Loading...
Forest Cove 2-LR 980603ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REHORT OF FIELD COMPACTION TESTS TESTED FOR PACIFIC UNITED DEV. CORP. CIO ROBERT POPE & ASSOC. PIANO, TEXAS DATE 6/3/98 PROJECT FOREST COVE ESTATES PHASE 1 & 2 COPPELL, TEXAS OUR REPORT NO. 98018-73 TEST DATA: TEST ~ ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPT~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSrI~ COMPACTION COMMENT* % PCF % PCF 450 6/3/98 FG 1 17.2 107.4 19.7 105 98 1-A 451 6/3/98 FG 1 17.2 107.4 18.9 105 98 1-A 452 6~3/98 FG I 17.2 107.4 17.8 107 99 1-A 453 6/3/98 FG 1 17.2 107.4 18.7 105 98 1-A 454 6~3/98 FG I 17.2' 107.4 19.9 105 98 1-A 455 6~3/98 FG I 17.2 107.4 18.9 105 98 1-A 456 6/3~98 FG 2 18.5 105.6 20.7 104 98 1 -A TEST .OCATION: 450 BLOCK"D" PAD #1 PHASE I 451 BLOCK"D" PAD #2 PHASE I 452 BLOCK"D" PAD ~ PHASE I 453 BLOCK"D" PAD ~4 PHASE I 454 BLOCK"D" PAD #5 PHASE I 455 BLOCK"D" PAD ~ PHASE I 456 BLOCK"D" PAD #7 PHASE I 1 FILL 2 NATURALSUBGRADE 3 LIME STABILIZED 4. CEMENTTREATED w A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST Geotechnical Engineedng · Construction Materfals Testing · Environmental Engineering · Consu#fng ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/620-8911 - 972/263-4937 (Metro) FAX: 972/406-8023 RE ORT OF FIELD COMPACTION TESTS TESTED FOR PACIFIC U!NITED DEV. CORP. DATE 6/3/98 C/O ROBERT POPE & ASSOC. PIANO, TEXAS PROJECT FOREST COVE ESTATES OUR REPORT NO. 98018-73A PHASE I & 2 COPPELL, TEXAS TEST DATA: TEST '~. ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPT~ NUMBER MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION COMMENT* % PCF % PCF 457 6/3/98 FG 2 18,5 105.6 20.1 103 98 1 -A 458 6/3/98 FG 2 18.5 105.6 19.2 105 99 1 -A 459 6/3/98 FG 2 18.5 105.6 18.8 105 100 1 -A 460 6/3/98 FG 2 18.5 105.6 20.0 103 98 1 -A 461 6/3/98 FG 2 18.5 105.6 18.9 103 97 1-A 462 6/3/98 FG 2 18.5 105.6 20.0 105 99 1-A 463 6/3/98 FG 2 18.5 105.6 20.0 104 98 1 -A TEST LOCATION: 457 BLOCK"D" PaD #8 PHASE I 458 BLOCK"D" PAD#9 PHASE I 459 BLOCK "D" PAD #11 PHASE I 460 BLOCK "D" PAD #13 PHASE I 461 BLOCK"D" PAD #14 PHASE I 462 BLOCK "D" PAD #15 PHASE I 463 BLOCK"D" PAD #16 PHASE I 1 FILL 2 NATURALSUBGRADE 3 LIME STABILIZED 4. CEMENTTREATED w A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLYWITH SPECIFICATIONS C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D. RETEST Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 972/62G8911 - 972/263-4937 (Metro) FAX: 972/406-8023 REPORT OF FIELD COMPACTION TESTS TESTED FOR PACIFIC UNITED DEV. CORP. DATE 6/3/98 CIO ROBERT POPE & ASSOC. PIANO, TEXAS PROJECT FOREST COVE ESTATES OUR REPORT NO. 98018-73B PHASE I & 2 COPPELL, TEXAS TEST DATA: TEST '~. ELEV. SOIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT NO. DATEDEPT~,~ NUMBER MOISTURE DRYDENSITY MOISTURE DRYDENSITY COMPACTION COMMENT* % PCF % PCF 464 6/3/98 FG 2 18.5 105.6 20.2 105 99 1 -A 465 6~3/98 FG 2 18.5 105.6 19.8 104 98 1-A 466 6/3/98 FG I 17.2 107.4 18.5 107 99 1 -A 467 6/3/98 FG I 17.2 107.4 19.0 106 99 1-A 468 6/3/98 FG 1 17.2 107.4 18.2 106 99 1-A 469 6/3/98 FG 1 17.2 107.4 17.8 106 99 1-A 470 6/3/98 FG 1 17.2 107.4 18.0 107 99 1-A TEST LOCATION: 464 BLOCK "D" PAD #17 PHASE I 465 BLOCK "D" PAD #18 PHASE I 466 BLOCK"B" PAD #1 PHASE II 467 BLOCK"B" PAD #1 PHASE II 468 BLOCK"B" PAD #2 PHASE II 469 BLOCK "B" PAD #2 PHASE II 470 BLOCK "B" PAD #3 PHASE II I FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4 CEMENT TREATED * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS D RETEST Geotechnical Engineering · Construction Materials Testing · Environmental Engineering · Consulting