Loading...
Duke Freeport-LR160921LETTER OF TRANSMITTAL TO: ATTN: JOB NO.: DATE: RE: PERMIT #: LOCATION: We are enclosing: Attached Materials Engineering Division Concrete Reports:As Requested CC: By: For Your Use 09/21/2016 Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 006710A Mr. Sean Jeanes, P.E. LEED AP Duke Realty South/W est Region 14241 North Dallas Parkway, Suite 1000 Dallas, TX 75254 Duke Realty - Todd Henry Duke Realty - Glen Stevenson Mark R. Zortman, P.E. Principal Engineer Pacheco Koch Consulting Engineers - Clayton J. Strolle, City of Coppell - Matt Mabry Weir Bros., Inc. - Mike W eir Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Timothy Tarbutton Project Manager 57, 82, 83, 79, 80, 81 CONCRETE, GROUT, AND MORTAR TESTS3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] X X X X Dallas County SEP 21 2016 ECS Texas, LLP Texas Registered Engineering Firm # F-8461 This report (and any included attachments) shall not be reproduced, except in full, without the prior written approval of ECS. Texas Registered Engineering Firm # F-8461 3000 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 57 07/25/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:A 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Footing at ramp LMC 7067 63104089 5150 3000 psi 09:39AM 0Added W ater: 90º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Edward Sesay 10:18AM 5.00 in. 1.20 % (P) Tested by: 86º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 25903271213871808/01/2016 7 Lab 4.01 12.62 3 TT02U 30703855213871908/22/2016 28 Lab 4.00 12.56 3 TT02U 30003788013872008/22/2016 28 Lab 4.01 12.62 3 TT02U 29803759213872108/22/2016 28 Lab 4.01 12.62 3 TT02U 32004036813872209/19/2016 56 Lab 4.01 12.62 2 TT02U FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: X Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/21/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 3600 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 82 08/22/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:A 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Pavement Pour 7 LMC 1420 76830113 5409 3600 psi 07:53AM 0Added W ater: 83º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Sheikh T. Njie 08:15AM 4.00 in. 4.20 % (P) Tested by: 83º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 34004295114068708/29/2016 7 Lab 4.01 12.62 3 TT02U 32604114814068808/29/2016 7 Lab 4.01 12.62 3 TT02U 43605504114068909/19/2016 28 Lab 4.01 12.62 3 TT02U 45905793414069009/19/2016 28 Lab 4.01 12.62 3 TT02U 140691 10/17/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/21/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 3600 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 83 08/22/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:B 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Pavement Pour 7 LMC 0249 76830121 5409 3600 psi 08:56AM 0Added W ater: 83º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Sheikh T. Njie 09:15AM 6.00 in. 4.10 % (P) Tested by: 83º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 33704259114069208/29/2016 7 Lab 4.01 12.62 3 TT02U 31703981814069308/29/2016 7 Lab 4.00 12.56 3 TT02U 43405450714069409/19/2016 28 Lab 4.00 12.56 3 TT02U 42605377114069509/19/2016 28 Lab 4.01 12.62 3 TT02U 140696 10/17/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/21/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 3500 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 79 08/22/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:C 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Pour Strips and Slab on grade Replacement Panels. LMC 0308 76830114 1418 3500 psi 08:00AM 0Added W ater: 83º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Sheikh T. Njie 08:23AM 6.00 in. 1.30 % (P) Tested by: 83º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 32004025614067208/29/2016 7 Lab 4.00 12.56 3 TT02U 29803749914067308/29/2016 7 Lab 4.00 12.56 3 TT02U 39104917414067409/19/2016 28 Lab 4.00 12.56 3 TT02U 40905169514067509/19/2016 28 Lab 4.01 12.62 3 TT02U 140676 10/17/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/21/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 3500 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 80 08/22/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:D 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Pour Strips and Slab on grade Replacement Panels. LMC 7003 76830131 1418 3500 psi 11:37AM 40 Gals.Added W ater:Time Added:12:30PM 86º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Sheikh T. Njie 12:38PM 6.00 in. 1.00 % (P) Tested by: 86º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 31003894014067708/29/2016 7 Lab 4.00 12.56 3 TT02U 31603996114067808/29/2016 7 Lab 4.01 12.62 3 TT02U 41605232914067909/19/2016 28 Lab 4.00 12.56 2 TT02U 42005305514068009/19/2016 28 Lab 4.01 12.62 3 TT02U 140681 10/17/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/21/2016 TT02 BR01 Texas Registered Engineering Firm # F-8461 4000 psiProject: Location:Report No.: Design Strength: Cast Date: Tohatsu NEC Bethel Road and Freeport Parkway, Coppell, TX 81 08/22/2016 6710-AProject : Concrete Cylinders Strength Report Set Designation:E 3033 Kellway Drive, Suite 110 Carrollton, TX 75006 (972) 392-3222 [Phone] (214) 483-9684 [Fax] ECS Texas, LLP Owner: Struc. Eng.: Client: Gen. Contr.: Conc. Contr.: Placement Location: Concrete Supplier:Truck No: Mix Designation: Ticket No: Mix Strength:Batch Time: Arch.: Duke Realty - Sean Jeanes, P.E. LEED Meinhardt & Associates - David Meinhardt LJB inc - Jim Lintz Duke Realty - Glen Stevenson Approach from Freeport Parkway LMC 1407 76830132 1701 4000 psi 12:27PM 0Added W ater: 86º F Air Content:Temperature - Air:Concrete: Time Sampled:Slump: Sample No Test Date Test Age Type Cure Breaking Load,lbs Compr. Str.,psi Brk Type Review by FIELD TEST DATA:Sheikh T. Njie 12:58PM 4.00 in. 4.80 % (P) Tested by: 86º F Average Measured Diameter in. Avg. Measured Cross-Sectional Area in.-sq Cap Type 36004527014068208/29/2016 7 Lab 4.00 12.56 3 TT02U 35604492914068308/29/2016 7 Lab 4.01 12.62 3 TT02U 45605756814068409/19/2016 28 Lab 4.01 12.62 3 TT02U 46805909414068509/19/2016 28 Lab 4.01 12.62 3 TT02U 140686 10/17/2016 56 Lab FIELD CURING CONDITIONS: Curing Box Insulated Heated Cooled Caps Remarks: Final Review By: Sampling in accordance with (iaw) ASTM C172, except that samples may have been taken from the beginning of the load after a minimum discharge of approximately one cubic yard. Cylinder molding and laboratory curing iaw ASTM C31, compressive strength test and break type iaw ASTM C39, slump iaw C143, air content iaw ASTM C173 (V) or C231 (P), temperature iaw ASTM C1064, and unit weight iaw ASTM C138. Cylinders denoted with Cap Type U are tested using unbonded caps iaw ASTM C1231, cylinders denoted with Cap Type B are tested using bonded caps iaw ASTM C617. Break Types are classified as: Type 1, 2, 3, 4, 5, or 6 iaw C39. No Curing BoxX Ice Other Print Date:09/21/2016 TT02 BR01