Forest Cove 2-LR 980202ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
DAILY FIELD REPORT
TESTED FOR PACIFIC UNITED DEV. CORP.
C/O ROBERT POPE & ASSOC.
PLANO, TEXAS
DATE 02/02/98
PROJECT
FOREST COVE ESTATES
PHASE 1 & 2
COPPELL, TEXAS
OUR REPORT NO.
98018-19
WEATHER: PARTLY CLoUDy
TEMPERATURE RANGE: 5 0
ALPHA Representative: K. C.
TO:
60
THE ALPHA TECHNICIAN TRAVELED TO THE ABOVE REFERENCED PROJECT AS REQUESTED
TO MONITOR ON-GOING WORK AND PERFORM FIELD TESTING AS REQUESTED.
SUBGRADE FOR PADS ~ERED 19 THROUGH 23 ON BLOCK "D" WAS OBSERVEDTOVERIFY
THAT AREAS HAD BEEN PREPARED IN GENERAL ACCORDANCE WITH LOCALLY ACCEPTED
STANDARDS.
A TOTAL OF 16 FIELD DENSITY TESTS WERE PERFORMED ON FILL AND NATURAL
,SUBGRADE SOILS FOR HOUSE PAD AREAS. SEE ATTACHED REPORT OF FIELD COMPACTION
TESTS.
THE SITE REPRESENTATIVE WAS INFORMED OF ALL OBSERVATIONS AND FIELD TEST
RESULTS.
AT THE COMPLETION OF SCHEDULED TESTING, THE TECHNICIAN RETURNED TO THE
DALLAS OFFICE.
CG01083-29
ALPHA TESTIN .,~,, ,4C. ~
REPOr T OF FIELD
2209 Wisconsin St., Suite 100
Dallas, Texas 75229 COMPACTION TESTS
(972) 620-8911
TESTED FOR PACIFIC UNITED DEV. CORP. DATE
C/O ROBERT POPE & ASSOC.
PLANO, TEXAS
02/02/98
FOREST COVE ESTATES
PROJECT PHASE i & 2 OURREPO~ NO. 98018-19A
COPPELL, TEXAS
TEST DATA:
ESTNo. DATE ~ NUMBERSOIL ID ~I~'I'uREOPTIMUM% MAXIMUMDRY ~FDENs~LAB MOISTUREIN Pr. ACE% DRyIN~FPt'~OENSrn' CC~e~C'~oNPERCEm COMMENT*
178 02/02 FG 1 17.2 107.4 18.2 104 97 1-A
179 02/02 FG 1 17.2 107.4 17.8 106 99 1-A
180 02/02 FG 1 17.2 107.4 18.5 105 97 1-A
181 02/02 FG 1 17.2 107.4 17.4 107 100 1-A
182 02/02 FG 1 17.2 107.4 19.6 105 98 1-A
183 02/02 FG 1 17.2 107.4 19.8 106 99 1-A
184 02/02 FG 1 17.2 107.4 19.7 105 98 1-A
TEST LOCATION:
178 BLOCK "C" PAD #4
179 BLOCK "C" PAD ~5
180 BLOCK "C" PAD #7
181 BLOCK "C" PAD # 9
182 BLOCK "C" PAD #10
183 BLOCK "C" PAD #11
184 BLOCK "C" PAD #12
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4. CEMENT TREATED
CG01083-18
* A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS ~
B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS / Respecff~ly Submitted~.~
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS /~.~ AL~~C
D. RETEST _ ·
~d P S~_~tner
ALPHA TESTIN~C.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
REPOh OF FIELD
COMPACTION TESTS
TESTEDFOR PACIFIC UNITED DEV. CORP. DATE 02/02/98
C/O ROBERT POPE & ASSOC.
PLANO, TEXAS
FOREST COVE ESTATES
PR~ECT PHASE 1 & 2 OURREPO~ NO. 98018-19B
COPPELL, TEXAS
TEST DATA:
TEST DATE ~ SOIL ID O{~TIMUM MAXIM~ LAB IN PLACE IN PLACE PERCE~ COMMENT
~ISTURE DRY DEN$~ MOI$~RE DRY DENSlT~ COMPAC'F1ON
NO. NUMBER % PCF % PCF
185 02/02 FG 1 17.2 107.4 19.2 105 98 1-A
186 02/02 FG 1 17.2 107.4 17.2 104 96 1-A
187 02/02 SG 4 18.2 104.7 20.5 100 95 1-A
188 02/02 FG 4 18.2 104.7 20.2 103 98 1-A
189 02/02 SG 4 18.2 104.7 19.1 104 100 1-A
190 02/02 FG 4 18.2 104.7 18.9 104 99 1-A
191 02/02 SG 4 18.2 104.7 19.6 104 99 1-A
TEST LOCATION:
185 BLOCK "C" PAD #13
186 BLOCK "C" PAD #15
187 BLOCK "D" PAD #19
188 BLOCK "D" PAD #20
189 BLOCK "D" PAD #21
190 BLOCK "D" PAD #22
191 BLOCK "D" PAD #23
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4, CEMENT TREATED
CG01083-18
* A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~~f~ly
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
ALPHA TESTING~C.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
REPOh "¥ OF FIELD
COMPACTION TESTS
TESTED FOR
PACIFIC UNITED DEV. CORP.
C/O ROBERT POPE & ASSOC.
PLANO, TEXAS
DATE
02/02/98
FOREST COVE ESTATES
PROJECT PHASE i & 2 OURREPO~ NO. 98018-19C
COPPELL, TEXAS
TEST DATA:
TEST DATE SOIL ID MOISTuREOPTIMUM MAXIMUMDRY DENSrFyLAB MOISTUREIN PI. ACE DRyIN or=NsrryPLACECO~PACrtoNPERCEN~ COMMENT*
NO. NUMBER % PC~ % PCF
192 02/02 FG-0.5 1 17.2 107.4 17.3 104 97 1-A
193 02/02 FG-0 . 7 1 17.2 107.4 19.2 105 98 1-A
TEST LOCATION:
192 BLOCK "D" PAD #10
193 BLOCK "D" PAD #12
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4. CEMENT TREATED
CG01083-18
B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS