Loading...
Forest Cove 2-LR 980613ALPHA TESTING, INC. 2209 Wisconsin St,, Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR PACIFIC UNITED DEV. CORP. DATE 6/13/98 C/O ROBERT POPE & ASSOC. PIANO, TEXAS PROJECT FOREST COVE ESTATES OUR REPORT NO. 98018-75 PHASE 1 & 2 COPPELL, TEXAS TEST )ATA: TEST ~. ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPT~,~,~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 491 6/13/98 FG-1.7 1 17.2 107.4 20.4 103 96 1-A 492 6/13/98 FG-1.0 1 17.2 107.4 18.5 105 97 1-A 493 6/13/98 FG-1.5 1 17.2 107.4 18.5 104 96 1-A 494 6/13/98 FG-1.7 1 17.2 107.4 18.5 105 97 1 -A 495 6/13/98 FG-1.5 1 17.2 107.4 18.8 104 97 1-A 496 6/13/98 FG-1.8 I 17.2 107.4 19.5 103 96 1-A 497 6/13~98 FG-0.7 1 17.2 107.4 17.9 103 96 1-A TEST LOCATION: 491 BLOCK"A" PAD #33 PHASE II 492 BLOCK "A" PAD #34 PHASE II 493 BLOCK "A" PAD #-35 PHASE II 494 BLOCK "A" PAD #36 PHASE II 495 BLOCK "A" PAD #37 PHASE II 496 BLOCK"A" PAD #38 PHASE II 497 BLOCK"A" PAD #12 PHASE II I FILL 2 NATURAL SUSGRADE 3 LIME STABILIZED 4. CEMENT TREATED * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D RETEST Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting ALPHA TESTING, INC. 2209 Wisconsin St,, Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR PACIFIC UNITED DEV. CORP. C/O ROBERT POPE & ASSOC. PIANO, TEXAS DATE 6/13/98 PROJECT FOREST COVE ESTATES PHASE 1 & 2 COPPELL, TEXAS OUR REPORT NO. 98018-75A TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPT~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF i 498 6/13/98 FG-0.5 1 17.2 107.4 18.2 106 99 1 -A 499 6/13~98 FG-0.6 I 17.2 107.4 20.7 105 97 1-A 500 6/13/98 FG-0.6 I 17.2 107.4 17.5 106 99 1-A 501 6/13/98 FG-0.5 I 17.2 107.4 18.6 105 97 1-A 502 6/13~98 FG-0.5 1 17.2 107.4 18.4 105 97 1 -A TEST LOCATION: 498 BLOCK"A" PAD#13 PHASE II 499 BLOCK"A" PAD #21 PHASE II 500 BLOCK"A" PAD #22 PHASE II 501 BLOCK"A" PAD #23 PHASE II 502 BLOCK"A" PAD #28 PHASE II 1 FILL * A IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS .. 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPEC'FICATIONS Resp/~y Submitt~// 3 LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS Geotechnical Engineering · Construction Materials Testing · Environmental Engineering ·-~onsultlng