Sonic-LR160909Concrete Compression Test Report 2209 Wisconsin St. Dallas, TX 75229 (972)620-8911 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:NORTHEAST CORNER OF APPROACH Project Desc:SONIC RESTAURANT 201 NORTH DENTON TAP ROAD Our Report #:161578-17 MIRA ENTERPRISES 9500 IH 20 EASTLAND, TX 76448 MIKE BATTEASATTN: (254) 629-0978Fax Number: Date Placed:8/12/2016 Time Placed:N/A N/A N/A N/A N/A Date Received:8/13/2016 Concrete Supplier:N/A Submitted By:CONTRACTOR Plant Number:B1 Delivery Ticket No.:N/A N/A Batch Time:N/A Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS Avg. Length Avg. Width Avg Depth/ Diameter Cast By:CONTRACTOR Cured Specification:ASTM C-31 Mix ID:N/A Break Type: Sample Location:N/A PM:TODD SMITH Date Issued:09/09/2016 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 29 8/19/2016 7 5009612.56 3990LABC-1231 8 N/A 42 30 9/9/2016 28 5853012.56 4660LABC-1231 8 N/A 42 31 9/9/2016 28 5842412.56 4650LABC-1231 8 N/A 42 32 9/9/2016 28 5985112.56 4770LABC-1231 8 N/A 42 Average 28-day Compressive Strength is compliant with project specifications Notes:All information other than the test results was furnished by others and assumed to be correct. Ashoke Saha picked up the cylinders. CC: 4690 Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 247011 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.