Loading...
Forest Cove 2-LR 980202ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 DAILY FIELD REPORT TESTED FOR PACIFIC UNITED DEV. CORP. C/O ROBERT POPE & ASSOC. PLANO, TEXAS DATE 02/02/98 PROJECT FOREST COVE ESTATES PHASE 1 & 2 COPPELL, TEXAS OUR REPORT NO. 98018-19 WEATHER: PARTLY CLoUDy TEMPERATURE RANGE: 5 0 ALPHA Representative: K. C. TO: 60 THE ALPHA TECHNICIAN TRAVELED TO THE ABOVE REFERENCED PROJECT AS REQUESTED TO MONITOR ON-GOING WORK AND PERFORM FIELD TESTING AS REQUESTED. SUBGRADE FOR PADS ~ERED 19 THROUGH 23 ON BLOCK "D" WAS OBSERVEDTOVERIFY THAT AREAS HAD BEEN PREPARED IN GENERAL ACCORDANCE WITH LOCALLY ACCEPTED STANDARDS. A TOTAL OF 16 FIELD DENSITY TESTS WERE PERFORMED ON FILL AND NATURAL ,SUBGRADE SOILS FOR HOUSE PAD AREAS. SEE ATTACHED REPORT OF FIELD COMPACTION TESTS. THE SITE REPRESENTATIVE WAS INFORMED OF ALL OBSERVATIONS AND FIELD TEST RESULTS. AT THE COMPLETION OF SCHEDULED TESTING, THE TECHNICIAN RETURNED TO THE DALLAS OFFICE. CG01083-29 ALPHA TESTIN .,~,, ,4C. ~ REPOr T OF FIELD 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 COMPACTION TESTS (972) 620-8911 TESTED FOR PACIFIC UNITED DEV. CORP. DATE C/O ROBERT POPE & ASSOC. PLANO, TEXAS 02/02/98 FOREST COVE ESTATES PROJECT PHASE i & 2 OURREPO~ NO. 98018-19A COPPELL, TEXAS TEST DATA: ESTNo. DATE ~ NUMBERSOIL ID ~I~'I'uREOPTIMUM% MAXIMUMDRY ~FDENs~LAB MOISTUREIN Pr. ACE% DRyIN~FPt'~OENSrn' CC~e~C'~oNPERCEm COMMENT* 178 02/02 FG 1 17.2 107.4 18.2 104 97 1-A 179 02/02 FG 1 17.2 107.4 17.8 106 99 1-A 180 02/02 FG 1 17.2 107.4 18.5 105 97 1-A 181 02/02 FG 1 17.2 107.4 17.4 107 100 1-A 182 02/02 FG 1 17.2 107.4 19.6 105 98 1-A 183 02/02 FG 1 17.2 107.4 19.8 106 99 1-A 184 02/02 FG 1 17.2 107.4 19.7 105 98 1-A TEST LOCATION: 178 BLOCK "C" PAD #4 179 BLOCK "C" PAD ~5 180 BLOCK "C" PAD #7 181 BLOCK "C" PAD # 9 182 BLOCK "C" PAD #10 183 BLOCK "C" PAD #11 184 BLOCK "C" PAD #12 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED CG01083-18 * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS ~ B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS / Respecff~ly Submitted~.~ C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS /~.~ AL~~C D. RETEST _ · ~d P S~_~tner ALPHA TESTIN~C. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 REPOh OF FIELD COMPACTION TESTS TESTEDFOR PACIFIC UNITED DEV. CORP. DATE 02/02/98 C/O ROBERT POPE & ASSOC. PLANO, TEXAS FOREST COVE ESTATES PR~ECT PHASE 1 & 2 OURREPO~ NO. 98018-19B COPPELL, TEXAS TEST DATA: TEST DATE ~ SOIL ID O{~TIMUM MAXIM~ LAB IN PLACE IN PLACE PERCE~ COMMENT ~ISTURE DRY DEN$~ MOI$~RE DRY DENSlT~ COMPAC'F1ON NO. NUMBER % PCF % PCF 185 02/02 FG 1 17.2 107.4 19.2 105 98 1-A 186 02/02 FG 1 17.2 107.4 17.2 104 96 1-A 187 02/02 SG 4 18.2 104.7 20.5 100 95 1-A 188 02/02 FG 4 18.2 104.7 20.2 103 98 1-A 189 02/02 SG 4 18.2 104.7 19.1 104 100 1-A 190 02/02 FG 4 18.2 104.7 18.9 104 99 1-A 191 02/02 SG 4 18.2 104.7 19.6 104 99 1-A TEST LOCATION: 185 BLOCK "C" PAD #13 186 BLOCK "C" PAD #15 187 BLOCK "D" PAD #19 188 BLOCK "D" PAD #20 189 BLOCK "D" PAD #21 190 BLOCK "D" PAD #22 191 BLOCK "D" PAD #23 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4, CEMENT TREATED CG01083-18 * A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~~f~ly C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ALPHA TESTING~C. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 (972) 620-8911 REPOh "¥ OF FIELD COMPACTION TESTS TESTED FOR PACIFIC UNITED DEV. CORP. C/O ROBERT POPE & ASSOC. PLANO, TEXAS DATE 02/02/98 FOREST COVE ESTATES PROJECT PHASE i & 2 OURREPO~ NO. 98018-19C COPPELL, TEXAS TEST DATA: TEST DATE SOIL ID MOISTuREOPTIMUM MAXIMUMDRY DENSrFyLAB MOISTUREIN PI. ACE DRyIN or=NsrryPLACECO~PACrtoNPERCEN~ COMMENT* NO. NUMBER % PC~ % PCF 192 02/02 FG-0.5 1 17.2 107.4 17.3 104 97 1-A 193 02/02 FG-0 . 7 1 17.2 107.4 19.2 105 98 1-A TEST LOCATION: 192 BLOCK "D" PAD #10 193 BLOCK "D" PAD #12 1. FILL 2. NATURAL SUBGRADE 3. LIME STABILIZED 4. CEMENT TREATED CG01083-18 B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS