Loading...
WA9301-SP 980417Date: April 17, 1998 To: Bar Constructors, Inc. P.O. Box 10 Lancaster, Texas 75146-0010 Attention: Ms. Lucy Garcia Subject: Coppell 2 Metering Station Contract No. 94-81 City of Dallas Submittal No. Gentlemen: We are returning the following submittal dam: IDENTIFICATION DESCRIPTION Markel Series 5100 Series 5100 Taskmaster Electrical Unit Heater 16880-01 DISPOSITION 9 3 X Distribution: Design Engineer - 1 Project Manager - 5 (File - 1), (Field - 1), (Coppell - 1), (Pumping - 1) QDeDegn Services Water Utilities Department Design Services · 320 E. Jefferson, Rm 213 · Dallas. Texas 75203· 214 / 948-4576· FAX 214 / 948-4599 A dty utility providing regional water and wastewater services vital to public health and safety. City of Dallas WATER UTILITIES DEPARTMENT PRODUCT SUBMITTAL T.ns~r~ No. I ~% O-OI Contract No.: 9at j~ Plan Sheet Reference: Specification Section: Manufacturer: Dimensions: ~,~,k~l t~nr~ Elec4. 14~,~4ec Detail No.: Item No.: Model No.: Color/Texture: This submittal consists of (Select): Product Data 0 & M Inslructions Manufaeturer's Test Report Material Schedule Other. Shop Drawings Installation InsWuctions Manufaeturer's Approval of Installer Samples (describe): Contractor' s Review Stamp Engineer's Review Stamp NO EXCEPTION TAKEN MAKE CORRECTIONS NOTED REVISE AND RESUBMIT REJECTED FOR RECORD ONLY REVIEW BY THE ENGINEER DOES NOT RELIEVE THE CONTP, ACTOR FROM RESPONSIBILITY FOR CONFORMANCE WITH CONTRACT REQUIREMENTS. PROJECT C CONTRACT DALLAS WATER UTILITIES DEPT. '"" · Markel Date: March 17,199 mitted By: H.R. Capers Co. Indu=trlal · Commercial · Residential * Institutional .... Job: Coppell 2 Metering Station Eng.: Henry Niblo Loc.: City of Dallas, TX Cont.: Bar Constructors ..'~ _jy' , m, Unit Heaters ,,,,, ., ~, ,~: CAPACff!ES ' · ..... ';:- --' Kw ..'. i: ;:~:'--_:-;.,:-,, ::'~'~;;::"' .. '~- -. ,, 208, 240, 480, 600 Mechanical SpecificsHa: Hemera shall be installed and wired in accordance with the manufacturers recom- mendations and applicable national and local codes, Caring: Casings fabricated of die-formed, heavy-gauge steel and finished in high gl_,~'s__, baked eReeeL Supply mar drawn through a stamped Iouver periphery evenly across the heating element, and discharged through an outward drawn venturi. Adjustable discharge Iouvers provided to control the direction of airflow, A large hinged access door extends the width of the heater and locked in position by quarter-turn fastener~ Heater and supply wiring diagram permanently attached to the inside of the access door. Elements: Elements are high mass, all steel, tubular fanned type. Motors: Motors totally enclosed, all angle industrial rated. All unite 2,5 through 20 kw utilize sealed bearings to insure permanent lubrication. 25 through 50 kw units are provided with a two-speed, permanent capacitor-type, lubricated for 5 years of continuous or 10 years of intermittent usa, Fan Bides: Fan blades are axial flow-type designed for quiet efficient operation. Fan speed does not exceed 1,600 rpm. WIrtn~: Heaters designed for a single circuit, with ele- ments, motor, and control circuits subdivided with factory wire fuses to conform to the National Electric Code and Underwriter's Laboratory, Inc. Standard 1025. All three- phase heaters have balanced phases. Thermal Overtoed Protection: All heaters equipped with manual reset thermal overtoads which shutdown the element and motor if safe operating temperatures are exceeded. Control: Contactore and control 'circuit transformera where required are factory installed and wired. Only direct line supply and thermostat connections in the field are required. Two-stage operation standard on real units 25 kw and larger with use of. two-stage thermostats. Built-in fan overTida provided to purge unit casing of excess heat attar unit shutdown. The units are listed under the Re- examination .Service of Underwriter's Laboratories, Inc. Units are warranted to be free from defective' material and workmanship for a period of I year with the exception of the heating elements which are warranted for 5 years. Control Options · Integral power disconnects-(where applicable)- supplied to disconnect all ungrounded connectors in the "Off" position. Disconnect isolated from unit wiring by usa of a metal plate and filCh'paper- * Thermostats (unit*mounted); (wall-m~unted) - heavyduty 4 hydraulic actuating-type;TI;mrmoste{ range 5 F to 90 E Unit-mounted thermostat can. ~ rendered tamperproof by removing the temperalum edjUstment knob. ~ · Independent fan operation fc~r..summer mar circulation provided from a line Or low -voltage (unit-mounted)~ (wall-mounted) fan switcll. ' · Combination Iow'vditagel will thermostat and fan switch- -- provided to give ,wall mounted control of element and fan. ..: ' .!' · Stratification thermostat w~th:a rang~. of 7.0 F to i30 provided for unite 'mounted ~in the 'Vert~i diSch~ position to proy!idl9 a~:e~erily saver cycle recovehng warm .ratified ~r..;~ ": ,': ~:. :: INSTALLATION INSTRUCTIONS & PARTS LIST ATTENTION: READ CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE OR SERVICE THE TASKMASTER UNIT HEATER. RETAIN THESE INSTRUCTIONS FOR FUTURE USE. FEATURES Forced air electdc unit heater available in 208, 2401208, 277, 480 or 600 volt as standard. Ten standard heating capacities of 3.3 KWI11,260 BTUH thru 50.0 KWI170,600 BTUH. 208 and 240/208 volt models are single phase field con- vertible to three phase on 3.3 thru 10.0 KW Models. (Single phase only available on 3.3, 5.0, 7.5 and 10 KW 277 volt models. Specially designed inlet Iouver allows the fan to pull cool air evenly across the high mass all-steel element. Outward drawn venturi and adjustable Iouver assembly further directs the outlet air in a uniform pattern to meet specific air pattern requirements in either the horizontal ,,...,or vertical mounting position. Optional wall/ceiling or vertical mounting brackets. (As required). Four position weld nuts supplied in case top and back for field mounting by drill rods or eye bolt with chain. (Hard- ware supplied by others.) Optional radial or anemostat diffusers lending air pattem versatility when mounted vertically. Modular control kits for field installation. Disconnect switch, thermostat, summer fan switch, heat recovery ther- mostat. All kits with spade terminals (Except disconnect switch). Single point terminal board wiring of integral control kits. 24 volt low voltage control circuit standard on all contac- tor and transformer models. Roomy control box with access door locked into position by two (2) 1/4 turn fasteners for ease of installation. Revised 10/95 Form 9632 PROPER LOCATION INg'~UCTIONS Once the total heating load is calculated, the quantity and capacity of the unit heaters must be determined, Because a large number of Iow-capac~y heaters provides more uniform heat distribution, this approach is recommended when the area will be occupied by a relatively large number of sedentary personnel, perhaps working on pro- duction lines and at benches, A large number of smaller capacity unit heaters tends to prevent hot drafts, reduces noise levels, and increases diversity of load to help reduce electrical demand and operating costs. In warehouse where even heat distribution and constant temperatures are less important, a smaller number of high capacity units can be used - in many cases reducing first cost. To maintain reasonable heat distribution and reduce severe etretifioation even in lower bey areas, the total air volume of the space should pass through the unit heaters about three times per hour. (Take total cubic feet and divide by 20 in order to determine proper total heater CFM rating.) It is important that the rated voltage of the heating equip- mant match the supply voltage. Supply voltage in excess of the heater rated voltage can damage equipment. Supp- ly voltage lower