Forest Cove 2-LR 980323ALPHA TESTIN ,, iNC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR
PACIFIC UNITED
C/O ROBERT POPE
PLANO, TEXAS
DEV. CORP.
& ASSOC.
DATE 03/23/98
FOREST COVE ESTATES
PROJECT PHASE i & 2 OURREPORTNO. 98018-29
COPPELL, TEXAS
TEST DATA:
TEST DA~ ~,,,,,,~LEV, i ~ OPTIMUM MAXIMUM LAB IN Pt. ACE IN PLACE PERC~T COMMENT*
MOISTUR~ DRY ~ MOISTURE ~Y ~NSITY ~MPAC~
NO, DEp~ .~.~ ~. ~ % eC, F % PCF
281 03/23 FG~i.0 2 18.5 105.6 20.0 101 96 1-A
282 03/23 FG-1.0 2 18.5 105.6 20.5 102 97 1-A
283 03/23 FG-1.0 2 18.5 105.6 20.1 102 97 1-A
!
284 03/23 FG-2.0 i 1 17.2 107.4 19.4 102 95 1-A
I
285 03/23 FG-i.0 i 1 17.2 107.4 18.6 103 96 1-A
I
286 03/23 FG-i.O i 1 17.2 107.4 18.4 104 97 1-A
287 03/23 FG-1.0 i 2 18.5 105.6 19.2 103 98 1-A
I
TEST LOCATION:
281 STORM DRAIN LINE "B" STA. 2+00
282 STORM DRAIN LINE "B" STA. 4+50
283 STORM DRAIN LII~ "B'i STA. 7+00
284 STORM DRAIN LINE "A" STA. 2+50
285 STORM DRAIN LINE "A", STA. 2+40
286 STORM DRAIN LINE A-~ STA. 2+00
287 WATER LII~ SERVICE ~0 BLOCK "C" LOT #8
i
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4. CEMENT TREATED
CG01083-18
* SPECIFICATIONS
A. IN PLACE PERu~:NT MOISTURE AND PERCENT COMPACTION COMPLY WITH ~~
B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~~,,~'
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
D. RETEST , NC.
ALPHA TESTING; INC.
2209 Wisconsin St., iSuite 100
Dallas, Texas 75229i
REPORT OF FIELD
COMPACTION TESTS
(972) 620-8911
I
TESTED FOR PACIFIC UNITED DEV. CORP. DATE 03/23/98
C/O ROBERT POP~ & ASSOC.
PLANO, TEXAS
FOREST COVE ESTATES
PROJECT P~E 1 & 2 OUR REPORT NO. 98018-29A
COPPELL, TEXAS
TEST DATA:
I
SOIL ID o~n~ ~a~x~aua LAS iN PLACE iN m. ACE P~RCEm COMMENT*
TEST DATE ~O~s'ruRE ORY oENSn'Y ~ DRY Dr:NaTY
NO. lUMBER % ~ %
288 03/23 FG-1.0 2 18.5 105.6 19.3 102 97 1-A
!
289 03/23 FG-1.0 2 18 . 5 105.6 20.9 102 97 1-A
TEST LOCATION:
288 WATER LINE SERVICE TO BLOCK "C" LOT #10
289 WATER LII~ SERVICE TO BLOCK "C" LOT #12
I
1. FILL
2. NATURAL SUBGRADE
3, LIME STABILIZED
4. CEMENT TREATED
CG01083-18
PLACE PERChENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS ~'-'- '~
A.
IN
B. PERCENT COMI~ACTION-'- DOES NOT COMPLY WITH SPECIFICATIONS '- '-~,~Res~~itt
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
D, RETEST
D~ S~t~ner