Sonic-LR160901Alpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 Tested For: MIRA ENTERPRISES ATTN: MIKE BATTEAS 9500 IH 20 EASTLAND, TX 76448 Fax Number: (254) 629-0978 Project Desc: SONIC RESTAURANT Date Issued: 09/01/2016 Our Report #: 161578-14 PM: TODD SMITH 201 NORTH DENTON TAP ROAD FIELD DA TA Placement Location: PAVING: WEST SIDE OF BUILDING Sample Location: N/A Date Placed: 8/2/2016 Concrete Supplier: N/A Time Placed: N/A Plant Number: N/A Cast By: CONTRACTOR D 1'IT' k e my Ic et No.. Result Concrete Temp (F): N/A Slump (ASTM C-143): N/A Air Content: N/A Ambient Temp (F): N/A Unit Weight: N/A e my Ic et No.. N/A Batch Time: N/A Mix ID: N/A Submitted By: CONTRACTOR Date Received: 8/3/2016 Cured Specification: ASTM C-31 Specified Strength: 3500 CYLINDER COMPRESSION TEST RESULTS Lab Cure Break Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 21 LAB 2 C-1231 8/9/2016 7 8 N/A 4 12.56 40210 3200 22 LAB 3 C-1231 8/30/2016 28 8 N/A 4 12.56 45245 3600 23 LAB 5 C-1231 8/30/2016 28 8 N/A 4 12.56 42100 3350 24 LAB 3 C-1231 8/30/2016 28 8 N/A 4 12.56 46611 3710 Average 28 -day Compressive Strength is compliant with project specifications 3550 Notes: All information other the test results was furnished by others and assumed to be correct. Ashoke Saha picked up the cylinders. CC: Respectfully Submitted 8y: of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar ' = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245704 Alpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 Tested For: MIRA ENTERPRISES ATTN: MIKE BATTEAS 9500 IH 20 EASTLAND, TX 76448 Fax Number: (254) 629-0978 Project Desc: SONIC RESTAURANT 201 NORTH DENTON TAP ROAD FIELD DATA Placement Location: PAVING: FIRE LANE, SOUTH SIDE OF BUILDING Sample Location: 60'S & 25'E FROM SE CORNER OF BUILDING Date Placed: 8/23/2016 Time Placed: 7:33 AM Cast By: ALPHA Date Received: Result Concrete Temp (F): 86 Slump (ASTM C-143): 4.5 Air Content: 4.6 (ASTM C-231) Ambient Temp (F): 78 Unit Weight: N/A CC: Date Issued: 08/30/2016 Our Report #: 161578-20 PM: TODD SMITH Concrete Supplier: BIG D Plant Number: 131 Delivery Ticket No.: 68417 Batch Time: 6:14:00 AM Mix ID: N/A Submitted By: Garcia, Cristian Date Received: 8/24/2016 Cured Specification: ASTM C-31 Specified Strength: 3600 CYLINDER COMPRESSION TF.RT PF.gl11 T -C Lab No.: Cure Type: Break Cap Type: Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq. In. Max Load: PSI: 37 LAB 3 C-1231 8/30/2016 7 8 N/A 4 12.56 43620 3470 38 LAB C-1231 9/20/2016 28 8 N/A 4 12.56 0 39 LAB C-1231 9/20/2016 28 8 N/A 4 12.56 0 40 LAB C-1231 9/20/2016 28 8 N/A 4 12.56 0 Respectfully Submitted By: of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar " = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C136. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing'' Environmental Engineering * Consulting 247619 Alpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 Tested For: MIRA ENTERPRISES ATTN: MIKE BATTEAS 9500 IH 20 EASTLAND, TX 76448 Fax Number: (254) 629-0978 Project Desc: SONIC RESTAURANT 201 NORTH DENTON TAP ROAD Date Issued: 08/30/2016 Our Report #: 161578-12 PM: TODD SMITH FIELD DATA Placement Location: PAVING: NORTH & WEST SIDE Sample Location: 20'E & 40'N FROM SW CORNER OF PROJECT Date Placed: 8/1/2016 Concrete Supplier: BURNCO Time Placed: 11:45 AM Plant Number: 506 Cast By: ALPHA Delivery Ticket No.: 50418427 CC: Respectfully Submitted By: —2 of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245505 Result Batch Time: 10:40:00 AM Concrete Temp (F): 85 Mix ID: 35U500BG Slump (ASTM C-143): 5.0 Submitted By: Saha, Ashoke Air Content: 4.8 Date Received: (ASTM C-231) 8/2/2016 Ambient Temp (F): 75 Cured Specification: ASTM C-31 Unit Weight: N/A Specified Strength: 3500 CC: Respectfully Submitted By: —2 of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245505 CYLINDER COMPRESSION TEST RESULTS Lab No.: Cure Type: Break T pe: Cap Date Age Avg. Spec: Tested: (Days): Length Avg. Width Avg Depth/ Diameter Area: Sy. In. Max Load: PSI: 13 LAB 2 C-1231 8/8/2016 7 8 N/A 4 12.56 29820 2370 14 LAB 2 C-1231 8/29/2016 28 8 N/A 4 12.56 43390 3450 15 LAB 2 C-1231 8/29/2016 28 8 N/A 4 12.56 44847 3570 16 LAB 2 C-1231 8/29/2016 28 8 N/A 4 12.56 43900 3500 Average 28 -day Compressive Strength is compliant with project specifications 3510 CC: Respectfully Submitted By: —2 of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245505 Alpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 Tested For: MIRA ENTERPRISES ATTN: MIKE BATTEAS 9500 IH 20 EASTLAND, TX 76448 Fax Number: (254) 629-0978 Project Desc: SONIC RESTAURANT 201 NORTH DENTON TAP ROAD Date Issued: 08/25/2016 Our Report #: 161578-8 PM: TODD SMITH FIELD DATA Placement Location: SIDEWALK: NORTH & SOUTH SIDE ALONG BUILDING Sample Location: 20'W & 1'N FROM NE CORNER OF BUILDING Date Placed: 7/28/2016 Concrete Supplier: BURNCO Time Placed: 1:00 PM Plant Number: 