than the rated heater voltage will decr~ar.3 heater output as well as run the risk of damaging some ,,,'omponents. Horizon!el unit he~ s am recommended in low bay areas with maximum 15 to 18 foot ceilings. These should be con- centrated along outside wall or other areas of greatest heat loss, spaced to set up a generally circular air move- ~ ment, each heater supporting the air stream of the other.' Additional vertical down blow unit heaters with appropriate accessory diffusers can be located to counterect ceiling heat losses. E] GENERAL SAFETY INFORMATION CAUTION: Follow all iooal electrical and safety code, as well as the National Electrical Code (NEC) and the Occupational Safety end Health Act (OSHA). To avoid possible electrical shock, be sure the electrical current is turned off at the main switch prior to wiring or servicing of unit. If the power disconnect is not integral and is out-of-sight,' lock it in the open position and tag to prevent unexpected application of power pdor to performing any service or maintenance on the unit. The unit when installed must be electrically grounded in accordance with the National Electrical Code and stan- dard industry practice. 2 Make certain that the power source conforms to the re- quirernents of your equipment. See Table 2 for informa- tion as to wire size, circuit size, etc. Check heater voltage and phase on rating label to con- firm it is the same as the electric service supply. Wiring diagrema of the heaters and supply connections are permanenUy attached to the inside of the heater ac- cess door. All terminals are coded in accordance with the wiring diagram. Accessory wiring are shown on the unit widng diagram and supporting literature. The heater must be mounted at least 7' above the floor to prevent accidental contact with the fen blade which could cause injury. Install unit so there are no obstruc- tions to the intake or discharge. Maintain clearances as shown on Table 1, 2, Fig. I & 2. The wail/ceiling mounting structure and anchoring provi- sions must be of sufficient strength to support the corn- bined weight of the heater and mounting bracket. Upon a c t I mounted optional accessory thermostat, the unit fan motor and heating elements shall be energized and remain on until 'emperature reaches setting of thermostat; at which time /'< · heating elements shall be aleenergized. The fan motor ,nall continue to run and purge heater cuing of residual heat until setting of fan override is reached, then the fan motor shall be deenergized. For those units with a fac- · tory installed two speed fan switch (25-50KW), the unit as shipped from the factory is set for the "low" sped fan position. Customer option to set to "high" speed. For .fflose units available with subdivided circuits, the ac- cassory two stage thermostat (optional) will, upon a call for heat, energize fan motor and the first stage heating element. Should temperature continue to fall, the ther- mosit shall energize the second stage heating element. Upon a rise in space conditions towards setting of file ther- mostat, the two stages of heating elements shall be deenergized in reverse sequence. The fan motor shall continue to run and purge heater casing of residual heat until setting of fan override is reached, then the fan motor shall be deenergized. The accessory unit mounted stratification thermostat will energize the unit heater fan motor upon a rise in at the same time the floor thermostat calls for heat, the mc '.or shall be energized immediately and the heating ele- ment shall be energized, as previously described. The automatic reset safety high limit shall dsenergize the heating elements and control circuits should the temperature exceed the setting of this device. The fan safety override shall energize fan motor any time the set- ting of this device is exceeded so as to purge heater cas- ing of excess residual heat. When the accessory fan switch is placed in the ON position (for summer air cir- culation), the unit heater fan motor shall be energized. NOTE: The wall thermostat is to be set to the OFF Posi- tion dudng this mode of operation (units with contactors). For films accessory the, ,, ~stats equipped with an integral fan switch, place the switch in the HEAT, or AUTO posi- tion for operation of file fan and elements which shall then be under control of the thermostat as described above. When switch is placed in the OFF position, the unit shall be dsenergized. When switch is placed in the FAN posk Uon, elements shall be deenergized and fan shall be im- rnediately energized. VERTICAL DISCHARGE UNITS -- AIR PATTERNS L~/Vll ~ ~ lltNQl/T BIR/IBI INII~IT&T ~ r ;I I' JI I: 1 t 11111 TABLE I MTG ITOCK I,I!~ON HT. A I NO. 3.3 & 5.0 KW' 9 20 10 STD 7.5 & 10.0 KW 12 40 22 STD ,15.0 & 20.0 KW 18 52 30 STD 25.0 & 30.0 KW 22 75 42 STD 40.0 & 50.0 KW 24 84 47 STD 9TD = Standard NIA = Not Applicable MAX, MAX. MAX. IrrG. MTG MI'G STOCK STOCK HEIGHT A lIT. A lIT. A NO. NO. dIS* OPEN 4~- OPEN 9 15 -- -- N/A NIA -- -- 12 30 10 30 AD5120 RD5120 0 14 36 30 18 40 15 38 AD5120 RD5120 14 21 42 35 22 55 17 50 AD5150 RD5150 20 30 62 44 24 64 20 60 AD5150 RD5150 18 28 68 64 Optional cliffusers lend added air pattern versatility to individual vertical down blow installations as shown in above illustrations. MOUNTING CLEARANCE '* '%*'12 " ° 'H ,: :, 8' Fig. I F;g. 2 HORIZONTAL DISCHARGE VERTICAL DISCHARGE 24" Frem Wile 4 3.3-SI('W 7.S-20KW i\ """" i \ .,- w ~ ~ I--- c>.-..I .,...,,.o. t/'2" K.O. 3/4" K.O. i"-'l" K.O. 1/2" K.O. WIG" K.O. ~-~-1" K.O. Fig. 3 DIMENSIONS (INCHES) KW H W D me. sc :~ · o ~_ 3.3.5.0 17-3/4 14-15/32 6-1/2 ii = 7.5, 10.0 24-5/16 21-1/2 6-1/2 ~: (~ "' ;~ - 15.0, 20.0 28-11/16 21-1/2 6-1/2 ii 25.0, 50.0 34 29-1/4 10-1/16 ~' :J .=-~ · ·'-'[;~''(4)%''Dia'' ' i /0 - v/\ °'\ A 9/16" K.O. ~" K.O. 1-11i-1~-2" K.O. 'For virtual mourning C VERTICAL DISCHARGE HORIZONTAL DISCHARGE . INSTALLATION INST~,CTIONS 5100 Series Unit Heaters All electric unit heaters are shipped fully assembled. In- stallation includes hanging the unit, mounting the built-in and remote accessories, wiring of optional control devices, and electrical wiring to the unit. o To insure proper delivery of the heated air to desired areas, follow the mounting height and air projection tables included in these instructions. Follow Fig. I & 2 for · minimum wall and ceiling clearances. The wall and/or ceiling structure must be sufficient to sup- port the combined weight of the heater and any mount- ing bracket and accessories. Be sure power source is de-energized before installing heater. Check heater voltage and phase listed on heater data tape on back of unit to make sure they are the same as the electrical service supplied. Certain units am adaptable from single to three phase ser- vice. Follow instructions noted on the unit wiring diagram for this conversion. Units that carry a dual voltage rating (HF) require specific wiring changes when converting from 240 to 208 volt service. Carefully follow the instructions on the unit wiring diagram. Open the access panel (2 1/4 turn fasteners). Remove the desired knock-out(s) on back of the heater. Install any optional accessories following their installation instructions before mounting unit. Following the correct unit/accessory wiring diagram, connect the power supp- ly, electrical ground and accessories to the correct ter- minals or termination points using accepted practices. NET JUNCTION BOX VOLUME KW CUBIC INCHES CC 3.3 - 5 74.4 1219 7.5 - 10 198 3245 15.0 - 20 198 3245 25.0 o 50 341 5592 Heaters may be mounted in the horizontal or vertical air discharge configuration using factory optional suppried ac- cessory mounting equipment or using special hardwere facilities supplied by others. After the installzp,~n ts complete, replace the access panel. Set the controls (thermostat, switch) at their desired con- trol point and apply