Loading...
Duke Freeport-LR160906LETTER OF TRANSMITTAL TO: ATTN: JOB NO.: DATE: RE: PERMIT #: LOCATION: We are enclosing: Attached Materials Engineering Division Concrete Reports:As Requested CC: By: For Your Use 09/06/2016 Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 006710A Mr. Sean Jeanes, P.E. LEED AP Duke Realty South/W est Region 14241 North Dallas Parkway, Suite 1000 Dallas, TX 75254 Duke Realty - Todd Henry Duke Realty - Glen Stevenson Mark R. Zortman, P.E. Principal Engineer Pacheco Koch Consulting Engineers - Clayton J. Strolle, City of Coppell - Matt Mabry Weir Bros., Inc. - Mike W eir Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Timothy Tarbutton Project Manager 51, 52, 53, 54, 50, 55, 69, 70, 71, 73, 72 CONCRETE, GROUT, AND MORTAR TESTS3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] X X X X Dallas County SEP 2 2016 ECS Texas, LLP Texas Registered Engineering Firm # F-8461 This report (and any included attachments) shall not be reproduced, except in full, without the prior written approval of ECS. Texas Registered Engineering Firm # F-8461 4000 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 51 07/07/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:A 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Tilt W all Panels at Grindlines from A-E/1.3, A/1.3-5, and A-C/5. LMC 7003 63103364 1600 4000 psi 06:36AM 10 Gals.Added W ater: 85º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Milton E. Perez 06:59AM 5.00 in. 0.50 % (P) Tested by: 87º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 22402812013749107/11/2016 4 Lab 4.00 12.56 3 TT02U 35204444813749207/14/2016 7 Lab 4.01 12.62 3 TT02U 32504101613749307/13/2016 6 Lab 4.01 12.62 3 TT02U 37404717613749407/16/2016 9 Lab 4.01 12.62 3 TT02U 48706147213749508/04/2016 28 Lab 4.01 12.62 3 TT02U 48106072813749608/04/2016 28 Lab 4.01 12.62 2 TT02U 47606006413749708/04/2016 28 Lab 4.01 12.62 2 TT02U 49406239813749809/01/2016 56 Lab 4.01 12.62 3 TT02U FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/06/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 4000 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 52 07/07/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:B 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Tilt W all Panels at Grindlines from A-E/1.3, A/1.3-5, and A-C/5. LMC 0168 63103374 1600 4000 psi 07:32AM 0Added W ater: 88º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Milton E. Perez 07:56AM 5.50 in. 1.40 % (P) Tested by: 88º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 24603088013749907/11/2016 4 Lab 4.00 12.56 3 TT02U 34704376813750007/14/2016 7 Lab 4.01 12.62 3 TT02U 32104051213750107/13/2016 6 Lab 4.01 12.62 3 TT02U 36404602413750207/16/2016 9 Lab 4.01 12.62 3 TT02U 46805916813750308/04/2016 28 Lab 4.01 12.62 3 TT02U 46705893613750408/04/2016 28 Lab 4.01 12.62 2 TT02U 45505741813750508/04/2016 28 Lab 4.01 12.62 2 TT02U 47305940913750609/01/2016 56 Lab 4.00 12.56 3 TT02U FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/06/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 4000 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 53 07/07/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:C 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Tilt W all Panels at Grindlines from A-E/1.3, A/1.3-5, and A-C/5. LMC 0000 00000000 1600 4000 psi 07:44AM 0Added W ater: 88º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Milton E. Perez 08:25AM 5.00 in. 1.70 % (P) Tested by: 89º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 23802995213750707/11/2016 4 Lab 4.00 12.56 3 TT02U 33904260013750807/14/2016 7 Lab 4.00 12.56 3 TT02U 30903906413750907/13/2016 6 Lab 4.01 12.62 3 TT02U 36104538613751007/16/2016 9 Lab 4.00 12.56 3 TT02U 46905892813751108/04/2016 28 Lab 4.00 12.56 3 TT02U 47906018413751208/04/2016 28 Lab 4.00 12.56 2 TT02U 47405984813751308/04/2016 28 Lab 4.01 12.62 3 TT02U 48106046413751409/01/2016 56 Lab 4.00 12.56 3 TT02U FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/06/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 4000 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 54 07/07/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:D 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Tilt W all Panels at Grindlines from A-E/1.3, A/1.3-5, and A-C/5. LMC 0001 62999089 1600 4000 psi 10:46AM 0Added W ater: 88º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Milton E. Perez 11:22AM 4.50 in. 3.20 % (P) Tested by: 96º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 24603109613751507/11/2016 4 Lab 4.01 12.62 3 TT02U 34804375213751607/14/2016 7 Lab 4.00 12.56 3 TT02U 32004024013751707/13/2016 6 Lab 4.00 12.56 3 TT02U 36804644813751807/16/2016 9 Lab 4.01 12.62 3 TT02U 47506004013751908/04/2016 28 Lab 4.01 12.62 3 TT02U 54606895313752008/04/2016 28 Lab 4.01 12.62 3 TT02U 48406108013752108/04/2016 28 Lab 4.01 12.62 2 TT02U 48906149413752209/01/2016 56 Lab 4.00 12.56 2 TT02U FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/06/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 4000 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 50 07/07/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:E 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Pavement on Private Drive by Bethel Road LMC 1416 63103416 1701 4000 psi 01:24PM 