506 Cast By: ALPHA Delivery Ticket No.: 50411763 CC: Respectfully Submitted B11--7 -y:. of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245083 Result Batch Time: 12:08:00 PM Concrete Temp (F): 83 Mix ID: 35U500BG Slump (ASTM C-143); 4.5 Submitted By: Saha, Ashoke Air Content: 5.0 (ASTM C-231) Date Received: 7/29/2016 Ambient Temp (F): 78 Cured Specification: ASTM C-31 Unit Weight: N/A Specified Strength: 3500 CYLINDER COMPRESSION TEST RESULTS Lab Cure Break Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Type: Spec: Tested: (Days); Length Width Diameter Sq. in. Load: PSI: 9 LAB 5 C-1231 8/4/2016 7 8 N/A 4 12.56 29840 2380 10 LAB 2 C-1231 8/25/2016 28 8 N/A 4 12.56 46123 3670 11 LAB 2 C-1231 8/25/2016 28 8 N/A 4 12.56 45979 3660 12 LAB 2 C-1231 8/25/2016 28 8 N/A 4 12.56 44610 3550 Average 28 -day Compressive Strength is compliant with project specifications 36301 CC: Respectfully Submitted B11--7 -y:. of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245083 Alpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 Tested For: MIRA ENTERPRISES ATTN: MIKE BATTEAS 9500 IH 20 EASTLAND, TX 76448 Fax Number: (254) 629-0978 Project Desc: SONIC RESTAURANT 201 NORTH DENTON TAP ROAD Date Issued: 08/24/2016 Our Report #: 161578-9 PM: TODD SMITH I FIELD DATA Placement Location: PAVING: NORTHEAST CORNER Sample Location: N/A Date Placed: 7/26/2016 Concrete Supplier: BURNCO Time Placed: N/A Plant Number: N/A Cast By: ALPHA Delivery Ticket No • 50411125 Batch Time: Result Concrete Temp (F): N/A Slump (ASTM C-143): N/A Air Content: N/A Ambient Temp (F): N/A Unit Weight: N/A Batch Time: N/A Mix ID: 35U500BG Submitted By: Saha, Ashoke Date Received: 7/27/2016 Cured Specification: ASTM C-31 Specified Strength: 3500 Notes: All information other than the test results was furnished by others and assumed to be correct. CC: Respectfully Submitted By; of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar ' = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245082 CYLINDER COMPRESSION TEST RESULTS Lab No.: Cure Type: Break Type: Cap Date Age Avg. Spec: Tested: (Days),. Length Avg. Width Avg Depth/ Diameter Area: Sq. In. Max Load: PSI: 5 LAB C-1231 8/2/2016 7 8 N/A 4 12.56 32500 2590 6 LAB 2 C-1231 8/23/2016 28 8 N/A 4 12.56 45830 3650 7 LAB 2 C-1231 8/23/2016 28 8 N/A 4 12.56 50431 4020 8 LAB 2 C-1231 8/23/2016 28 8 N/A 4 12.56 44730 3560 Average 28 -day Compressive Strength is compliant with project specifications 3740 Notes: All information other than the test results was furnished by others and assumed to be correct. CC: Respectfully Submitted By; of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar ' = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245082 Alpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 Tested For: MIRA ENTERPRISES ATTN: MIKE BATTEAS 9500 IH 20 EASTLAND, TX 76448 Fax Number: (254) 629-0978 Project Desc: SONIC RESTAURANT 201 NORTH DENTON TAP ROAD Date Issued: 08/19/2016 Our Report #: 161578-17 PM: TODD SMITH FIELD DATA Placement Location: NORTHEAST CORNER OF APPROACH Sample Location: N/A Date Placed: 8/12/2016 Concrete Supplier: N/A Time Placed: N/A Plant Number: B1 Cast By: CONTRACTOR Delivery Ticket No.: N/A Notes: All information other than the test results was furnished by others and assumed to be correct. Ashoke Saha picked up the cylinders. CC: Respectfully Submitted By: � r of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar " = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 247011 Result Batch Time: N/A Concrete Temp (F): N/A Mix ID: N/A Slump (ASTM C-143): N/A Submitted By: CONTRACTOR Air Content: N/A Date Received: 8/13/2016 Ambient Temp (F): N/A Cured Specification: ASTM C-31 Unit Weight: N/A Specified Strength: 4000 Notes: All information other than the test results was furnished by others and assumed to be correct. Ashoke Saha picked up the cylinders. CC: Respectfully Submitted By: � r of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar " = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 247011 CYLINDER COMPRESSION TEST RESULTS Lab No.: Cure Type: Break Cap Type: Spec: Date Tested: Age (Hays): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq. In. Max Load: PSI: 29 LAB 2 C-1231 8/19/2016 7 8 N/A 4 12.56 50096 3990 30 LAB C-1231 9/9/2016 28 8 N/A 4 12.56 0 31 LAB C-1231 9/9/2016 28 8 N/A 4 12.56 0 32 LAB C-1231 9/9/2016 28 8 N/A 4 12.56 0 - 1 Notes: All information other than the test results was furnished by others and assumed to be correct. Ashoke Saha picked up the cylinders. CC: Respectfully Submitted By: � r of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar " = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 247011 Alpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 Tested For: MIRA ENTERPRISES ATTN: MIKE BATTEAS 9500 IH 20 EASTLAND, TX 76448 Fax Number: (254) 629-0978 Project Desc: SONIC RESTAURANT 201 NORTH DENTON TAP