42 Travel Time* 8.42 Total 0.00 Re Obs.Time Wall Footing Remarks Time ofArrivalDeparture 55.00 Trip Charges*Tolls/Parking*Mileage* 07:30A02:00P Chargeable Items * Travel time and mileage will be billed in accordance with the contract. Summaryof Services Performed (field test data, locations, elevations & depths are estimates) & Individuals Contacted. The undersigned arrived on site, as requested, to observe the placement of 22 cubic yards of 3000 psi concrete for Wall Footing. The required test limits were determined to be a slump of 3-5 inches, air content of 0-3 %, batch to placement time of 90 minutes, and concrete temperature range of 50-95 degrees Fahrenheit. Concrete observed on this date appeared to be placed in compliance with project specifications with regard to temperature, slump, air content, and batch to placement time. One set of five laboratorycured concrete cylinders were cast for compressive strength testing in our laboratory. Prior to the placement of concrete reinforcing steel was observed and appeared to be installed in accordance with plans and specifications. Previouslynoted deficiencies have been corrected. Yonas Belete Alemu, — Technician Introductory1800 By 1090447 :65083 WO Page 1 Location and Remarks ECS Texas, LLP u 2000.1.1.0 Yonas Belete Alem Duke Realty / 75 08/13/2016 3000 psi Cloudy 6710-A Project No. Client: Weather / Temp: Day/Date:* Design Strength: By: Water Added Concrete p. 75 Tem 1.10(P) % Air 3.25 Slump 3000 psi Report B to P min. Mix Strength: 859081 NEC Bethel Road and Freeport Parkway - TX 75019- 10:3010:4012:30 Concrete Summary Finish Truck Time Coppell, - Dallas County 09:4510:0011:50 Arrive Duke Realty 09:0509:1011:09 Batch e Tim Tohatsu * B to P - Batch to Placement time in minutes 5150 9.0 19.022.0 LMC CY Concrete Cum Project:Supplier: Mix Designation: Location: Contractor : 9.03.0 10.0 Truck 637193306371933763719351 ll Footing Ticket No. Wa Truck No. 015102310212 * Location: No. 123