power to the unit. Check for correct operation. HORIZONTAL AIR DISCHARGE MOUNTING Swivel hanger brackets may be used to suspend unit heaters from either the wall (Fig. 5) or the ceiling (Fig. 6). Attach hanger base "A" to top of heater with the four sAs x 18 cap screws and lockwashers (provided in envelope). Attach main hanger frame "B" to wall or ceiling in desired location using lag screws "C" or other suitable at- tachments (supplied by others). Lift heater into position inserting stud "D" through hole in main hanger frame and attach lock nut (provided in envelope) "E" tightening to within two tums of being tight. Swivel heater to desired position, tighten lock nut. VERTICAL AIR DISCHARGE MOUNTING (Fig. 7) Attach short angle brackets "A" to back of heater with four sAs x 18 capscrews "B", lockwashers "F". Be sure vertical leg of angle brackets face top and bettom of heater. Attach inverted U frames "D" to short angle brackets with four sAs x 18 capscrews "E", washere "F", lockwashers "G" and nuts "H". Attach long angle brackets "J" to inverted frames "D" with four sAs x 18 capscrews "K", washers "L", lockwashers "M" and nuts "N". Attach heater and bracket assembly to ceiling in desired location using customer supplied equipment sufficient to support the assembly. NOTE: When mounting heater using sAs" all thread rod (by others) do not screw the rod more than 1/2" beyond the inside of the case. 5100 SERIES TECHNICAL DATA ,~, TABLE 2 ELECTRICAL DATA HEATER/ CATALOG I(W BTU/HR MOTOR HEATER CONTROL NUMBER RATING (QQ0) VOLTAGE PHASE VOLTAGE F1 F5103 3.3 11.2 208 1 208 F2F5103 3.3 11.2 208 I 208 208 3 208 HF1 B5103 3.3/2.5 11.2/8.5 240/208 I 240/208 HF285103 3.3/2.5 11.2/8.5 240/208 I 240/208 240/208 3 240/208 G1 G5103 3.3 11.2 277 I 277 P3P5103CA1 3.3 11.2 480 3 24 FIF5105 5.0 17.1 208 I 208 F2F5105 5.0 17.1 208 I 208 208 3 208 HF1 B5105 5.0/3.7 17.111 2.8 240/208 I 240/208 HF2B5105 5.0/3.7 17.1112.8 240/208 I 240/208 240/208 3 2401208 GIG5105 5.0 17.1 277 I 277 P3P5105CA1 5.0 17.1 480 3 24 F2F5107CA1 7.5 25.6 208 I 24 208 3 24 HF2B5107CA1 7.5/5.6 25.5/19.2 240/208 I 24 240/208 3 24 GIG5107CA1 7.5 25.6 277 I 24 P3P5107CA1 7.5 25.6 480 3 24 F2F5110CA1 9.9 33.8 208 I 24 208 3 24 HF2B5110CA1 10.0/7.5 34.1/25.6 240/208 I 24 240/208 3 24 GIG5110CA1 10.0 34.1 277 I 24 P3P5110CA1 10.0 34.1 480 3 24 F3F5115CA1 15.0 51.2 208 3 24 HF3B5115CA1 15.0/11.2 51.2/38.4 240/208 3 24 P3P5115CA1 15.0 51.2 480 3 24 HF3B5120CA1 19.5/14.6 67.2/50.5 240/208 3 24 P3P5120CA1 20.0 68.3 480 3 24 F3F5125CA1 25.0 85.3 208 3 24 HF385125CA1 25.0/18.7 85.3/64.0 240/208 3 24 P3P5125CA1 25.0 85.3 480 3 24 F3F5130CA1 30.0 102.4 208 3 24 HB385130CA1 30.0/22.5 102.4/76.8 240/208 3 24 FvJP5130CA1 30.0 102.4 480 3 24 F3F5140CA1 40.0 136.5 208 3 24 HF385140CA1 40.0/30.0 136.5/102.4 240/208 3 24 P3P5140CA1 39.0 133.1 480 3 24 F3F5150CA1 49.6 169.9 208 3 24 HF3BB5150CA1 50.0/37.5 170.6/128.0 240/208 3 24 P3P5150CA1 50.0 170.6 480 3 24 · · · U3H5105CA4 5.0 17.1 600-240 3 240 U3H5107CA4 7.5 25.6 600-240 3 240 U3H5110CA4 10.0 34.1 600240 3 240 U3H5115CA4 15.0 51.2 600-240 3 240 U3H5120CA4 20 68.3 600.240 3 240 U3H5125CA4 25.0 85.3 600-240 3 240 U3H5130CA4 30.0 102.4 600-240 3 240 U3H5140CA4 40 136.5 600-248 3 240 U3H5150CA4 50 170.7 600-240 3 240 *'Use Copper Conductors on All Heaters *Use 75=C Wire "'NOTE: THIS UNIT (ONLY} BUILT IN 7.5 & 10KW CASE SIZE AMPS PER PHASE 15.9 15.9 9.2 13.7/11.9 13.7/11.9 7.9/6.9 11.9 4.0 24.1 24.1 13.9 20.9/18.1 20.9/18.1 12.1/10.4 18.1 6.1 36.1 20.8 31.3/27.1 18.1/15.6 27.1 9.1 47.8 27.8 41.6/36.1 24/20.6 36.1 12.1 41.7 36.1/31.3 18.1 47.6/41.1 24.1 69.5 60.2/52.1 30.1 83.4 72.3/62.5 36.2 111.2 96.4/83.4 47.0 139.0 125.6/104.3 60.3 5.1 7.7 10.2 15.5 20.3 24.5 29.4 39.8 49.4 BRANCH CIRCUIT PROTECTION raze (A) 20 20 15 2011 5 2011 5 10110 15 15 20115 15 15 80/70 110 100/80 150 126/110 175 176/150 15 15 15 25 35 50 SUPPLY WIRE S~E AWQ" 12 12 14 12/14 12/14 14/14 14 14 8 8 12 10/10 10/10 12/14 10 14 6 10 10/12 8 14 4 8 4/6 6/10 6 12 4 10 4/6 8 2 3/4 8 e 6 1/0° 1 '/2' 4 /0' 2/0ol/0 3 14 14 14 12 10 8 8 6 4 AIR D~LIVERY DATA TEMP. CFM et FPM at RISE OUTLET OUTLET "F HP 400 1030 26 1/125 400 1030 26 11125 400 1030 26 11125 400 1030 26 11125 400 1030 26 11125 400 1030 26 11125 400 1030 40 11125 400 1030 40 11125 400 1030 40 1 I125 400 1030 40 1 I125 400 1030 40 lJ125 400 1030 40 11125' 700 1000 34 1150 700 1000 34 1150 700 1000 34 1150 700 1000 34 1150 700 1000 45 1150 700 1000 45 1150 700 700 1100 1100 1100 1100 1100 2000/1800 200011800 200011800 200011800 200011800 200011800 310012800 310012800 310012800 310012800 3100/2800 310012800 558 700 700 1100 1100 2000/1800 200011800 310012800 3100~2800 1000 45 1150 1000 45 1150 1580 43 1120 1580 43 1120 1580 43 1120 1580 57 1120 1580 57 1120 130011 100 40144 111 2 130011 100 40144 111 2 130011 100 40144 111 5 130011 100 47~53 111 2 130011 100 47~53 111 2 130011100 47~53 1115 200011800 40145 114 200011800 40145 114 200011800 40145 114 200011800 51156 114 200011800 51156 114 200011800 51156 114 929 30 11125 1000 34 1150 1000 45 1150 1580 43 1120 1580 57 1/20 130011 100 40144 1/12 130011 100 47~53 1 I12 200011800 40~45 114 2000/1800 51156 114 FAN MOTOR DATA MAX IrrGo MOTOR HEIGHT RPM HOR VERT 1550 9 9 1550 9 9 1550 9 9 1550 9 9 1550 9 9 1550 9 9 1550 9 9 1550 9 9 1550 9 9 1550 9 9 1550 9 9 1550 9 9 1550 10 12 1550 10 12 1550 10 12 1550 10 12 1550 10 14 1550 10 14 1550 10 14 1550 10 14 1550 11 20 1550 11 20 1550 11 20 1550 12 18 1550 12 18 155011250 12 22 155011250 12 22 155011250 12 22 155011250 12 20 155011250 12 20 155011250 12 20 155011310 15 25 155~1310 15 25 155011310 15 25 155011310 15 22 155011310 15 22 155011310 15 22 1300 9 9 1550 10 12 1550 10 14 1550 11 20 1550 12 18 155011250 12 22 155011250 12 20 155011310 15 25 155011310 15 22 AIR THROW (HORIZ) 12 Ft. 12 Ft. 12Ft. 12 Ft. 12 Ft. 12 Ft. 12Ft. 12Ft. 12 Ft. 12 Ft. 12R. 12Ft. 22Ft. 22Ft. 22R. 22Ft. 22Ft. 22Ft. 22Ft. 32Ft. 32Ft. 32Ft. 32 Ft. 32Ft. 45Ft. 45 Ft. 45 Ft. 40Ft. 40Ft. 40 Ft. 55 Ft. 55 Ft. 55 Ft. 50 Ft. 50 Ft. 50 Ft. 12Ft. 22Ft. 22Ft. 32 Ft. 37 Ft. 45 Ft. 40 Ft. 55 Ft. 50 Ft. 25 25 25 25 25 27 25 25 25 25 25 27 50 50 50 50 50 50 50 50 65 65 65 65 65 120 120 120 120 120 120 120 120 120 120 120 120 50 50 50 65 65 120 120 120 120 TROUBLE SHOOTING CHART,~ ' SYMPTOM Thermostat calls for heat, }ut heater does not function POSSIBLE CAUSE(S) CORRECTIVE ACTION 1. Open (blown) fuse 2. INCORRECT WIRING 3. Thermal cut-out open, aleenergizing heater ele- ment and control circuit. Replace fuses, check for cause. (see Replacement Parts List for fuse size) CHECK WIRING CONNECTIONS * Check for the following: Correct supply volts & phase Correct control wiring (heater control must be thru thermostat control wiring section only) Power interruption to heater during heater operation Restriction of air around heater 1-5 minute fan purge after thermostat off =art motor runs "hot" 1. Dust accumulation or excessive dirt on motor 2. Dirt accumulation 3. Motor needs lubrication. 1. Clean fan motor end casing of grease and oil accumulation. 2. Clean Iouvers and between heating elements 3. See Maintenance. :an motor runs, but no heat. 1. Element contactor not operating correctly. 2. Element fuse blown. 1. Check widng for open circuit. Replace contactor if defective. 