ROAD FIELD DATA Placement Location: PAVING: EAST SIDE PATIO Sample Location: 25'E & 5'N FROM NE CORNER OF BUILDING Date Placed: 8/15/2016 Time Placed: 4:45 PM Cast By: ALPHA Date Received: Result Concrete Temp (F): 83 Slump (ASTM C-143): 4.5 Air Content: 4.0 (ASTM C-231) Ambient Temp (F): 65 Unit Weight: N/A Date Issued: 08/24/2016 Our Report #: 161578-19 PM: TODD SMITH Concrete Supplier: BIG D Plant Number: 131 Delivery Ticket No.: 68129 Batch Time: 3:50:00 PM Mix ID: N/A Submitted By: Saha, Ashoke Date Received: 8/16/2016 Cured Specification: ASTM C-31 Specified Strength: 3000 I CYLINDER COMPRESSION TEST RESULTS I Lab No.: Cure Type: Break Cap Type: Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq. In. Max Load: PSI: 33 LAB 2 C-1231 8/22/2016 7 12 N/A 6 28.27 34700 1230 34 LAB C-1231 9/12/2016 28 12 N/A 6 28.27 0 35 LAB C-1231 9/12/2016 28 12 N/A 6 28.27 0 36 LAB C-1231 9/12/2016 28 12 N/A 6 28.27 0 CC: Respectfully Submitted By: of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar ' = Specification out of spec Test Method: Unless noted, Concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering " Construction Materials Testing " Environmental Engineering , Consulting 247056 Alpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 Tested For: MIRA ENTERPRISES ATTN: MIKE BATTEAS 9500 IH 20 EASTLAND, TX 76448 Fax Number: (254) 629-0978 Project Desc: SONIC RESTAURANT 201 NORTH DENTON TAP ROAD Date Issued: 08/18/2016 Our Report #: 161578-6 PM: TODD SMITH FIELD DATA Placement Location: PIERS CAP OF CANOPY Sample Location: 7.5'N & 35'E FROM NE CORNER OF BUILDING Date Placed: 7/21/2016 Concrete Supplier: BURNCO Time Placed: 12:15 PM Plant Number: 506 Cast By: ALPHA Delivery Ticket No.: 50409809 CC: Respectfully Submitted By; of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar • = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 244031 Batch Time: 11:23:00 AM Result Concrete Temp (F): 79 Mix ID: 35U500BG Slump (ASTM C-143): 4.0 Submitted By: Saha, Ashoke Air Content: 5.0 (ASTM C-231) Date Received: 7/22/2016 Ambient Temp (F): 75 Cured Specification: ASTM C-31 Unit Weight: N/A Specified Strength: 3500 CYLINDER COMPRESSION TEST RESULTS Lab Cure Break Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 1 LAB 2 C-1231 7/28/2016 7 8 N/A 4 12.56 45501 3620 2 LAB 2 C-1231 8/18/2016 28 8 N/A 4 12.56 58700 4670 3 LAB 2 C-1231 8/18/2016 28 8 N/A 4 12.56 59630 4750 4 LAB 2 C-1231 8/18/2016 28 8 N/A 4 12.56 60023 4780 Average 28 -day Compressive Strength is compliant with project specifications 47301 CC: Respectfully Submitted By; of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar • = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 244031 ALPHA/ TESTING DAILY FIELD REPORT 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR: Mira Enterprises Eastland, Texas PROJECT: Sonic Restaurant Coppell, Texas TECHNICIAN: A. Saha WEATHER: Sunny DATE: 08/13/16 OUR REPORT NO.: 161578-16 TEMPERATURE RANGE: 70 to 80 degrees The Alpha technician traveled to the above referenced site to monitor ongoing work and perform field testing as requested, 4 of 4 x 8 molds were dropped for Slab on Grade at East Patio teptraeulh and reports ma for the exclusive use of the Respectfully Submitted, Todd Smith ALPHA TESTING, INC. on Ale in our office) and shall not be reproduced andlpr diatdbWed auepl vdth express test results must receive our written approval. Test results and reports apply onlyto the samples tested and/or observed, and are not indicative of the qualifies of apparently identical or s imilar specimens. name and ALPHA +NtTEST ING 2209 Dallas, Texas 75229in REPORT Suite 100 REPORT OF REINFORCING Geotechnical I Construction Materials I Environmental www.alphatesting.com STEEL OBSERVATION TBPE Firm No. 813 TESTED FOR: PROJECT: Mira Enterprises Eastland, Texas Sonic Restaurant Coppell, Texas DRAWINGS UTILIZED (SHEETS/DETAILS/DATE): S1.01 / Slab on Grade / 06-27-16 S2.01 / Foundation / 05-27-16 LOCATIONS/ITEMS OBSERVED: East Side Patio TEST METHOD: VISUAL OBSERVATION DATE: 08/13/16 OUR REPORT NO.: 161578-18 PROJECT DATA REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT PLACING DRAWINGS APPROVED X 13AR LENGTH AND SPACE X COLUMN TIE SPACING & TYPE N/A 13AR SIZE X PROPER BAR PLACEMENT X STIRRUP SPACING & TYPE N/A BAR GRADE X PROPERLY TIED X TENDON NO & SPACING N/A REBAR CLEAN X DOWEL BARS IN PLACE X 'WELDED SPLICES N/A FORM CLEAN X PROPER BAR SUPPORTS X IMECHANICAL SPLICES N/A NO OF BARS X PROPER COVER X ILAPPED SPLICES N/A DISCREPANCIES/COMMENTS: TECHNICIAN: A. Saha Respectfully Submitted, Todd Smith ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. I)LAlpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 Tested For: MIRA ENTERPRISES ATTN: MIKE BATTEAS 9500 IH 20 EASTLAND, TX 76448 Fax Number: (254) 629-0978 Project Desc: SONIC RESTAURANT 201 NORTH DENTON TAP ROAD FIELD DATA Placement Location: FIRE LANE: NORTH SIDE OF BUILDING Sample Location: 50'N & 20'W FROM NE CORNER OF BUILDING Date Placed: 8/4/2016 Time Placed: 7:30 AM Cast By: ALPHA Date Received: Result Concrete Temp (F): 81 Slump (ASTM C-143): 4.0 Air Content: 4.5 (ASTM C-231) Ambient Temp (F): 68 Unit Weight: N/A Date Issued: 08/11/2016 Our Report #: 161578-15 PM: TODD SMITH Concrete Supplier: BURNCO Plant Number: 506 Delivery Ticket No.: 50413292 Batch Time: 6:32:00 AM Mix ID: 35U500BG Submitted By: Saha, Ashoke Date Received: 8/5/2016 Cured Specification: ASTM C-31 Specified Strength: 3500 CC: Respectfully Submitted By: of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar ' = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering • Construction Materials Testing' Environmental Engineering • Consulting 246043 CYLINDER COMPRESSION TEST RESULTS Lab No.: Cure Type: Break Cap Type: Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq. In. Max Load: PSI: 25 LAB 2 C-1231 8/11/2016 7 8 N/A 4 12.56 29064 2310 26 LAB C-1231 9/1/2016 28 8 N/A 4 12.56 0 27 LAB C-1231 9/1/2016 28 8 N/A 4 12.56 0 28 LAB C-1231 9/1/2016 28 8 N/A 4 12.56 0 CC: Respectfully Submitted By: of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar ' = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering • Construction Materials Testing' Environmental Engineering • Consulting 246043 Alpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 Tested For: MIRA ENTERPRISES ATTN: MIKE BATTEAS 9500 IH 20 EASTLAND, TX 76448 Fax Number: (254) 629-0978 Project Desc: SONIC RESTAURANT 201 NORTH DENTON TAP ROAD Date Issued: 08/10/2016 Our Report #: 161578-13 PM: TODD SMITH I FIELD DATA Placement Location: FIRE LANE, WEST SIDE OF BUILDING Sample Location: 45'E & 20'N FROM SW CORNER OF BUILDING Date Placed: 8/3/2016 Concrete Supplier: BURNCO Time Placed: 9:30 AM Plant Number: 506 Cast By: ALPHA Delivery Ticket No.: 50413006 CC: Respectfully Submitted By: i'of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C136. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245703 Batch Time: 8:29:00 AM Result Cure Type: Break Cap Type: Spec: Concrete Temp (F): 84 Mix ID: 35U500BG Slump (ASTM C-143): 5.0 Submitted By: Saha, Ashoke Air Content: 4.0 (ASTM C-173) Date Received: 8/4/2016 Ambient Temp (F): 78 Cured Specification: ASTM C-31 Unit Weight: N/A Specified Strength: 3500 CC: Respectfully Submitted By: i'of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C136. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245703 CYLINDER COMPRESSION TEST RESULTS Lab No.: Cure Type: Break Cap Type: Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq. In. Max Load: PSI: 17 LAB 2 C-1231 8/10/2016 7 8 N/A 4 12.56 30490 2430 18 LAB C-1231 8/31/2016 28 8 N/A 4 12.56 0 19 LAB C-1231 8/31/2016 28 8 N/A 4 12.56 0 20 LAB C-1231 8/31/2016 28 8 N/A 4 12.56 0 CC: Respectfully Submitted By: i'of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C136. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245703 Alpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 Tested For: MIRA ENTERPRISES ATTN: MIKE BATTEAS 9500 IH 20 EASTLAND, TX 76448 Fax Number: (254) 629-0978 Project Desc: SONIC RESTAURANT 201 NORTH DENTON TAP ROAD Date Issued: 08/09/2016 Our Report #: 161578-14 PM: TODD SMITH FIELD DATA Placement Location: PAVING: WEST SIDE OF BUILDING Sample Location: N/A Date Placed: 8/2/2016 Concrete Supplier: N/A Time Placed: N/A Plant Number: N/A Cast By: CONTRACTOR Delivery Ticket No.: N/A Respectfully Submitted By. of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar ` = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C136. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245704 Batch Time: N/A Result Concrete Temp (F): N/A Mix ID: N/A Slump (ASTM C-143): N/A Submitted By: CONTRACTOR Air Content: N/A Date Received: 8/3/2016 Ambient Temp (F): N/A Cured Specification: ASTM C-31 Unit Weight: N/A Specified Strength: 3500 CYLINDER COMPRESSION TEST RESULTS Lab Cure Break Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 21 LAB 2 C-1231 8/9/2016 7 8 N/A 4 12.56 40210 3200 22 LAB C-1231 8/30/2016 28 8 N/A 4 12.56 0 23 LAB C-1231 8/30/2016 28 8 N/A 4 12.56 0 24 LAB C-1231 8/30/2016 28 8 N/A 4 12.56 0 Notes: All information other the test results was furnished by others and assumed to be correct. Ashoke Saha picked up the cylinders. CC: Respectfully Submitted By. of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar ` = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C136. