Loading...
Duke Freeport-LR160816 (5) ECS Texas, LLP 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 LETTER OF TRANSMITTAL (972) 392-3222 \[Phone\] (214) 483-9684 \[Fax\] Texas Registered Engineering Firm# F-8461 August 16, 2016RE:Tohatsu Duke RealtyECS Job #19:6710-A South/West Region 14241 North Dallas Parkway, Suite 1000Permits: Dallas, TX 75254Location:NEC Bethel Road and Freeport Parkway Coppell, TX ATTN:Mr. Sean Jeanes, P.E. LEED AP We are enclosing: XMaterials Engineering Division Reports XFor your use XAs requested CC:Duke Realty - Todd Henry Duke Realty - Glen Stevenson Pacheco Koch Consulting Engineers - Clayton J. Strolle, LEED AP City of Coppell - Matt Mabry Weir Bros., Inc. - Mike Weir Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz ENCL: Non Compliance Field Report # 9408/12/2016Comp, Reinf. Steel Noted Mark R. Zortman, P.E. Timothy Tarbutton AUG 16 2016 Principal Engineer Project Manager This report (and any included attachments) shall not be reproduced, except in full, without the prior written approval of ECS. 1000.1 ECS Texas, LLP 3033 KellwayDrive, Suite 110 Carrollton, TX 75006 FIELD REPORT (972) 392-3222 \[Phone\] (214) 483-9684 \[Fax\] 19:6710-A Project No. 94 Report No. TohatsuFriday 08/12/2016 ProjectDay & Date 97°/ Sunny Weather Coppell, TX Location 5.75 On-Site Time Duke Realty - Sean Jeanes, P.E. LEED AP Client 0.25 Lab Time Duke Realty - Sean Jeanes, P.E. LEED AP Contractor 1.50 Travel Time* *** Non Compliance Noted *** 7.50 Total 0.00 Re Obs.Time Comp, Reinf. Steel Remarks Time ofArrivalDeparture 55.00 Trip Charges*Tolls/Parking*Mileage* 09:00A02:45P 1 - Nuclear Gauge Rental Chargeable Items * Travel time and mileage will be billed in accordance with the contract. Summaryof Services Performed (field test data, locations, elevations & depths are estimates) & Individuals Contacted. The undersigned arrived on site, as requested, to observe: 1. The compaction of soils for Fire Lane and Ramp. Utilizing the nuclear test method to check the compaction of soils; test results indicated that the compacted material, at the areas and elevations tested: - met or exceeded the project requirements of (95% compaction, OMC +2%) for Ramp - did not meet the project requirements (95% compaction, +OMC) for Fire Lane subgrade. Locations and elevations of all tests are based on stakeout provided byothers. We cannot be responsible for structures located off of the observed engineered pad, misaligned utilities or stakeout errors causing uncontrolled fill to be placed in structural areas. 2. The installation of reinforcing steel at wall footing. There was a section without anyreinforcing steel at time of observations. The project superintendent was notified. Please see the attached photos. Zerubabel A. Gudeta, — Field Technician1800 By 1090338 Uncorrected Opt. MC Comments :65038 08/12/16 WO Uncorrected Max. Density Page 1 P / F Date: FFFFPPPP Percent Comp. (%) 99.994.695.394.695.698.996.395.6 Content Moisture (%) 10.410.416.114.416.015.2 6.49.4 2106 681 Test Data Density (pcf) 116.6110.4111.2110.4111.6115.4112.4111.6 Dry Test Method ASTM Nuclear Moisture Std Density Density Std (pcf)124.1121.9121.7121.9129.5132.0130.4128.6 t We Corrected STM Nuclear Moisture Content Optimum 11.4011.4011.4011.4011.4011.4011.4011.40 (%) 28772 Proctor Method Nuclear Gauge No.Corrected Maximum Density 116.70116.70116.70116.70116.70116.70116.70116.70 (pcf) Dry Troxler 3440 Oversize , A Ser. No. 0.000.000.000.000.000.000.000.00 Tohatsu % Model Field Compaction Summary Make Sample No. Project Name: D4S-5D4S-5D4S-5D4S-5D4S-5D4S-5D4S-5D4S-5 SG-2'SG-2'SG-1'SG-1' Lift / Elev SGSGSGSG Test Mode: DT = Direct Transmission BS = Back Scatter Zerubabel A. Gudeta Duke Realty Duke Realty Description 6710-A Technician: Contractor: Project No: Client: Station / Location Fire laneFire laneFire laneFire lane RampRampRampRamp Depth Probe S, LLP (in.) 60006666 Sample No. Mode Test ECS TEXA DTDTDTDTDTDTDTDT Test No. 12345678