2. Replace fuses, check for cause. (See Replace, ment Parts List for fuse size.) MAINTENANCE CAUTION: Make certain that the power soume is discon- nected before attempting to service or disassemble any component. If the power disconnect is out of the line of sight, lock it in the OPEN position and tag to prevent the application of power, ELECTRICAL Once a year inspect the control panel wiring to make cer- tain insulation is intact and all connections are tight. In- spect all heater and relay contacts. If the contacts appear badly pitted or burned, replace the contactor/relay, For proper circuit protection during operation, the correct size fuse must be used, The parts list contains the fuse size for all units, 8 CLEANING Clean the unit casing, fen and motor once a year. A dirty motor will tend to run hot and eventually will be damaged internally. Any rust spots on the casing should be clean- ed and repainted. LUBRICATION NI units up to 20KW have fan motors that ere perrnaoently lubricated so that only occasional cleaning is required. Units above 20KW have fan motors lubricated for 5 years of continuous duty or 10 years of intermittent operation. When required, remove the oil access plug on back of heater at motor intake grill, open oil cap, fill with S.A.E. No. 10 electric motor oil, replace plugs and access plug· WIRING DIAGRAM SCHE~LE .DIAGRAM MODEL CODE NUMBER (PREFIX) WD5101 FIF-GIG-HFIB WD5104 GIG WD5106 F2F-HF2B WD5113 F2F WD5114 HF2B WD5138 P3P P3P WD5121 F3F WD5122 HF3B WD5125 F3F. F3F WD5126 HF3B HF3B WD5139 P3P WD5140 P3P WD5141 P3P WD5142 U3H WD5143 U3H MODEL CODE (SIZE AND CONTROL SYSTEM) 5103N 5105N 5107CALL 5110CALL 5103N 5105N 5107CALL 5110CALL 5107CALL 5110CALL 5103CAI N 5105CAI N 5110CAIN 5115CAIN 5115CALL 5115CALL 5120CALL 5125CAI L 5130CAI L 5150CALL 5125CALL 5130CALL 5150CNL 5125CAI N 5130CAI N 5140CAIN 5150CAIN 5105CA4N 5107CA4N 5115CA4N 5120CA4N 5125CA4N 5130CA4N 5150CA4N 5107CAI N 5120CAIN 5140CALL 5140CALL 5110CA4N 5140CA4N PARTS DRAWING lo ·. P~RTS LIST CATALOG NUMBERS REVISED 3191 POWER HEATER ELEMENT AUTOMATIC FAN TERMINN,. MODEL MOTOR ASSEMBLY ABET OVERRIDE XFMR CONTACTOR BLOCK F1F5103N 56562-012 60715-001 57640.006 56811-001 56815001 ~ F2F5103N 56562-012 60715-011 57640-006 56811-001 56815-001 HFIB5103N 56562-017 60715-002 57640.006 56811-001 56815-001 HF285168N 56562-017 60715-012 57640-006 568114301 56815-001 · GIG5103N 56562-016 60715.007 57640-006 56811-001 56815-001 P3P5103CAIN 56562-018 60715-008 57640.4)06 56811-001 60719-006 50378-016 56815-001 F1F5105N 56562-012 60715-003 57640.4306 56811-001 56815001 F2F5105N 56562-012 60715-004 57640-006 56811-001 56815-001 HF1B5105N 56562-017 60715-005 57640-006 568114)01 568154)01 HF2B5105N 56562-017 60715-006 57640.006 56811-001 56815-001 G 1 G5105N 56562-0 16 68715-009 57640-006 56811 .,001 568 15-001 P3P5105CAIN 56562-018 60715-010 57640-006 568114301 60719-(X)6 50378-016 56815-001 F2F5107CAIL 56823-011 56954-004 57640-003 568114)01 60719-001 50378-022 56816001 HF2B5107CAIL 56823-012 56954-006 57640-003 56811-001 65719001 50378-013 56816-001 GIG5107CAIL 56824-002 56954-001 576443.003 56811-001 60719-005 50378..013N 56815-001 P3P5107CA1N 56824-011 56954-002 576404303 568114)01 60719-006 50378.016 56815.001 F2F5110CAIL 56823-011 56954-003 57640.003 568114301 60719-001 50378-031 58816-001 HF2B5110CAIL 56823-012 56954-004 57640-003 568114)01 60719-001 50378-031 56816-001 G1 G5110CA1L 56824-002 56954-007 57640-003 568114)01 60719..005 50378022 56816001 P3P5110CA1N 56824.011 56954008 57640-003 56811-001 60719-006 50378-016 56815.001 F3F5115CA1L 56825-001 56954-009 57640.004 56811-001 68719-001 50378-031 56816-001 HF3B5115CAIL 56825-002 56954.010 57640-004 568114301 60719001 50378-022 56816-001 P3P5115CAIN 56825-003 56954-011 57640-004 56811-001 60719.006 50378-016 56815-001 HF385120CAIL '56825-002 56954-012 57640-004 56811,003 68719-001 503/8-031 56816-001 /""' P3P5120CAIN 568254:)03 56954-O13 57640-004 56811-003 60119-006 503784316 56815001 B.D. FUIE POWER FAN HEATER ELEMENT AUTOMATIC FAN BLOCK B.D. FUIE CONTACTOR TERMINAL 8litlED MOOEL MOTOR A88Y REIET OVERRIDE XFMR 2 Reid e I:IQD 2 Reid BLOCK 8W F3F5125CA1L 56943-00156954017 57640005 56811.002 60719009 50636012 41280.002 50378025 57097-001 57112001 HF385125CA1L 56943-002 56954018 57640005 56811..~,~: 60719009 50836-012 41280007 50378025 57097001 57112.001 P3P5125CAIN 56944-001 569544)19 57640-005 568114)02 65719-012 -- -- 50378.016 57098-001 57090.001 F3F5130CAIL 56943-001 56954-020 57640-005 56811-002 60719-009 50836.003 41280-008 50378-025 57097-001 571124)01 HF385130CAIL 56943-002 56954-021 57640-005 56811-002 60719-009 50836.012 41280-002 50378-025 57097-001 571124)01 P3P5130CAIN 56944-00156954-022 57640-005 56811-002 60719-012 -- -- 503784)16 57098-001 570904)01 F3F5140CAIL 56945-001 56954-023 57640-005 56811-002 60719-009 508364)03 41280-004 50378.025 57097-O01 571124)01 HF3B5140CAIL 56945-002 56954-024 57640-005 56811-002 60719-009 50836-003 41280-003 50378.025 57037-001 57112-001 P3P5140CAIN 56946-00156954-025 57640-005 56811-002 60719-012 -- -- 503784)16 57098-001 57090-001 F3F5150CAIL 56945-00156954..026 57640-005 56811.003 65719-009 508364X)3 41280.005 50378-034 57037.001 57112-001 HF3B5150CAIL 56945-002 56954-027 57640-005 568114)03 60719-009 508,16-003 41280-004 503784)25 57097-001 57112.OO1 P3P5150CA1N 56946-001 56954-028 576404)05 56811-003 60719-012 57110-001 571114)08 50378-016 57037-001 57090.001 FAN TERMINAL GROUND MOTOR ~ BLAOE BOARD CORN. CAPACITOR LOUVER 3.3-5 56806-001 56809.001 1458 -- (5) 56986-001 7.5-10 51554-002 56809-001 1458 -- (7') 56986-003 15-20 56813.001 56809-001 1456 -- (7') 56686-003 25-30 57114.-001 56809-001 3981 57100-001 (9) 56987-001 40-50 57115.O01 56809-001 3981 57100-001 (9) 56887-001 11 PARTS UST -- I00 VOLT MODELS U3H5105CA4N U3H5107CA4N Motor 56562-017 56823-012 Eienmt Assy. 5~gEI.02g 569H 030 Auto, Reel Umjt 57640003 576404)03 Fin Oven'Me S6811.001 56811-001 XFMR 57S41.003(100VA) 57641.001(150VA) Cometlot 503/8-018 503784) 18 Fen Blmle 61554-4X)2 61554-002 Temenel Boerd MB00-001 r~809.001 U3H5110CA4N 56823-012 56954-031 676404)03 5~811-001 5'76414)01 503/8-,018 r~815-001 616~14302 14~8 HBBB U3H51:SCA4N U3H5130CA4N U3HS140CA4N 65g13 092 ~1~ ~1~ ~1~1 58888 ~1~ ~11~ ~1~ ~12~1 U3H5115CA4N 56825-0O2 676404)04 56811-001 57641-(X)2(300VA) 50378.018 ~6815.001 56813-001 50800-001 aweas I.laHSlm 58015 Me54.037 sTe4o.oos seell~xs3 57841.004 5o37~o18(2) 57oe6.ool 67115~01 Neoe. ool 3991 Hge! 67844o01(;) 571124)01 U3HS120CA4N 5682[ 002 56954 035 568114)03 ,57641.002 50378-018 5~815.001 M813.001 M80~001 ' 1488 68888 003(7) rr~ TPI C4~mrat/~n LIMITED WARRANTY I:modm:m~byTPICo,,x,,~llonereeerramedloa eiglnel~oneumertobefreefmmdefeleinmmerlalendwofianen- efebrtweve(~2) rnore~fmmmeeigeWUmdpun:tme. Th, cYalr fllrl rald volllge, llxlo111i ulagl, (ll~y ir _ ' Ioplovide flugOes!ill ~ IxoGedulree efldoeed wiDl the ixodu~impfoermaintefaneorenympebsoewewleem OF TPI CORPORATION FOIl CONSEQUENTIAJ. DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE USE OR PERFORUANCE OF THE PFKX)U~r OR OTHER INDIRECT DAMAGES WITH RESPECT TO LOSS OF PROPERTY, REV- ENUES, OR PROFrT, OR COS~. OF REUOV~, INSTALLATION ALL HIPLIED WARRANTIES WTTH RESPECT TO TPI PROD- UCTB, INCLUDING IMPUED WARRANTIES FOR MERCHANT- ABILITY AND IMPUED WARRANTIES FOR FITNESS, ARE LIMITED IN DURATION TO TWELVE (12) MONTHS FROM ORIGINAL DATE OF PURCHASE, EXCEPT THOSE FRODUCTS OR PARTS OF PRODUCTS WHICH ARE WARRANTED FOR L~ PERIODS. ON SUCH PRODUCTS OR PN:!TS OF PRODUCTS ALL IMPLIED WARRANTIES FOR MERCHANT;L- ITY AND FITNESS ARE LIMITED TO THE DURATION OF THE EXTENDED WARRANTY PERIOD THEREON. TP! Corporation rRO. Box4973 Johnson City, TN 37602 (423)477,4131 (423)477-oo64 8memm'donotdowlheeadudonorlndetmolinctdenalor corsl que~.ir" damagel end eome eatBe dD not Mow Indtatioa on howlong in lmpkd wemmylMm. eoNNmveem:~e~:naor DumglNeewee/lado~.TPICc, pcafonMII. alleemeol~let. prelxld, lolETPI Cra~xa~l~nfacloWorBuchmherlomenmTIN C~o. all:nnmym. Rmum~lim/~mnmml~!w~a~d numberottheproductendnmumofdHtxanybeing,'~'~lin;ad lNewermmydoeenotobigelTPICoqxNllontollerlmooltol mlxinmling or remo~,F-reightorclemaga. Them MII beduegeemndoredb'l:~ductmpeimmedoabr,ourwen'mUY peexl~.