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245704 ALPHA /TESTING llTexas 7522isconsin get, Suite 100 Dallas, REPORT OF REINFORCING Geotechnical I Construction Materials I Environmental STEEL OBSERVATION www.alphatesting.com TBPE Firm No. 813 TESTED FOR: PROJECT Mira Enterprises Eastland, Texas Sonic Restaurant Coppell, Texas DRAWINGS UTILIZED (SHEETS/DETAILS/DATE): C7.1 Section of Paving Details / 05-23-16 LOCATIONS/ITEMS OBSERVED: Canopy Area at North Side of Buildi Paving at NW Corner of Building TEST METHOD: VISUAL OBSERVATION DATE: 08/02/16 OUR REPORT NO.: 161578-10 PROJECT DATA REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT (PLACING DRAWINGS APPROVED X 13AR LENGTH AND SPACE X COLUMN TIE SPACING & TYPE N/A BAR SIZE X PROPER BAR PLACEMENT X STIRRUP SPACING & TYPE N/A BAR GRADE X PROPERLY TIED X 'TENDON NO. & SPACING N/A !REBAR CLEAN X DOWEL BARS IN PLACE X WELDED SPLICES N/A (FORM CLEAN X PROPER BAR SUPPORTS X MECHANICAL SPLICES N/A INO. OF BARS X .PROPER COVER X LAPPED SPLICES N/A DISCREPANCIES/COMMENTS: TECHNICIAN: A. Saha Respectfully Submitted, Todd Smith ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA The use of our name and test results must receive our written approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens Alpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 Tested For: MIRA ENTERPRISES ATTN: MIKE BATTEAS 9500 IH 20 EASTLAND, TX 76448 Fax Number: (254) 629-0978 Project Desc: SONIC RESTAURANT 201 NORTH DENTON TAP ROAD FIELD DATA Placement Location: SIDEWALK: NORTH & SOUTH SIDE ALONG BUILDING Sample Location: 20'W & 1'N FROM NE CORNER OF BUILDING Date Placed: 7/28/2016 Time Placed: 1:00 PM Cast By: ALPHA Date Received: Result Concrete Temp (F): 83 Slump (ASTM C-143); 4.5 Air Content: 5.0 (ASTM C-231) Ambient Temp (F): 78 Unit Weight: N/A Date Issued: 08/04/2016 Our Report #: 161578-8 PM: TODD SMITH Concrete Supplier: BURNCO Plant Number: 506 Delivery Ticket No.: 50411763 Batch Time: 12:08:00 PM Mix ID: 35U500BG Submitted By: Saha, Ashoke Date Received: 7/29/2016 Cured Specification: ASTM C-31 Specified Strength: 3500 I CYLINDER COMPRESSION TEST RESULTS Lab No.. Cure Type. Break Cap Type: Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq. In. Max Load: PSI: 9 LAB 5 C-1231 8/4/2016 7 8 N/A 4 12.56 29840 2380 10 LAB C-1231 8/25/2016 28 8 N/A 4 12.56 0 11 LAB C-1231 8/25/2016 28 8 N/A 4 12.56 0 12 LAB C-1231 8/25/2016 28 8 N/A 4 12.56 0 CC: Respectfully Submitted By: —�—�J of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar " = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245083 A LPH A /0'%TEST I N G REPORT OF FIELD 2209 Wisconsin Street, Suite 100 COMPACTION TESTS Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR: PROJECT: TEST DATA: Mira Enterprises Eastland, Texas Sonic Restaurant Coppell, Texas DATE: 07/14/16 OUR REPORT NO.: 161578-5 TECHNICIAN: A. Saha TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE h MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT* 5 07/14/16 FG 2 10.7 117.3 11.5 114 97 1-A 6 07/14/16 FG 2 10.7 117.3 11.0 1 115 98 1-A 7 07/14/16 FG 2 10.7 117.3 10.9 115 98 1-A TEST LOCATION: Parkina Lot 5 25' E and 25' N from NW Corner of Building 6 50' E and 25' N from NW Corner of Building 7 20'W and 25' N from NE Corner of Building 1 FILL *A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2 NATURAL SUBGRADE B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted. 4. CEMENT TREATED D. RETEST Todd Smith ALPHA TESTING, INC. Our lest results and reports are for the exclusive use of the Client (and their designated red pie nls on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA The use of our name and test results must receive our written approval Test results and reports apply only to the samples tested a ndlorobserved, and are not indicative of the qua lilies of apparently identical or similar specimens A L PH A #%tTESTING REPORT OF FIELD 2209 Wisconsin Street, Suite 100 COMPACTION TESTS Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR: PROJECT: TEST DATA: Mira Enterprises Eastland, Texas Sonic Restaurant Coppell, Texas DATE: 07/08/16 OUR REPORT NO.: 161578-4 TECHNICIAN: A. Saha TEST NO, DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT" 1 07/08/16 FG 3 8.7 119.8 12.2 116 97 1-A 2 07/08/16 FG 3 8.7 119.8 11.8 117 98 1-A 3 07/08/16 FG 3 8.7 119.8 12.4 115 96 1-A 4 07/08/16 FG 3 8.7 119.8 12.0 116 97 1-A TEST LOCATION: Buildina Pad 1 25' E and 25' S from NW Corner of Building Pad 2 25' E and 25' S from SW Corner of Building Pad 3 125'W and 25'S from NE Corner of Building Pad 4 25'W and 25'S from SE Corner of Building Pad 1 FILL *A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Todd Smith ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA The use of our name and test results must receive our written approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualifies of apparently identical or similar specimens ALPHA /TESTING 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR: Mira Enterprises Eastland, Texas PROJECT: Sonic Restaurant Coppell, Texas TECHNICIAN: Jeff Utley 135 130 125 110 105 100 Ill - 0% OUR REPORT NO.: 161578-3 DATE: 07/01/16 MATERIAL DESCRIPTION: DARK BROWN CLAYEY SAND WITH CRUSHED CONCRETE CLASSIFICATION: SC SAMPLE LOCATION: 20'S x 50'W FROM NE CORNER (COPPELL, TX) TEST METHOD: ASTM D698 -B SOIL ID NUMBER: 3 MAXIMUM DRY UNIT WEIGHT: 1198 PCF OPTIMUM MOISTURE CONTENT: 8.7 % LIQUID LIMIT: 25 PLASTIC LIMIT: 9 PLASTICITY INDEX: 16 % FINER THAN NO. 200 SIEVE: 33% MOISTURE DENSITY RELATIONSHIP 5% 10% 15% 20% 25% 30% MOISTURE CONTENT Res ectfully Submitted, Todd Smith ALPHA TESTING, INC. + tasT reauna am ropana are 10(Tri? excluelve use of I" rIA W [and lhetr dasrgnGietl recipients on rile Irl our office) and shall not be reproduced andfor dIStributad except wilt, express approval of Alpha. The use of our name and test results must receive our written approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently Identical or similar specimens 35% �ALPHA #NJE ST I N r. 