Loading...
Duke Freeport-LR160912LETTER OF TRANSMITTAL TO: ATTN: JOB NO.: DATE: RE: PERMIT #: LOCATION: We are enclosing: Attached Materials Engineering Division Concrete Reports:As Requested CC: By: For Your Use 09/12/2016 Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 006710A Mr. Sean Jeanes, P.E. LEED AP Duke Realty South/W est Region 14241 North Dallas Parkway, Suite 1000 Dallas, TX 75254 Duke Realty - Todd Henry Duke Realty - Glen Stevenson Mark R. Zortman, P.E. Principal Engineer Pacheco Koch Consulting Engineers - Clayton J. Strolle, City of Coppell - Matt Mabry Weir Bros., Inc. - Mike W eir Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Timothy Tarbutton Project Manager 74, 88, 89, 90 CONCRETE, GROUT, AND MORTAR TESTS3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] X X X X Dallas County SEP 12 2016 POSSIBLE LOW 28-DAY TEST RESULTS REPORTS 89 ECS Texas, LLP Texas Registered Engineering Firm # F-8461 This report (and any included attachments) shall not be reproduced, except in full, without the prior written approval of ECS. Texas Registered Engineering Firm # F-8461 4000 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 74 08/11/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:A 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Area inlet at Storm Line ST-1A Redi-Mix Concrete 1302 25375511 10L11524 4000 psi 07:48AM 0Added W ater: 90º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Jean Habyarimana 08:30AM 3.75 in. 3.20 % (P) Tested by: 95º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 38804905014006008/18/2016 7 Lab 4.01 12.62 3 TT02U 45105701614006109/08/2016 28 Lab 4.01 12.62 2 TT02U 46805912714006209/08/2016 28 Lab 4.01 12.62 3 TT02U 49806294414006309/08/2016 28 Lab 4.01 12.62 3 TT02U 140064 10/06/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/12/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 4000 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 88 09/01/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:A 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Approach from Freeport Parkway LMC 0235 76830609 1701 4000 psi 06:36AM 0Added W ater: 83º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Alex Daniel Cook 07:20AM 5.00 in. 6.00 % (P) Tested by: 78º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 30003793314143109/08/2016 7 Lab 4.01 12.62 2 TT02U 141432 09/29/2016 28 Lab 141433 09/29/2016 28 Lab 141434 09/29/2016 28 Lab 141435 10/27/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/12/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 4000 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 89 09/01/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:B 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Approach from Freeport Parkway LMC 7069 76830615 1701 4000 psi 07:15AM 0Added W ater: 83º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Alex Daniel Cook 08:00AM 4.50 in. 6.00 % (P) Tested by: 79º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 25803253914143709/08/2016 7 Lab 4.01 12.62 3 TT02U 141438 09/29/2016 28 Lab 141439 09/29/2016 28 Lab 141440 09/29/2016 28 Lab 141441 10/27/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other POSSIBLE LOW 28-DAY TEST RESULTS Print Date:09/12/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 3000 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 90 09/01/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:C 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Flatwork LMC 1407 76830632 5177 3000 psi 09:01AM 0Added W ater: 86º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Alex Daniel Cook 09:40AM 5.00 in. 3.50 % (P) Tested by: 80º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 23502969714144309/08/2016 7 Lab 4.01 12.62 3 TT02U 141444 09/29/2016 28 Lab 141445 09/29/2016 28 Lab 141446 09/29/2016 28 Lab 141447 10/27/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/12/2016 TT02 BR01