Loading...
Duke Freeport-LR160906 (2)LETTER OF TRANSMITTAL TO: ATTN: JOB NO.: DATE: RE: PERMIT #: LOCATION: We are enclosing: Attached Materials Engineering Division Concrete Reports:As Requested CC: By: For Your Use 09/06/2016 Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 006710A Mr. Sean Jeanes, P.E. LEED AP Duke Realty South/W est Region 14241 North Dallas Parkway, Suite 1000 Dallas, TX 75254 Duke Realty - Todd Henry Duke Realty - Glen Stevenson Mark R. Zortman, P.E. Principal Engineer Pacheco Koch Consulting Engineers - Clayton J. Strolle, City of Coppell - Matt Mabry Weir Bros., Inc. - Mike W eir Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Timothy Tarbutton Project Manager 84, 85, 86, 87 CONCRETE, GROUT, AND MORTAR TESTS3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] X X X X Dallas County SEP 6 2016 POSSIBLE LOW 28-DAY TEST RESULTS REPORTS 85 ECS Texas, LLP Texas Registered Engineering Firm # F-8461 This report (and any included attachments) shall not be reproduced, except in full, without the prior written approval of ECS. Texas Registered Engineering Firm # F-8461 3600 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 84 08/27/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:A 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Pavement LMC 5015 76830375 5409 3600 psi 08:32AM 0Added W ater: 85º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Edward Sesay 09:06AM 5.00 in. 3.20 % (P) Tested by: 80º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 31403969514111009/03/2016 7 Lab 4.01 12.62 2 TT02U 141111 09/24/2016 28 Lab 141112 09/24/2016 28 Lab 141113 10/22/2016 56 Lab 141114 09/24/2016 28 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/06/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 3600 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 85 08/27/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:B 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Sidewalk LMC 3035 76830385 5177 3000 psi 11:46AM 0Added W ater: 95º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Edward Sesay 12:25PM 5.00 in. 3.10 % (P) Tested by: 85º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 25603235614111509/03/2016 7 Lab 4.01 12.62 3 TT02U 141116 09/24/2016 28 Lab 141117 09/24/2016 28 Lab 141118 10/22/2016 56 Lab 141119 09/24/2016 28 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other POSSIBLE LOW 28-DAY TEST RESULTS Print Date:09/06/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 3500 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 86 08/29/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:A 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Pour Strip and removed Slab on Grade Panels. LMC 7003 76830388 1418 3500 psi 06:34AM 15 Gals.Added W ater:Time Added:07:29AM 86º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Darius Abayisenga 07:31AM 4.75 in. 1.10 % (P) Tested by: 88º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 33504227314120609/05/2016 7 Lab 4.01 12.62 3 TT02U 141207 09/26/2016 28 Lab 141208 09/26/2016 28 Lab 141209 09/26/2016 28 Lab 141210 10/24/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/06/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 3500 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 87 08/29/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:B 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Pour Strip and removed Slab on Grade Panels. LMC 5015 76830426 1418 3500 psi 01:40PM 20 Gals.Added W ater:Time Added:02:20PM 95º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Darius Abayisenga 02:49PM 5.00 in. 0.90 % (P) Tested by: 92º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 32904150814121109/05/2016 7 Lab 4.01 12.62 3 TT02U 141212 09/26/2016 28 Lab 141213 09/26/2016 28 Lab 141214 09/26/2016 28 Lab 141215 10/24/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/06/2016 TT02 BR01