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 ED FOR: Mira Enterprises Eastland, Texas PROJECT: Sonic Restaurant Coppell, Texas TECHNICIAN: Jeff Utlev iRII 12,' —71 7 v N 120 H 2 W ir t: 115 Z } is[@] 105 100 00 OUR REPORT NO.: 161578-2 DATE: 07/01/16 MATERIAL DESCRIPTION: DARK BROWN CLAYEY SAND SOME CRUSHED CONCRETE CLASSIFICATION: SC SAMPLE LOCATION: 100'N x 20'W FROM SE CORNER (COPPELL, TX) TEST METHOD: ASTM D698 -B SOIL ID NUMBER: 2 MAXIMUM DRY UNIT WEIGHT: 117.3 PCF OPTIMUM MOISTURE CONTENT: 10.7 % LIQUID LIMIT: 31 PLASTIC LIMIT: 12 PLASTICITY INDEX: 19 % FINER THAN NO. 200 SIEVE: 82% MOISTURE DENSITY RELATIONSHIP b /0 10% 15% 20% 25% 30% 35% MOISTURE CONTENT Res ectfully Submitted, Todd Smith ALPHA TESTING, INC. Our teal rasul[Y anA neons are to( the exCluSpve use or trio rr,*M (and [hair de$Nnaled reeiplonts on fife in Our ofhcoj and 04tf ndl be reproduced andfor distrbuted except with express approval of Alpha Tne use er our name and test results must receive our written approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens ALPHA /TESTING 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR: Mira Enterprises Eastland, Texas (PROJECT: Sonic Restaurant Coppell, Texas 135 130 125 110 105 100 1116- 0% 0% Our lest OUR REPORT NO.: 161578-1 DATE: 07/01/16 MATERIAL DESCRIPTION: DARK BROWN CLAYEY SAND WITH CRUSHED CONCRETE CLASSIFICATION: SC SAMPLE LOCATION: 15'N x 30'W FROM SE CORNER (COPPELL, TX) TEST METHOD: ASTM D698 -B SOIL ID NUMBER: 1 MAXIMUM DRY UNIT WEIGHT: 118.8 PCF OPTIMUM MOISTURE CONTENT: 11.1 % LIQUID LIMIT: 32 PLASTIC LIMIT: 12 PLASTICITY INDEX: 20 % FINER THAN NO. 200 SIEVE: 32% MOISTURE DENSITY RELATIONSHIP 5% 10% 15% 20% 25% 30% MOISTURE CONTENT Respectfully Submitted. Todd Smith ALPHA TESTING, INC. are for the Rou%ve use of the r-01(and thairdosignaled retfplents on mein our and" not be repfoducad and/or dis"tdod eximot via express owrovol of Alpha. The name and test results must receive our written approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. 35% I ALPHA /XTESTING DAILY FIELD 2209 Wisconsin Street, Suite 100 REPORT Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR: Mira Enterprises DATE: 08/13/16 Eastland, Texas PROJECT: Sonic Restaurant OUR REPORT NO.: 161578-16 Coppell, Texas TECHNICIAN: A. Saha WEATHER: Sunny TEMPERATURE RANGE: 70 to 80 degrees The Alpha technician traveled to the above referenced site to monitor ongoing work and perform field testing as requested - 4 of 4 x 8 molds were dropped for Slab on Grade at East Patio Our taorronu@ and reports are for the.nluu.. Uot dt7 test results must receive m—wdae,,---- r__.___.., in our oScdj and shpt[ not be Respectfully Submitted, ,,1� /t . {f a Todd Smith ALPHA TESTING, INC. expressappr—IMA.'all.t Th.iieonin— . ' 1---r,- — a ampler reared and/orobserved,and are notindicalive oflhe qualites ofapparentlyidentical or similar specimens ALPNA +%TESTING 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 REPORT OF REINFORCING Geotechnical I Construction Materials I Environmental www.alphatesting.com STEEL OBSERVATION TBPE Firm No. 813 TESTED FOR: PROJECT: Mira Enterprises Eastland, Texas Sonic Restaurant Coppell, Texas DRAWINGS UTILIZED (SHEETS/DETAILS/DATE): S1.01 / Slab on Grade / 06-27-16 S2.01 / Foundation / 05-27-16 LOCATIONS/ITEMS OBSERVED: East Side Patio TEST METHOD: VISUAL OBSERVATION DATE: 08/13/16 OUR REPORT NO.: 161578-18 PROJECT DATA REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT PLACING DRAWINGS APPROVED X IBAR LENGTH AND SPACE X COLUMN TIE SPACING & TYPE N/A 13AR SIZE X (PROPER BAR PLACEMENT X 13TIRRUP SPACING & TYPE N/A 13AR GRADE X IPROPERLY TIED X TENDON NO. & SPACING N/A REBAR CLEAN X DOWEL BARS IN PLACE X WELDED SPLICES N/A 1=ORM CLEAN X PROPER BAR SUPPORTS I X I IMECHANICAL SPLICES N/A IVO. OF BARS X PROPER COVER X LAPPED SPLICES N/A DISCREPANCIES/COMMENTS: TECHNICIAN: A. Saha Respectfully Submitted, r� 1 � Todd Smith ALPHA TESTING, INC Ourtest results and reports are for the exclusive use of the Client (and their designated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA The use of our name and test results must receive ourwritlen approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Alpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 