-dexpered. F, rodofpureme.'etUuengUm. mue Co,~r.. ";n'smaxlmmklltystWlnmlnanyweemadml8 ixice exme lxoe~ckinedm be defecee. Thie wemmy glvem you epedl~ legal dglls end you may heve mher ~lm which may veylrommmtomm. Foreenemeofyourneremin"v,,"-ed P.O. b,N73, Jotmeon Cily, Tenneeae, 378)2.. IneddltiontoNUmltedWirrantyemedetove~ove~genetl Iis~pmdum, wNchamwwran~lommlginlconaumlmm 1,BlmlllllnllllmlllFIiiMde aOelelMeNeHmefBemem lom I. Ikmme mlememe I. Bememl, walNmm l~ef 4. MQlePlmlme 11me Form 9632 TPI Corpora~ion (USA) JOHNSON CITY. TN 376024973 SERIES 5100 Montage horizontal ou vertical radiateur industriel et commercial INSTRUCTIONS D'INSTALLATION ET LISTE DE MATERIEL ATTENTION: LISEZ LES INSTRUCTIONS SOIGNEUSEMENT AVANT DE COMMENCER L'INSTALLATION, LA MISE EN MARCHE OU L'ENTRETIEN DU RADIATEUR TASKMASTER. GARDEZ ,CES INSTRUCTIONS POUR UTILISATION ULTERIEURE. CARACTERISTIQUE$ Radiateur eilectrique avec ventiiateur, disponible suivant les tensions standards de 208, 240/208, 277, 480 ou de Dix puissances de chauffage standard de 3.3 KWI11,260 BTUH jusclu'b 50.0 KWI170,600 BTUH. Les roodhies unipoiaires de 3.3 jusqu'b 10.0 KW de 208 et de 240/208 volts peuvent se transformer sur le chart- tier en roodhie tripolaire. (les roodhies unipolaires de 3.3, 5.0, 7.5 et 10 KW de 277' volts ne peuvent Nre transforrmbs). Le volet int~rieur sl~cialernent conCu permet au ven- tilateur d'appeiar I'air uniform~bment A travers I'~leiment massif en aciar. Le diffuseur con~;u vers I'exteirieur et les volets monteis dirigent plus encore uniform~bment la propulsion de Fair a~n de r~pondre aux exigences speicifiques du montage horizontal ou vertical de I'appareil. Supports de montage murlplafond ou verticaux en option. (cornroe requis). T Quatre eicrous soudeis sont disposes au dessus et ~, I'arribre du boltier pour le montage de I'appareil au chan- tier avec des tiges fileMe ou des boulons avec chine. (vissede foumie par d'autres). Diffuseur ambmostat ou radial (en option), donnant une propultion d'air diversi~eie Iors du montage vertical de I'appareil. Instruments de contrOle varieis pour installation sur le chantiar. Interrupteur, thermosit, interrupteur du yen- tilateur pour la saison astivale, thermostat pour nbcu;xbra- tion de chaleur. Tous ont leurs conducteurs eiquipl~s de serre-fils A lame. (A I'exception de I'interrupteur) Tableau de branchement de la ~lerie de tousles in- struments de contrble inteigr~s, en un seul endroit. Circuit de contr01e standard basse tension de 24 volts sur tousles modbles avec transformateur ou. contracteur. Boite de contrble spacieuse ayant une porte d'accbs fermeie ~ I'aide de deux attaches 1/4 de tour pour rendre I'installation facil~,~ INSTRUCTIONS POUR UN EMPLACEMENT CORRECT Une fois que la charge totale de chauffage est calcul~be, le nombre et la puissance des radiateurs doivent ire determimbs. Un grand nombre de radiateurs b faible puissance donnent une rdpartition de chaleur uniforme; cette solution est recommand~be Iorsque la surface sara occul~e par un nombre relativement 61ev~t de personnel sebdentaire, travaillant beut ire sur des lignes de produc- tion ou sur des bancs. Un nombre ~blev~ de radiateurs de plus faible puissance ont tendance b p~venir des courants d'air chauds, b r~duire le niveau du bruit, et~ augmenter la rbpartition de la charge afin d'aider t!i niduire la demande en ~blec- tricit~ et les coots d'opibration. Dens les entrepbts o(l la ~partition de la chaleur et une tempibrature censtante sont tooins importantes, un plus grand nombre de radiateurs ~, haute puissance peuvent btre utilimbs; dens bien des cas r~bduisant ainsi les coots d'origine. Afin de malntenir une rbpartition de chaleur raisonnable et r~duire de mbvbres stratifications m~me dens les endroits o(s le piefond est plus bas, le volume d'air total de tout I'espace doit passer b travers le radiateur ~ peu pr6s trois fois par heure. (divisez par 20 le volume total en pieds cubes afin de determiner le debit total en PCM des radiateurs). II est important que le tension nominale de I'tbquipement de chauffage soit la mitre que celle de I'alimemation de courant. La tension de ceurant en excb de la tension nominale du radiateur peut endommeger I'~quipement. La tension d'alimentation plus basse que calle de la ten- sicn nominale du radiateur diminuera la puissance de celui-ci et en meme temps vous prendrez le risque d'en- dommager les pibces. Les radiateurs horizontaux sont recommandes pour les endroits ou les plafonds sont bas (maximum de 15 b 18 pieds). Ces radiateurs devront ~tre cencenmbs le long des murs donnant sur I'ext~rieur ou sur d'autres endroits o~ il y a de grandss bertes de chaleur, espacebs a~n d'obtenir Un mouvement d'air circulaire, chaque radiateur accep- tant+i'air propulmb par I'autre. Des radiateurs verticaux suppl~bmentaires propuisant I'alr vers le bas avec des dif- fuseurs appmpri~s peuvent ire install6s pour con- trebalancer les pertes de chaleur au piefond. RENSEIGNEMENTS GENERAUX SUR LA SECURITE ATTENTION: Suivez tousles codes Ioceux d'eblectdcit~b et sur la securit~b, NEC, OSHA et I'ACNOR. Afin d'eviter les chocs 61ectriques possibles, s'assurer que le ceurant ~lectrique est coul~ au niveau de I'interrupteur principal event le filage ou I'entretien de I'appamil. Si I'interrupteur de I'alimentation n'est pas inffigreb et si il n'est pas visible, verrouillez-le en position "ouvert" et 6tiquettez-le afin d'empe~her une fermeture de courant inattendue event que I'on fasse I'entretien de I'appareil. Quand I'appamil est installfb il doit ~tre ~blectriquement mis b la term en accord avec NEC, les ussages standards de I'industrie et I'ACNOR. S'assurer que I'alimentation est conforme aux exigences de votre ebquipement. Voir la table 2 pour se renseigner sur le calibre du fil conducteur, I'intensitb du circuit, etc. V~bri~ez la tension et I'ordre des phases du radiateur sur sa plaque de caract~ristiques afin de s'assumr qu'ils sont les m~mes que ceux de I'alimentation 61ectrique. Les sh~bmas de filede des radiateurs et les connections de I'alimentation sont en permanence ~ I'intbrieur de la porte d'acctm du radiateur. Toutes les bornes sont mar- qutbes conformebment avec le sh~bma de filerie. Le ~age des accessoims est mon~ sur le shame de filede de I'ap- pareil et sur la documentation le concernam. Le radiateur dolt ire mont6 au moins b 8' au dessus du plancher afin d'empbcher un contact accidentel avec les ailettes du ventilateur pourant occasionher des blessures. Installez I'appareil de fa{;on bce qu'il n'y ait aucune obstruction b I'entr~e ou b la sortie. Maintenir les dimen- sions indiqu~bes sur les tables I & 2, Fig. I & 2. . Le support de montage murlplafond et les provisions pour I'ancrage doivent btre assez r~sistants pour supporter le poids combimb du radiateur et du support. PRINCIPES DE FONCTIONNEMENT Si le thermostat integre du radiateur (en option) ou celui qui est instalkb sur lemur est excite, le moteur du ven- tilateur de I'appareil et les elements de chauffage seront mis sous tension et le resteront jusqu'b ce que la temrHbrature atteigne le nbglage du thermostat; b ce mo- ment, les elements de chauffage seront mis hors tension. Le moteur du ventilateur continuera de toumer et d~bgagera ainsi la chaleur emmagasirNbe darts le boTtier jusqu'b ce que le reglage de derogation du ventilateur soit attsint; des Iors, le moteur du ventilateur ne sera plus sous tension. Les appareils avec un interrupteur de ventilateur b deux vitesses installe ~ la fabrique (25 - 50 KW), seront exlmbdies avec les ventilateurs reghbs sur la "petite" vitesse. Le client ale choix de les r~gler sur la "grande" vitesse. Pour les appareils disponibles avec des circuits sepanbs, le thermostat A deux r~glages (en option) devra, quand on le fermera, mettre sous tension le moteur du ventilateur et I',bl~ment de chauffage de premibre phase. Si la teml~bratura continue de tomher, le thermostat met- tra sous tension I'elebment de chauffage de deuxibme phase. Le courant des deux phases des elements de chauffage sera coul~ en sequence inverse Iorsque la teml~bratura s'elbvera jusqu'au r~glage du thermostat. Le moteur du ventilateur