0Added W ater: 88º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Milton E. Perez 02:17PM 5.75 in. 3.40 % (P) Tested by: 90º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 32504110413748607/14/2016 7 Lab 4.01 12.62 3 TT02U 45005653613748708/04/2016 28 Lab 4.00 12.56 3 TT02U 44105573613748808/04/2016 28 Lab 4.01 12.62 3 TT02U 43305472013748908/04/2016 28 Lab 4.01 12.62 3 TT02U 44105564813749009/01/2016 56 Lab 4.01 12.62 3 TT02U FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/06/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 3000 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 55 07/08/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:A 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Footings at Gridlines L/1-4.7 LMC 0000 00000000 5150 3000 psi 01:15PM 0Added W ater: 93º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Milton E. Perez 01:51PM 5.25 in. 1.10 % (P) Tested by: 91º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 22202793613767907/15/2016 7 Lab 4.00 12.56 3 TT02U 29903760013768008/05/2016 28 Lab 4.00 12.56 3 TT02U 29403696013768108/05/2016 28 Lab 4.00 12.56 3 TT02U 28603593613768208/05/2016 28 Lab 4.00 12.56 3 TT02U 31103911213768309/02/2016 56 Lab 4.00 12.56 3 TT02U FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/06/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 3600 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 69 08/04/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:A 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Pavement Pour 5 LMC 7017 64412538 1701 3600 psi 04:55AM 0Added W ater: 90º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Zerubabel A. Gudeta 05:40AM 4.50 in. 3.00 % (P) Tested by: 87º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 27503452013965508/11/2016 7 Lab 4.00 12.56 3 TT02U 38504866113965609/01/2016 28 Lab 4.01 12.62 3 TT02U 37004678013965709/01/2016 28 Lab 4.01 12.62 3 TT02U 37404724813965809/01/2016 28 Lab 4.01 12.62 3 TT02U 139659 09/29/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing Box Ice Other Print Date:09/06/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 3600 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 70 08/04/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:B 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Pavement Pour 5 LMC 0314 63000700 1701 3600 psi 06:19AM 0Added W ater: 90º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Zerubabel A. Gudeta 07:17AM 5.00 in. 3.20 % (P) Tested by: 91º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 25703245613966008/11/2016 7 Lab 4.01 12.62 3 TT02U 37004671213966109/01/2016 28 Lab 4.01 12.62 3 TT02U 37604745113966209/01/2016 28 Lab 4.01 12.62 3 TT02U 35804498013966309/01/2016 28 Lab 4.00 12.56 3 TT02U 139664 09/29/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing Box Ice Other Print Date:09/06/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 3600 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 71 08/04/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:C 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Pavement Pour 5 LMC 0257 63104528 1701 3600 psi 07:30AM 0Added W ater: 90º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Zerubabel A. Gudeta 08:53AM 4.40 in. 3.00 % (P) Tested by: 90º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 25803260813966508/11/2016 7 Lab 4.01 12.62 3 TT02U 38304841913966609/01/2016 28 Lab 4.01 12.62 3 TT02U 36704610513966709/01/2016 28 Lab 4.00 12.56 3 TT02U 36104555913966809/01/2016 28 Lab 4.01 12.62 3 TT02U 139669 09/29/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing Box Ice Other Print Date:09/06/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 3600 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 73 08/04/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:D 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Pavement Pour 5 LMC 0004 63000722 1701 3600 psi 08:27AM 0Added W ater: 90º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Zerubabel A. Gudeta 09:54AM 4.90 in. 3.00 % (P) Tested by: 93º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 24803128013967708/11/2016 7 Lab 4.01 12.62 3 TT02U 37204699513967809/01/2016 28 Lab 4.01 12.62 3 TT02U 35604472513967909/01/2016 28 Lab 4.00 12.56 3 TT02U 37004668213968009/01/2016 28 Lab 4.01 12.62 3 TT02U 139681 09/29/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/06/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 3600 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 72 08/04/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:Z 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Decorative concrete at the South approach LMC 63104534 1701 3600 psi 08:19AM 0Added W ater: 90º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Zerubabel A. Gudeta 09:13AM 5.00 in. 3.50 % (P) Tested by: 90º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 33204198413967008/11/2016 7 Lab 4.01 12.62 3 TT02U 30803894613967108/08/2016 4 Lab 4.01 12.62 3 TT02U 34604345613967208/11/2016 7 Lab 4.00 12.56 3 TT02U 39004929713967309/01/2016 28 Lab 4.01 12.62 3 TT02U 41205174713967409/01/2016 28 Lab 4.00 12.56 3 TT02U 42605383213967509/01/2016 28 Lab 4.01 12.62 3 TT02U 139676 09/29/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing Box Ice Other Print Date:09/06/2016 TT02 BR01