Tested For: MIRA ENTERPRISES ATTN: MIKE BATTEAS 9500 IH 20 EASTLAND, TX 76448 Fax Number: (254) 629-0978 Project Desc: SONIC RESTAURANT 201 NORTH DENTON TAP ROAD FIELD DATA Placement Location: FIRE LANE: NORTH SIDE OF BUILDING Sample Location: 50'N & 20'W FROM NE CORNER OF BUILDING Date Placed: 8/4/2016 Time Placed: 7:30 AM Cast By: ALPHA Lab Result Concrete Temp (F): 81 Slump (ASTM C-143): 4.0 Air Content: 4.5 Ambient Temp (F): 68 Unit Weight: N/A Lab Cure Break No.: Type: Type: 25 LAB 2 26 LAB (ASTM C-231) Date Issued: 08/11/2016 Our Report #: 161578-15 PM: TODD SMITH Concrete Supplier: BURNCO Plant Number: 506 Delivery Ticket No.: 50413292 Batch Time: 6:32:00 AM Mix ID: 35U500BG Submitted By: Saha, Ashoke Date Received: 8/5/2016 Cured Specification: ASTM C-31 Specified Strength: 3500 CYLINDER COMPRESSION TEST RESULTS Cap Date Age Avg. Avg. Avg Depth/ Area: Max Spec: Tested. (Days): Length Width Diameter Sq. In. Load: PSI: C-1231 8/11/2016 7 8 N/A 4 12.56 29064 2310 C-1231 9/1/2016 28 8 N/A 4 12.56 0 E28 LAB C-1231 9/1/2016 28 8 N/A 4 12.56 0 LAB C-1231 9/1/2016 28 8 N/A 4 12.56 0 CC: Respectfully Submitted By: of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231Specification and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 246043 tXAlpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 Tested For: MIRA ENTERPRISES ATTN: MIKE BATTEAS 9500 IH 20 EASTLAND, TX 76448 Fax Number: (254) 629-0978 Project Desc: SONIC RESTAURANT 201 NORTH DENTON TAP ROAD Date Issued: 08/10/2016 Our Report #: 161578-13 PM: TODD SMITH FIELD DATA Placement Location: FIRE LANE, WEST SIDE OF BUILDING Sample Location: 45'E & 20'N FROM SW CORNER OF BUILDING Date Placed: 8/3/2016 Concrete Supplier: BURNCO Time Placed: 9:30 AM Plant Number: 506 Cast By: ALPHA Delivery Ticket No.: 50413006 CC: Respectfully Submitted By: of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar ' = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245703 Result Batch Time: 8:29:00 AM Concrete Temp (F): 84 Mix ID: 35U500BG Slump (ASTM C-143): 5.0 Submitted By: Saha, Ashoke Air Content: 4.0 (ASTM C-173) Date Received: 8/4/2016 Ambient Temp (F): 78 Cured Specification: ASTM C-31 Unit Weight: N/A Specified Strength: 3500 CYLINDER COMPRESSION TEST RESULTS Lab Cure Break Cap Date Age Avg. Avg. Avg Depth/ Area: Max No.: Type: Type: Spec: Tested: (Days): Length Width Diameter Sq. In. Load: PSI: 17 LAB 2 C-1231 8/10/2016 7 8 N/A 4 12.56 30490 2430 18 LAB C-1231 8/31/2016 28 8 N/A 4 12.56 0 19 LAB C-1231 8/31/2016 28 8 N/A 4 12.56 0 20 LAB C-1231 8/31/2016 28 8 N/A 4 12.56 0 CC: Respectfully Submitted By: of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar ' = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245703 ALPHA /TESTING Dallas, Texas s7522tr9et, Suite 100 REPORT OF REINFORCING Geotechnical I Construction Materials I Environmental STEEL OBSERVATION www.alphatesting.com TBPE Firm No. 813 TESTED FOR: Mira Enterprises DATE: 08/02/16 Eastland, Texas PROJECT: Sonic Restaurant OUR REPORT NO.: 161578-10 Coppell, Texas DRAWINGS UTILIZED (SHEETS/DETAILS/DATE): C7.1 Section of Pavina Details / 05-23-16 LOCATIONS/ITEMS OBSERVED; Canopy Area at North Side of Build Paving at NW Corner of Buildinq TEST METHOD: VISUAL OBSERVATION PROJECT DATA REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT PLACING DRAWINGS APPROVED X BAR LENGTH AND SPACE X COLUMN TIE SPACING & TYPE N/A IBAR SIZE X PROPER BAR PLACEMENT X STIRRUP SPACING & TYPE N/A IBAR GRADE X PROPERLY TIED X 'TENDON NO. & SPACING N/A REBAR CLEAN X DOWEL BARS IN PLACE X WELDED SPLICES N/A 17ORM CLEAN X (PROPER BAR SUPPORTS X MECHANICAL SPLICES N/A IVO. OF BARS X (PROPER COVER X ZAPPED SPLICES N/A DISCREPANCIES/COMMENTS: TECHNICIAN: A. Saha Respectfully Submitted, Todd Smith ALPHA TESTING, INC. Our test results and reports are for the exclusive use of the Client (and their designated reoplenls on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA. The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. Alpha Testing, Inc. 2209 Wisconsin St. Concrete Compression Test Dallas, TX 75229 (972)620-8911 Report TBPE Firm No. 813 Tested For: MIRA ENTERPRISES ATTN: MIKE BATTERS 9500 IH 20 EASTLAND, TX 76448 Fax Number: (254) 629-0978 Project Desc: SONIC RESTAURANT Date Issued: 08/04/2016 Our Report #: 161578-8 PM: TODD SMITH 201 NORTH DENTON TAP ROAD CYLINDER COMPRESSION TEST RESULTS FIELD DATA Lab No.: Cure Type: Placement Location: SIDEWALK: NORTH & SOUTH SIDE ALONG BUILDING Age (Days): Avg. Length Sample Location: 20'W & 1'N FROM NE CORNER OF BUILDING Area: Sq. In. Max Load: PSI: Date Placed: 7/28/2016 Concrete Supplier: BURNCO Time Placed: 1:00 PM Plant Number: 506 Cast By: ALPHA Delivery Ticket No.: 50411763 C-1231 Result Batch Time: 12:08:00 PM Concrete Temp (F): 83 Mix ID: 35U500BG Slump (ASTM C-143): 4.5 Submitted By: Saha, Ashoke Air Content: 5.0 (ASTM C-231) Date Received: 7/29/2016 Ambient Temp (F): 78 Cured Specification: ASTM C-31 Unit Weight: N/A Specified Strength: 3500 CC: Respectfully Submitted By: of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar ` = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245083 CYLINDER COMPRESSION TEST RESULTS Lab No.: Cure Type: Break Cap Type: Spec: Date Tested: Age (Days): Avg. Length Avg. Width Avg Depth/ Diameter Area: Sq. In. Max Load: PSI: 9 LAB 5 C-1231 8/4/2016 7 8 N/A 4 12.56 29840 2380 10 LAB C-1231 8/25/2016 28 8 N/A 4 12.56 0 11 LAB C-1231 8/25/2016 28 8 N/A 4 12.56 0 12 LAB C-1231 8/25/2016 28 8 N/A 4 12.56 0 I l CC: Respectfully Submitted By: of Alpha Testing, Inc. Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar ` = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 245083 ALPHA #XTESTING REPORT OF FIELD 2209 Wisconsin Street, Suite 100 COMPACTION TESTS Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR: PROJECT: TEST DATA: Mira Enterprises Eastland, Texas Sonic Restaurant Coppell, Texas DATE: 07/14/16 OUR REPORT NO.: 161578-5 TECHNICIAN: A. Saha TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY PCF IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT" 5 07/14/16 FG 2 10.7 117.3 11.5 114 97 1-A 6 07/14/16 FG 2 10.7 117.3 11.0 115 98 1-A 7 07/14/16 FG 2 10.7 117.3 10.9 115 98 1-A TEST LOCATION: Parking Lot 5 25'E and 25' N from NW Corner of Building 6 50' E and 25' N from NW Corner of Buildin 7 20'W and 25' N from NE Corner of Building 1 FILL *A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2 NATURAL SUBGRADE B PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Respectfully Submitted, 4. CEMENT TREATED D. RETEST Todd Smith ALPHA TESTING, INC. Our test results and reports are for the exclusive use or the Client (and the irdesignated recipients on file in our office) and shall not be reproduced and/or distributed except with express approval of ALPHA The use of our name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicalive of the qualities of apparently identical or similar specimens ALPHA /TESTING 2209 Wisconsin Street, Suite 100 Dallas, Texas 75229 Geotechnical I Construction Materials I Environmental www.alphatesting.com TBPE Firm No. 813 TESTED FOR: Mira Enterprises Eastland, Texas PROJECT: Sonic Restaurant Coppell, Texas TECHNICIAN: Jeff Utlev 135 130 125 110 105 100 L- 0% OUR REPORT NO.: 161578-2 DATE: 07/01/16 MATERIAL DESCRIPTION: DARK BROWN CLAYEY SAND SOME CRUSHED CONCRETE CLASSIFICATION: SC SAMPLE LOCATION: 100'N x 20'W FROM SE CORNER (COPPELL, TX) TEST METHOD: ASTM D698 -B SOIL ID NUMBER: 2 MAXIMUM DRY UNIT WEIGHT: 117.3 PCF OPTIMUM MOISTURE CONTENT: 10.7 % LIQUID LIMIT: 31 PLASTIC LIMIT: 12 PLASTICITY INDEX: 19 % FINER THAN NO. 200 SIEVE: 82% MOISTURE DENSITY RELATIONSHIP 5% 10% are fof the evdusrve use of thg Client {and their dosigna.ted reap n[5 on NO in 15% 20% MOISTURE CONTENT riot 25% 30% R�ectfully Submitted, � C/�/"� Todd Smith ALPHA TESTING, INC. uletl e%C®AI with eXAreSS.YbbrMl of Aldha. The name and test results must receive our written approval. Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. 35% 135 130 125 r.. 7 v N :2 120 H 2 i7 W ~ 115 Z } Ir 110 105 100 111- 0% results and feporls are to( the w%fdusive use MOISTURE DENSITY RELATIONSHIP 5% 10% 15% 20% 25% 30% 35% MOISTURE CONTENT Res ectfully Submitted, Todd Smith ALPHA TESTING, INC. of the Cilettl {and their desi¢nalad mcipieats on file in ouroihtel and shall nor he fapmducad andfor dielfalpted extent wen exoress A erne! n}.wnnn n—uw nl ni it name and test results must receive our written approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens. ALPHA #NJESTING OUR REPORT NO.: 161578-1 DATE: 07/01/16 2209 Wisconsin Street, Suite 100 MATERIAL DESCRIPTION: DARK BROWN CLAYEY SAND WITH Dallas, Texas 75229 CRUSHED CONCRETE Geotechnical I Construction Materials I Environmental CLASSIFICATION: SC www.alphatesting.com SAMPLE LOCATION: 15'N x 30'W FROM SE CORNER (COPPELL, TBPE Firm No. 813 TX) TEST METHOD: ASTM D698 -B TESTED FOR: Mira Enterprises SOIL ID NUMBER: 1 Eastland, Texas MAXIMUM DRY UNIT WEIGHT: 118.8 PCF OPTIMUM MOISTURE CONTENT: 11.1 % LIQUID LIMIT: 32 PROJECT: Sonic Restaurant PLASTIC LIMIT: 12 Coppell, Texas PLASTICITY INDEX: 20 % FINER THAN NO. 200 SIEVE: 32% TECHNICIAN: Jeff Utlev 135 130 125 r.. 7 v N :2 120 H 2 i7 W ~ 115 Z } Ir 110 105 100 111- 0% results and feporls are to( the w%fdusive use MOISTURE DENSITY RELATIONSHIP 5% 10% 15% 20% 25% 30% 35% MOISTURE CONTENT Res ectfully Submitted, Todd Smith ALPHA TESTING, INC. of the Cilettl {and their desi¢nalad mcipieats on file in ouroihtel and shall nor he fapmducad andfor dielfalpted extent wen exoress A erne! n}.wnnn n—uw nl ni it name and test results must receive our written approval Test results and reports apply only to the samples tested and/or observed, and are not indicative of the qualities of apparently identical or similar specimens.