Loading...
Park West Crossing-LR160927 STRUCTURAL STEEL OBSERVATIONS REPORT Report Number:94151183.0292 * Report Contains Deviation(s) Service Date:09/27/168901 Carpenter Fwy Ste 100 Report Date:09/29/16 Dallas, TX 75247-4547 214-630-1010 Reg No: F-3272 ClientProject ML Realty PartnersPark West Crossing - Phase 2 Attn: Timothy GeislerSEC Freeport Pkwy & Southwestern Blvd One Pierce Pl Ste 450WCoppell, TX Itasca, IL 60143 Project Number: 94151183 On this date, Terracon's representative arrived at the above referenced job site as scheduled for structural steel observations. A visual observation was performed as noted below. A.Building E, Foundation Level, Tilt Wall Panel To Pier. Re-observation Item From Report 94151183.0289: 1.Tilt wall panel to pier cap welded connections were now determined to be compliant. Yet the north wall leaveout panel still not set. B.Building E, Roof Level Framing @ E-K/1-4: *1.Column anchor bolts, two (2) locations were found to have missing nuts. 2.Joist and girder seat welds were determined to be compliant. *3.Joist bridging not complete at the end wall attachments. *4.Joist seat support lug weldments at the tilt wall panel embed plates were determined to be compliant. Yet two (2) locations, the slip bolted stud panel joint connections were found to be incomplete. C.Building F, Foundation Level, Tilt Wall Panel To Pier: *1.Tilt wall panel to pier cap welded connection were determined to be compliant, with the following two (2) exceptions *a.South wall, one (1) location not welded. *b.East wall, leaveout panel not set. *Noted discrepancies and/or incomplete work. Services: Structural steel observations. Terracon Rep.: Randy T. Walcker, C.W.I. Reported To: Contractor:Structure Tone Southwest Report Distribution: (1) ML Realty Partners, Timothy Geisler(1) City of Coppell TX, Matthew Mabry (1) Halff Associates Inc, Hunter Starkey(1) ML Realty Partners, John Benson Reviewed By:____________________________________ (1) O?Brien Architects , Richard Nordyke(1) Structure Tone Southwest Inc., Damon James D. Baze Renaud (1) Structure Tone Southwest Inc., Robin (1) TechniStructures, Jason Owens Project Manager Povey The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1sbv BC0001, 10-16-13, Rev.10