Forest Cove 2-LR 980304ALPHA TESTINCNC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 REPOi-1T OF FIELD COMPACTION TESTS / TESTED FOR PACIFIC UNITED/DEV. CORP. DATE C/O ROBERT POPs & ASSOC. PLANO, TEXAS FOREST COVE ESTATES PHASE 1 & 2 PROJECT COPPELL, TEXAS OUR REPORT NO. 03/04/98 98018-25 TEST DATA: TEST DA~ ~ ~OIL ID OPTIMUM MAX~UM LAB IN PLACE IN PLA~ PERCE~ COMMENT* ~IS~RE Dm ~NS~ ~IS~RE DRY DENS~ COMPACTION NO. flUMBER % ~F % ~:~ 253 03/04 t~3-2.0 3 13.6 113,6 14.9 108 95 1-A 254 03/04 [:~.3-1.0 3 13.6 113,6 14.2 108 95 1-A 255 03/04 FG-2.0 2 18.5 105.6 19.3 101 96 1-A 256 03/04 FG-1.0 i 2 18.5 105.6 18.8 104 98 1-A 257 03/04 FG-2.0 i 2 18.5 105.6 18.6 103 98 1-A 258 03/04 FG-1.0 i 2 18.5 105.6 19.5 102 97 1-A 259 03/04 FG-2.0 i 2 18.5 105.6 20~0 104 99 1-A TEST LOCATtON: NO STATION FOR WATER LINES I 253 8" WATER LINE ADJACE1TI' TO BLOCK "A" LOT #2 254 8" WATER LINE ADJACENw TO BLOCK "A" LOT #2 255 8" WATER LINE ADJACEITr TO BLOCK "A" LOT #5 256 8" WATER LINE ADJACENT TO BLOCK "A" LOT #5 I 257 8" WATER LINE ADJACENT TO BLOCK "A" LOT #6 S.E. CORNER I 258 8" WATER LINE ADJACENT TO BLOCK "A" LOT #6 S.E. CORNER 1 I 259 8" WATER LINE ADJACENT TO BLOCK "C" LOT #1 ACROSS STREET i 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED CG01083-18 * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS ~ B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS / Respectfully S~bmitted .... TEST "C ,. MO,STU. NOT OO P'Y W,T. ONS / ALPHA TESTIN~'~ 'NC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229! (972) 620-8911 REPOrlT OF FIELD COMPACTION TESTS TESTED FOR PACIFIC UNITED DEV. CORP. C/O ROBERT POP~ & ASSOC. PI.d~O, TEXAS FOREST COVE ESTATES PHASE 1 & 2 PROJECT COPPELL, TEXAS DATE 03/04/98 OUR REPORT NO. 98018-25A TEST DATA: TEST DATE '"'"-...~LEV. .~OIL ID OPTIMUM MAXIMUM LAB IN PLACE IN PLACE PERCENT MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACI'ION COMMENT* NO. DEPTH ~ I~lUMBER % PCF % PCF 260 03/04 FG-1.0 2 18 . 5 105.6 18 . 9 102 96 1-A 261 03/04 FG-2.0 2 18.5 105.6 19.9 102 97 1-A 262 03/04 FG-1.0 2 18.5 105.6 20.1 103 98 1-A I 263 03/04 FG-2.0 ! 2 18.5 105.6 18.6 103 97 1-A 264 03/04 FG-1.0 2 18.5 105 . 6 19.0 104 99 1-A I I TEST LOCATION: 260 8" WATER LINE ADJACENT TO BLOCK "C" LOT #1 ACROSS STREET 261 8" WATER LINE ADJACENT TO BLOCK "D" LOT #8 262 8" WATER LINE ADJACENT TO BLOCK "D" LOT #8 263 8" WATER LII~ ADJACENT TO BLOCK "D" LOT #5 264 8" WATER LINE ADJACENT TO BLOCK "D" LOT #5 1. FILL * A. IN PLACE PERC '-NT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS /~ · 2. NATURAL SUBGRADE B. PERCENT COMF ACTION DOES NOT COMPLY WITH SPECIFICATIONS /Respectfully Subn~itted 3. LIME STABILIZED C. PERCENT IN PL ICE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ........ ' / ' 4. CEMENT TREATED D. RETEST // ALPHA TEST~'/~.~;II~.