continuera de toumer et degagera ainsi la chaleur emmagasinee dane Is boitier jusqu'b ce que le r~glage de derogation du ventilateur soit atteint; des lore, le moteur du ventilateur ne sera plus sous tension. Le thermostat de stratification monte sur I'appareil met- tra sous tension le moteur du ventilateur jusqu 'b ce clue la APPAREILS A PROPULSION D'AIR VERTICALE temp&ratura s'elbve au-dessus de son rbglage. Lorsque le thermostat de stratification monte se ferme quand la teml~bratura s'elbve et qu'au mbme moment le ther- mostat mural se ferme aussi, le moteur du ventilateur et I'element de chauffage seront mis sous tension immediatement, comme decrit plus haut. La limite maximum de securite du r~enclenchement automatique coupera le courant alimentant les dhbments de chauffage et les circuits de contr(}le Iorsque la teml:Nbrature s'elbvera au-dessus du reglage de ce dispositif. La ddrogation de sebcudffi du ventilateur devra mettra sous tension Is moteur du ventilateur chaque fois que Is nbglage de ce dispositif est alepasse a~n de d~gager ainsi la chaleur emmagasimbe clans le boTtier. Lorsque I'interrupteur du ventilateur set plac~b sur la position "MARCHE" (pour la saison d'btd), le moteur du ven- tilateur sera alimentd. NOTE: Le thermostat mural doit Nra rdgl6 b la' position "ARRET" durant ce type d'ol:~rations (apparails munis de contacteurs). Pour les thermostats ~bquipl:~s avec un interrupteur de ventilateur int~gr~, placez I'interrupteur A la position "CHALEUR" ou A la positoin "AUTO" afin de faire fonc- tionner le ventilateur et les ~kiments qui seront sous le contrOle du thermostat comme d~bcrit plus haut. Lorsque I'interrupteur est plaub b la position "ARRET", I'alimen- tation de courant de I'appareil devra ~tre coul~e. Lors- que I'interrupteur sera b la position "VENTILATEUR", I alimentation de courant des ~lements sera coul~e et le ventilateur sera imm6diatement mis sous tension. -- MODELES /,/ laNllllvtmmm OlFFUSBU~NeBIOSTAT aiMgiN. TABLE I HAUT. HAUT. HAUT. HAUT. MAX. MAX. NO. DE MAX. MAX. NO. DE NO. DE DE lIONTAM A UIED ON MONT. A B ITOQ( MONT. A MONT. A 8TOClC 8TO(~C 41* OUVERT 41" OUVERT 3.8 & 5.0 KIV 2rn747 6m105 3m052 STD 2m747 4M579 -- -- N/A NIA 7.5 & 10.0 KW 3m663 12m211 6m716 STD 3rn663 9m158 3m052 9m158 AD5120 RD5120 0 4m273 10m990 9m158 15.0 & 20.0 K1N 5m495 15m874 9m158 STD 5m495 12m236 4m579 11m600 AD5120 RDS120 4m273 6rml,10 12m821 10m684 25.0 & 30.0 KVV 6m716 22m896 12m821 STD 6m716 15m790 5m189 15m264 AD5150 RDSISO 6m105 9m158 18m927 13m432 40.0 & 50.0 KW' 7m326 25m643 14m348 STD 7m326 19m537 6rn105 18m316 AD5150 RD5150 5m495 8rn547 20m759 16m485 STD = StandarcI NIA - Not Appliquehie ~es diffuseurs (en option) donnent une propulsion d'air supplementaira aux installations ~ sortie d'air verticale. Voir les illustrations ci-dessus. % e'(2m442) DBTANCE5 DE MONTAGE 8' (2m442) 2' t 'POUr 7.540 KW 18' (4~7) clu pldond 24° (~10) dee mum FIg. 2 PROPULSION VERTICALE b w ,4 -41--D-.-.-.4 KW H W D 3.3, 5.0 451 367 165 7.5, 10.0 618 546 165 15.0, 20.0 729 546 165 25.0, 50.0 864 743 256 3.3-SKW Fig. 3A : · '4"' K.O,~ 0/ '~,"' K.O. ,I,," K.O. 7.S-20KW Fig. 3C 25-SOKW ~ .~ :~ _= 9111" K.O. :,t" K.O. 1-1Ye-1 t/t-2" K.O. F~.S fig. 7 MONTAGE AU PLAFOND MONTAGE &U PI.AFOND PROPULSION HORIZONTALET ~ PROPULSION VERTICALE T' "1 INSTRUCTIONS D'INSTALLATIONS Radlateurs setrles 5100 Tousles radiateurs eblectriques sont expebdiebs complbtement montebs. L'installation comprend la suspen- sion de I'appareil, le montage des accessoires incorpords ou de commaride A distance, la filerie des dispositifs de contrble (en option) at la filede dlectrique de tout I'appareil. Afin de s'assurer que I'air chaud se propage aux endroits voulus, consultez les tables relatives aux distances de montage et b la propultion de I'air incluses dans ces in- structions. Voir les Fig. I & 2 pour les distances maintenir de I'appareil au tour et au plafond. La structure du mu et/ou du plafond dolt etre assez solide afin de supporter le poids cornbind du radiateur, de ses supports et de ses accessoires. S'assurer que le courent d'alimentation soit coul~ avant d'installer le radiateur. Vbrifiez la tension et I'ordre des phases du rediateur inscrits sur la plaque de caractd~risti- ques de ce dernier ~ I'arribre de I'appareil afin de s'assurer qu'ils soient les m~imes que ceux de I'alimen- tation de courant. Certains appareils unipolaires peuvent se transformer en appareil tripolaire. Suivez les instructions inscrites sur le shema de filerie de I'appareil pour cette conversion. On dolt modifier la illerie des appareils ayam une tension dou- ble (HI:) si on veut changer la tension de 240 b 208 volts. Suivez soigneusement les instructions du shema de filerie de I'appamil. Ouvrir la porte d'accbs (2 attaches 1/4 de tour) Enlevez les rondelles deifon{;ables que vous avez choisi b I'arribre du radiateur. Installez les accessoires (en option) en suivant les instruc- tions b leur sujet avant de monter I'appareil. Suivant le bon shema de filerie de I'appareii et de ses accessoires, branchez I'alimentation de courant, la raise b la terre et les accessoires aux bomes correspondantes ou aux points de branchemont en utilisant les pratiques d'usage. Volume De La Boite De Jonction KW Pouces Cartea CC 3.3 - 5 74.4 1219' 7.5-10 198 3245 15.0 - 20 198 3245 25.0 - 50 341 5592 Les radiateurs peuvent ~tre montebs la propulsion d'air ebtant horizontale ou verticale en utilisant libquipement de montage des accessoires (en option) de la fabdque ou en utilisant de la visserie fournie par d'autres. L'installation finie, replacez la porte d'accbs. Re}glez le thermostat et I'interrupteur au point clesir~ puis mettez I'appareil en marche. Vedfiez si le fonctionnement du radiateur est correct. MONTAGE AVEC PROPULSION D'AIR HORIZONTALE Les supports de suspension b pivot peuvent Nre utilis~s afin de suspendre les mdiateurs au mur (Fig. 5) ou au pla- fond (Fig. 6). Montez la base de soutien "A" au dessus du radiateur avec les quatres vis de sac x 18 et les rondelles d'arret (dans I'enveloppe). Fixez le support de suspension principal "B" au mur ou au plafond ~ I'emplacement ddsir~ en utilisant les tire- fonds "C" ou des pieces de fixation addquates (foumies par d'autres). Soulevez le radiateur, faites rentrer la tige "D" dans la trou du support de suspension principal et vissez I'~tcrou de blocage "E" (dans I'enveloppe) jusqu'b ce qu'il soit b deux tours d'btre serre. Faites pivoter le radiateur b la position d~sin~ puis serrez I'ecmu de blockage. MONTAGE AVEC PROPULSION D'AIR VERTICALE (Fig. 7) Fixez les petites comibres "A" b I'arribre du radiateur avec quatre vis de sA. x 18 "E", et les rondelles d'ambt "F". S'assurer que I'aile perpendioulaire des comibres fait face au dessus et au dessous du rediateur. Fixez les cadms en U "D" aux petites comibres avec quatre vis de sac x 18 "E" , les rondelles "F" , les rondelles d'arret "G" et les e~crous "H". Fixez les gmndes comibres "J" aux cadres en U "D" avec quatre vis de sAa x 18 "K", les rondelles "L", les rondelles d'arrbt "M" et les e~cmus "N". Fixez le rediateur et son support month au plafond, b I'emplacement d6sird en utilisant un bquipement assez robuste pour le supporter, foumi par le client. NOTE: Lorsque vous montez le rediateur en utilisant des tiges filet~es de sAs" (par d'autres), ne pas visser la tige de plus de 1/2" ~ I'int~rieur du bo*~ier. CARACTERISTIQUES TECHNIQUES DES SERIES 5100 TABLE 2 CARACTERISTIQUES ELECTRIQUES TENSION NUMERO DE PUISSANCE BTU/HR MOTEUR CATALOGUE EN KW (000) RADIATEUR F1 F5103 3.3 11.2 208 F2F5103 3.3 11.2 208 208 HF1 B5103 3.3/2.5 11.2/8.5 240/208 HF2B5103 3.3/2.5 11.2/8.5 240/208 240/208 G1 G5103 3.3 11.2 277 P3P5103CA1 3.3 11.2 480 FIF5105 5.0 17.1 208 F2F5105 5.0 17.1 208 HFIB5105 5.0/3.7 17.1112.8 240/208 HF2B5105 5.0/3.7 17.1112.8 240/208 240/208 G1 G5105 5.0 17.1 277 P3P5105CA1 5.0 17.1 480 F2F5107CA1 7.5 25.6 208 HF2B5107CA1 7.5/5.6 25.5/19.2 240/208 240/208 G 1 G5107CA1 7.5 25.6 277 P3P5107CA1 7.5 25.6 480 F2F5110CA1 9.9 33.8 208 208 HF285110CA1 10.0/7.5 34.1125.6 240/208 240/208 GIG5110CA1 10.0 34.1 277 P3P5110CA1 10.0 34.1 480 F3F5115CA1 15.0 51.2 208 HF3B5115CA1 15.011 1 o2 51.2/38.4 2401208 P3P5115CA1 15.0 51.2 480 HF3B5120CA1 19.5/14.6 67.2/50.5 240/208 P3P5120CA1 20.0 68.3 480 F3F5125CA1 25.0 85.3 208 HF3B5125CA1 25.0/18.7 85.3/64.0 '2401208 P3P5125CA1 25.0 85.3 480 F3F5130CA1 30.0 102.4 208 HB3B5130CA1 30.0/22.5 102.4/76.8 2401208 P3P5130CA1 30.0 102.4 480 F3F5140CA1 40.0 138.5 208 HF3B5140CA1 40.0/30.0 136.51102:4 2401208 P3P5140CA1 39.0 133.1 480 F3F5150CA1 49.6 169.9 208 HF3BB5150CA1 50.0/37.5 170.6,/128.0 2401208 P3P5150CA1 50.0 170.6 480 · .-U3H5105CA4 5.0 17.1 600-240 U3H5107CA4 7.5 25.6 600-240 U3H5110CA4 10.0 34.1 600-240 U3H5115CA4 15.0 51.2 600-240 U3H5120CA4 20 68.3 600-240 U3H5125CA4 25.0 85.3 600-240 U3H5130CA4 30.0 102.4 600-240 U3H 5140CA4 40 136.5 600-240 U3H5150CA4 50 ~ 7A~ **Use Copper Conductors o eaters '[ PROTECTION TENSION INTENIITE DU CIRCUIT DE EN AMP. DE BRANCH. PHASE CONTROLE PAR PHASE CALlIRE(A) I 208 15.9 20 ~1 ', 208 15.9 20 3 208 9.2 15 1 2401208 13.711 1.9 2011 5 I 2401208 13.711 1.9 2011 5 3 2401208 7.916.9 10110 I 277 11.9 15 3 24 4.0 15 I 208 24.1 35 I 208 24.1 35 3 208 13.9 20 I 240/208 20.911 8.1 30125 I 240/208 20.911 8.1 30/25 3 240/208 12.1110.4 20115 I 277 18.1 25 3 24 6.1 15 I 24 36.1 50 3 24 20.8 30 I 24 31.3/27.1 40135 3 24 18.1115.6 25/20 I 24 27.1 33 3 24 9.1 15 I 24 47.8 50 3 24 27.8 33 I 24 41.6/36.1 50150 3 24 24/20.8 30130 I 24 38.1 50 3 2~. 12.1 20 3 24 41.7 50 3 24 38.1/31.3 50140 3 24 18.1 25 3 24 47.8/41.1 60150 3 24 24.1 38 3 24 68.5 90 3 24 60.2/52.1 80/70 3 24 50.1 40 3 24 83.4 110 3 24 72.3/62.5 100180 3 24 38.2 50 3 .24 111.2 150 3 24 96.4/83.4 125/110 3 24 47.0 60 3 24 139.0 175 3 24 120.51134.3 1751150 3 24 60.3 80 3 240 5.1 15 3 240 7.7 15 3 240 10.2 15 3 240 15.5 20 3 240 20.3 25 3 240 24.5 35 3 240 29.4 40 3 240 39.8 50 · "'~9.4 60 600-240 3 240 *Use 75°C Wire CALIBRE CU CONDUCTF,,UR D'AUM. e0"C A'WG" 12 12 14 12/14 12/14 14/14 14 14 8 8 12 10/10 10/10 12/14 10 14 6 10 10/12 8 14 4 8 4/6 5/10 6 12 4 6,/8 10 4/6 8 2 3/4 8 2' 6 1/0' 1 '/2' 4 2/0'1/0' 3 14 14 14 12 10 8 8 6 4 , · ~RTIE CARACTERISTIQUES DE LA PROPULSION DE L'AIR ELEV. DE LPM & 18 TEMP. DE SORTIE L'NR *F CV 1030 26 1/125 1030 26 1/125 400 1030 26 11125 400 1030 26 1 I125 400 1030 26 11125 400 1030 26 11125 400 1030 40 11125 400 1030 40 11125 400 1030 40 11125 400 1030 40 11125 400 1030 40 11125 400 1030 40 11125 700 1000 34 1150 CARACTERISTIQUES DU MOTEUR DU VENTILATEUR HAUTEUR AIR RPM DU MAX. DE MONT. PROPULSE MOTEUR HOR. VEFIT. (HORIZ) 1550 2m747 2m747 12 FT. 3m658 1550 2m747 2m747 12 FT. 3m658 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 1550 700 1000 45 1150 1550 700 700 1100 1100 1100 1100 1100 200011800 200011800 200011800 200011800 2(X)011800 3100/2800 3100/2800 310012800 310012800 310012800 3100/2800 558 700 700 1100 1100 200011800 200011800 3100~2800 310.012800 2m747 2m747 12 FT. 3m658 2m747 2m747 12 FT. 3m658 1000 45 1150 1000 45 1150 1580 43 1/20 1580 43 1/20 1580 43 1/20 1580 57 1/20 1550 57 1/20 130011100 40144 1112 130011100 40144 1112 130011100 40144 1115 130011100 47153 1112 1300/1100 47153 1112 130011100 47153 1115 200011800 40145 114 200011800 40145 114 200011800 40~45 114 200011800 51/56 114 200011800 51156 114 200011800 51/56 114 929 30 11125 1000 34 1150 1000 45 1150 1580 43 1/20 1580 57 1120 130011 100 40144 1 I12 130011100 47~53 1112 2000/1800 114 2m747 2m747 12 FT. 3m658 2m747 2m747 12 FT. 3m658 2m747 2m747 12 FT. 3m658 2m747 2m747 12 FT. 3m658 2m747 2m747 12 FT. 3m658 2m747 2m747 12 FT'. 3m658 2m747 2m747 12 FT. 3rn658 2m747 2m747 12 FT. 3m658 3m052 3m663 22 FT. 6m705 3m052 3m663 22 FT. 6m705 3m052 3m663 22 FT. 6m705 3m052 3m663 22 FT. 6m705 3m052 4m273 22 FT. 6m705 3m052 4m273 22 FT. 6m705 1550 3m052 4m273 22FT. 6m705 1550 3m052 4rn273 22 FT. 6m705 1550 3rn358 6m105 32 FT. 9m754 1550 3m358 in105 32 FT. 9m754 1550 3m358 6ml 05 32 FT. 9m754 1550 3m663 5m495 32 FT'. 9m754 1550 3m663 5m495 32 FT. 9m734 1550/1250 3m663 6m716 45 FT. 13m716 15,5011250 3m663 6m716 45 Ft. 13m716 155011250 3m663 6m716 45 FT. 13m716 1550/1250 3m663 6m105 40 FT. 12mlli 155011250 3m663 6m105 40 FT. 12m192 155011250 3m663 6m105 40 FT. 12m192 155011310 4m579 7m632 55 FT. 16m764 155011310 4m579 7m632 55 FT. 16m764 155011310 4m579 7m632 55 FT. 16m764 1550/1310 4m579 6m716 50 FT. 15m240 155011310 4m579 6m716 50 FT. 15m240 155011310 4m579 6m716 50 FT. 15m240 1300 2m747 2m747 12 FT. 3m658 1550 3m052 3m663 22 FT. 6m705 1550 3m052 4m273 22 FT. 6m705 1550 3m358 6m 105 32 FT. 9m754 1550 3m663 5m495 32 FT. 9m754 155011250 3m663 6m716 45 FT. 13m716 155011250 3m663 6m105 40 FT. 12m192 155011310 4m579 7n',~,,~ 55 FT. 16m764 155011310 4m579 6n. 3 50 FT. 15m240 POIO$ LIS. KG. 25 11.4 25 11.4 25 11.4 25 11.4 25 11.4 27 12~ 25 11A 25 11A 25 11.4 25 11~ 25 11.4 27 12.3 50 22.7 50 22.7 50 22.7 50 22.7 50 22.7 120 54.60 120 54.60 5O 22.7 50 32.7 50 22.7 65 29.60 65 29.60 120 54-60 120 54.60 120 54.60 120 54.60 TABLEAU DES PANNES SYMPTOMES Le thermostat est excitb mais le radiateur ne fonc--,- tionne pas CAUSE(S) POSSIBLE(S) 1. Le fusible a saut~ FILERIE INCORRECTE Le coupe-circuit thermi- que est ouvert coupant le courant b I'~blbment du radiateur et du cir- cuit de conlnSle. MESURES DE CORRECTION 1. Remplacez les fusibles, cherchez la cause de'r panne (volt la liste des pibces de rechange pet,. I'intensitb des fusibles). 2. VERIFIEZ LES CONNECTIONS DES FIL~ CONDUCTEURS e V~ri~ez ce qui suit: , La tension et I'ordre des phases de I'alimentation. La ~lerie de corerhie (le contr~le du radiateur doit per par la filede de cotr01e du thermostat seulement. Interruption de I'alimentation du radlateur durant son fonctionnement, Manclue d'air autour du radlateur. Aprbs I'ouverture du thermostat faites toumer le moteur du venti- lateur pendant I i 5 minutes afin de dt~gager la chaleur ainsi emmagaisimrm, Le moteur du ventilateur "chauffe". AccumulaUon de peussibre ou sNete ex- cessive sur le moteur. Accumulation de sNet~. Le moteur a besoin d'ire lubrifl. 1. Nettoyez les accumulations de graisse et d'huile du moteur du ventilateur et du boNer. 2. Nettoyez les volals chauffage. 3. Voil I'entretien. et entre les ~kiments de Le moteur du ventilateur toume mais il n'y a pas de chauffage. 1. Le contacteur de 1. 1'6lemem ne fonctionne pas correctement 2. Le fusible de I'~tldment 2. a saut~ V~rtfiez s'il n'y a pas un circuit ouvert dens la file ' Si le contacteur est debfectueux remplacez-le. ~ Remplacez les fusibles, cherchez la cause de la panne (voir la liste des pibces de rechange peur I'intensit~ des fusibles), A moins d'un cas d'urgence, n'ouvrez pas I'interrupteur principal iorsque le radlateur fonctionne. II se peurrait que le coupe-circuit thermique s'ouvre car le contact de d~brogation du vemilateur ne peurra fonctionner et clgager le boltler du radlateur de la chaleur ainsi emmagasimie. ENTRETIEN ATTENTION: S'assurer que I'alimentation de courant eat debrancl~e avant de commencer I'entretien de I'appareil ou de le ckbmonter. Si I'interrupteur de ralimentation West pas visible, v~rrouillez-le en pesition 'OUVERT" et ~btiquettez-le afin d'empechar qua I'on mette le couram. ENTRETIEN ELECTRIQUE Inspectez la filede du panneau de contrOle une fois par an afin de vous assurer qua I'isolant est intact et qua tdutes les connections sont solides. Inspectez tousles contacts du relais et du radiateur. Si les contin, apparais- sent trbs piqu~bs ou brOld~s, remplacez le relais/contacteur. Pour une protection correcte du circuit dumnt le fonc- tionnement I'intensit~ correcte du fusible doit §tre choisie. La liste de mat~bdel indique I'intensit~b des fusibles pour tousles appareils. 8 NETTOYAGE NettoyeZ ie boltier de I'appareil, le ventilateur et le moteur une fois par an. Un moteur encrasmb aura tendance chauffer et ~ventuellement ~ se d~t&dorer. Lea endroits rouilkbs du boltier doivent &tre n~bttoy~s et repeints. LUBRIFICATION Les appareils jusqu'b 20 KW ont des moteurs de ven- tilateurs qui sont lubrifi~s en permanence de sorte qu'ils ont besoin d'un nettoyage occasional seulement. Les ap- parells au-dessus de 20 KW ont des moteurs de ven- tilateurs lubrifibs pour un fonctionnement continu de 5 ans ou peur un fonctionnement intermitrant de 10 ans. Quand il est nebc~ssaire, enlevez le bouchon d'accbs de I'huit;""~ A I'arribre du radiateur, prbs de la grille d'entr~be, ouvre.. le capuchon d'huile, remplissez avec de I'huile moteur ~blectrique S.A.E. No. 10, puis replacez les capuchons et le bouchon. SHEMA DE FILERIE & TABLEAU SHEMA CODE WD5101 FIF-GIG-HFIB WD5104 GIG WD5106 F2F-HF2B WD5113 F2F WD5114 HF2B WD5138 P3P P3P WD5121 F3F WD5122 HF3B W05125 F3F F3F WD5126 HF3B HF3B WD5139 P3P WD5140 P3P WD5141 P3P WD5142 U3H WD5143 U3H CALIBRE 5103N 5107CAI L 5103N 5107CALL 5107CAI L 5103CAIN 5110CAIN 5115CALL 5115CALL 5125CAI L 5150CALL 5125CAI L 5150CALL 5125CAIN 5140CAIN 5150CAIN 5105CA4N 5115CA4N 5125CA4N 5150CA4N 5105N 5110CAI L 5105N 5110CALL 5110CALL 5105CAIN 5115CAIN ' 5120CALL 5130CALL 5130CALL 5130CAI N 5107CA4N 5120CA4N 5130CA4N 5107CAI N 5120CAIN 5140CALL 5140CALL 5110CA4N 5140CA4N DESSIN DES PIECES 10 LISTE DE MATERIEL DES NUMEROS DE CATALOGUE REVISED 3/91 * HEATER ELEMENT MODI~;I. ES MOTEl JR MONTI[ F1 F5103N 56562-012 60715-001 F2F5103N 56562-012 60715-011 HFIB5103N 56562-017 60715.002 HF285103N 56562-017 60715-012 G1G5103N 56562-016 60715.4)07 P3P5103CA1N 56562-018 60715008 FIF5105N 56562-012 607154)03 F2F5105N 56562-012 60715.004 HF1 B5105N 56562-017 607154)05 HF2B5105N 56562-017 60715006 GIG5105N 56562-016 60715-009 P3P5105CAIN 56562-018 60715.010 F2F5107CA1L 56823-011 56954-004 HF285107CA1L 56823-012 569~4 006 G1G5107CA1L 568244)02 56954-001 P3P5107CA1N 58824-011 5695 ~ ,002 F2F5110CAIL 56823-011 56954003 HF2B5110CA1L 56823-012 569544)04 GIG5110CAIL 568244)02 56954.007 P3P51 10CA1N 56824-011 56~;~ 008 F3F5115CA1L 56825-001 56C54 ,(X)9 HF3B5115CAIL 56825-002 56954-010 P3P5115CAIN 56825.003 56954-011 -"""' HF3B5120CAIL 56825-002 56954-012 P3P5120CAIN 56825-003 56954-013 DEROGATION BLOC DIS REINCLENCH. DU lOllIll AUTOMATIQUE VENTILATEUR TRANSF. CONTACTEUR D'AUII. 57640-006 568114)01 568154)01 57640-006 56811-001 56815.001 57640-006 56811-001 568154)01 57640-006 56811-001 56815001 57640-006 56811-001 568154)01 57640-006 568114)01 60719-006 50378-016 56815-001 57640-006 568114)01 568154)01 576404)06 568114)01 568154)01 576404)06 56811-001 56815-001 57640-006 56811-001 56815-001 576404)06 568114)01 56e15-001 576404)06 568114)01 60719-006 50378-016 56815-001 576404)03 568114)01 60719.001 503784)22 56816-001 57640-003 568114)01 607194)01 50378-013 56816.001 57640.(X)3 568114)01 60719-006 503784)16 568154X)1 57640-003 56811.001 60719.4)01 50378.031 56816.001 57640-003 56811-001 60719-001 50378.0~1 56816.001 57640-003 568114)01 60719.005 50378-022 568164)01 576404)03 56811.001 60719-006 50378.O16 56815.4)01 57640-004 56811-001 607194X)1 503784)31 56816-001 57640.004 56811-001 60719.001 50378-022 568164)01 57640-004 568114)01 60719.006 50378-016 56815..001 57640.4)04 568114)03 60719-006 50378-016 56815..001 HIA11R F3F5125CAIL 56943001 56954017 57640,(X)5 .HF385125CAIL 569434)02 56954018 576404)05 P3P5125CAIN 56~'~'~O01 56954-019 576404)05 F3F5130CA1L 56943001 56954020 57640006 HP3BS130CA1L 569434)02 56954-021 57640-005 P3PS130CA1N 56944-001 56954.0'22 57644).4)05 F3F5140CA1L 569454)01 56954-023 57640,005 HF385140CAIL 56945-002 56954-0;4 57640-006 568114)02 607194)09 50836-012 41280.002 50378-025 570974)01 571124)01 568114)02 60719-009 50836-012 41280-007 50378-025 570r/'.001 571124)01 568114)02 60719.012 -- -- 50378-016 570ge.001 570g0-001 58811.002 607194)09 50836003 41280.00e 50~78.025 570974)01 57112-001 56811-002 60719.009 50836-012 412804)02 503784)25 57097.001 57112.001 568114)02 60719-012 -- -- 50378-016 57098-001 57090,001 568114)02 60719-009 ~ 412804)04 50378-025 b'7097-001 571124)01 568114)02 60719-009 508364)03 41280-003 50378.4)25 b"/097-001 57112-001 P3P5140CAIN 56946-001 56954-025 57640.005 56~11-002 607194)12 -- -- 50378-016 570964)01 570g0-001 F3F5150CAIL 56945-001 56954-026 576404)05 56811.003 60719-009 508364:X~ 412804)05 50378-4)34 57097-001 57112-001 HF3B5150CA1L 56945-002 569544)27 57640-005 56811.003 60719.009 50836-003 412804)04 50378-026 570974)01 571124)01 P3PS150CAIN 56946-001 56e54-026 57640.005 56811-003 60719.O12 57110-001 57111.4)06 50378.016 57097-001 5701).001 NL.= · ·, PLAQUe · l,- CONNECT. CONDENEAT. KW DE VEN DE BORNES DE MALT DU MOTEUR VOLET 3.3-5 56806-001 56809-001 1458 -- (5) 56986-001 7.5-10 51554-002 56809-001 1456 -- (7') 56986-003 15-20 56813-001 56809-001 1456 -- (7) 56986-003 25-30 57114-001 56809-001 3981 57100-001 (9) 569874)01 40-50 57115-001 56809-001 3981 57100-001 (9) 56987-001 LISTE DE MATERIEL DES NUMEROS DE CATALOGUE MOTEUR ELEMENT MONTE REENCLENCH. AUTOMATIQUE DEROGATION DU VENTILATEUR TRANSF. CONTACTEUR BLOC DES BORNES D'AUM. AILETTE DE VENTIL PI, AQUETTE DE BORNES CONNECT. DE MALT VOLET U3H5105CA4N 565624) 17 56954-029 57640-003 568114)01 57641,003(100VA) 50378-018 515544)02 56809-001 1458 U3H5107CA4N 56823-012 56954-030 57640.003 56~114)01 57641-001(150VA) 50378-018 568154)01 515544)02 56809-001 1458 U3H5110CA4N 56823-012 56954-031 57640-003 56811-001 57641-001 50378-018 515544)02 56809-001 1458 U3H5115CA4N 568254302 56954-032 57640.004 56811-001 57641-002(300VA) 50378-018 568154)01 56813-001 56809-001 1458 U3H5120CA4N 56825-00; 56954-035 57640-004 56811-003 50378-018 56815-001 568134)01 56809001 1458 MOTEUR ELEMENT MONTE REENCLENCH. AUTOMATIQUE DEROGATION DU VENTILATEUR TRANSF, CONTACTEUR BLOC DES BORNES D'AUM. AILETTE DE VENTIL PLAQUETrE DE BORNES CONNECT. DE MALT VOLET BLOCK DE FUSIBLE FUSIBLE (2) INTERRUPT. DE VITESSE DU VENTIL CONDENSAT. DU MOTEUR U3H5125CA4N 569434)02 569544)33 576404)05 56811-002 57641-001 57098-001 57114-001 568094)01 3981 5ees4~9) 57643-001 57644.001(2) 571124)01 571004)01 U3H5130CA4N 56943-002 576404)05 56811-4)02 57641-001 57098-001 57114,001 588094)01 3981 576434)01 57~;;O01(2) 571124)01 57100-001 U3H5140CA4N 56N5-002 569~,~ 036 576404)05 568114)02 576414)04(350VA) 57098.001 57115.001 56809-001 3gel 56986-0O4(9) 576434)01 576444)01(2) 57112-001 57100-001 U3H5150CA4N 56N5-002 569544)37 576404X)5 568114)03 57841.004 57098,001 57115-001 568094)01 3981 5698e 00~(9) 57843.001 57644-001(2) 571124)01 571004)01 GAFIANTIE LIMITEE DE rr~ TpI Corporation Dumm Is IMeme cle I~ Wantle. Markel Pmckac~ Co. ramplacers ou rlIMmm &eonc:Metouteeml~lmeou;roduaremwrm, lx~tpay~ilefrNx~luede Leepfo~bremunmdolvemNmeneNIdmeireuememmMwkellNMum C~. newerropes,,/-r~se~le desdiglWencmaruedurmmletrwmxm. L.enlue vou~rmoumezlel~lmeefNeenoueee~oirlenumlrodulxoclueellanalurem {MicadleequevousevefencontrtCeltegBfamien'obligelaBMekeIPf,~k____,,:~._ moral, appateil ou pilce. La comlagnie n'aeume aucune rl~l~)t;:ldl iesfraisls ~n~-'e. idlmentmdel'appmmi& lelrNoumMquiencNmoulem. Deelreieeemm Ixlmee~Mt~urdeerlly .r'-~cMIxoclu~lNmalx4m|'ea~rmionclelalXemcle derdOarerlepmch~louegrentie. LllrltlDorkl bi'ill meximumdeM Pmdu~ Co. n'exd~leramenma~una lBIxtx devemBdu lRxNitdonnlpout Sir_ ~_%'~ Cetegaraee~eueclonnemclrNeMgaexRa4~Nemvouepou~zem. d'aulresdroi~qui peuventveie~d'Mll enNeI. Afin dellv~'le nOm de volre centre r4eaions Mekel le I~us Ixoche, ievez S.V.P. & Mekel ~ EnBuptllmem&lagaranlleimeee,, _~tionnleci-deeuscouwantleelxoduee qui sont garantis 8u Ixemie consommeur li lartir de la dale d'ohgine de I'achat, pendant les pckiodes de temia indiqudes ci-deslous: Bintents clans ~s s4mes 5100 r~ TPI Corporation P.O. Box 4973 Johnson City, TN 37602 (423)477-4 131 (423)477-0064 (USA~' '~NSON CITY, TN 376024973 Printed in U.S~. I' "t 1T ....