Forest Cove 2-LR 980123ALPHA TESTIN(~,~ C.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
DAILY FIELD REPORT
TESTED FOR PACIFIC UNITED DEV. CORP.
C/O ROBERT POPE & ASSOC.
PLANO, TEXAS
D~E 01/23/98
PROJECT
FOREST COVE ESTATES
PHASE 1 & 2
COPPELL, TEXAS
OUR REPORT NO.
98018-12
WEATHER:
PARTLY CLOUDY
TEMPERATURE RANGE: 40 TO: 45
ALPHA Representative: K. C.
THE ALPHA TECHNICIAN TRAVELED TO THE ABOVE REFERENCED PROJECT AS REQUESTED
TO MONITOR ON-GOING WORK AND PERFORM FIELD TESTING AS REQUESTED.
SUBGRADE FOR PADS NUMBERED 9 THROUGH 12 ON BLOCK "D" WAS OBSERVED TO VERIFY
THAT AREAS HAD BEEN PREPARED IN GENERAL ACCORDANCE WITH LOCALLY ACCEPTED
STANDARDS.
A TOTAL OF 14 FIELD DENSITY TESTS WERE PERFORMED ON FILL AND NATURAL
SUBGRADE SOILS FOR HOUSE PAD, ALLEY, AND STREET AREAS. SEE ATTACHED REPORT
OF FIELD COMPACTION TESTS.
THE SITE REPRESENTATIVE WAS INFORMED OF ALL OBSERVATIONS AND FIELD TEST
RESULTS.
AT THE COMPLETION OF SCHEDULED TESTING, THE TECHNICIAN RETURNED TO THE
DALLAS OFFICE.
CG01083-29
ALPHA TESTIN~INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
REP " T OF FIELD
COMPACTION TESTS
TESTED FOR PACIFIC UNITED DEV. CORP. DATE
C/O ROBERT POPE & ASSOC.
PLANO, TEXAS
01/23/98
FOREST COVE ESTATES
PROJECT P~IASE I & 2 OURREPO~NO. 98018-12A
COPPELL, TEXAS
TEST DATA:
TEST DATE SOlL ID ~ ~ IA8 IN PLACE IN PI. ACE PE~E~ COMMENT*
~om-ruRE my ~q~s~ ~:,sru~ ~mY ~srrY COM~CTK)N
NO. NUMBER % m:m % ;,ct=
76 01/23 FG-3.0 2 18.5 105.6 19.6 105 99 1-A
77 01/23 FG-4.0 2 18.5 105.6 21.5 103 97 1-A
78 01/23 FG-6.8 2 18.5 105.6 19.4 105 100 1-A
79 01/23 FG-5.0 2 18.5 105.6 20.1 106 100 1-A
80 01/23 FG-2.0 2 18.5 105.6 19.7 104 98 1-A
81 01/23 FG-6.0 2 18.5 105.6 20.4 103 98 1-A
82 01/23 FG-5.0 2 18.5 105.6 20.0 105 99 1-A
TEST LOCATION:
76 BLOCK "D" PAD ~ 1
77 BLOCK "D" PAD #14
78 BLOCK "D" PAD #15
79 BLOCK "D" PAD # 16
80 CRESTWOOD COVE STA. 1+50
81 ALLEY D-1 STA. 2+00
82 ALLEY D-1 STA. 1+90
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4. CEMENT TREATED
CG01083-18
* A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS /~~~
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
D. RETEST
ALPHA TESTILY, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
REPOT OF FIELD
COMPACTION TESTS
TESTED FOR PACIFIC UNITED DEV. CORP. DATE
C/O ROBERT POPE & ASSOC.
PLANO, TEXAS
01/23/98
FOREST COVE ESTATES
PR~ECT PHASE i & 2' OURREPO~NO. 98018-12B
COPPELL, TEXAS
TEST DATA:
TEST NO. DATE ~ NUMBER SOIL ID MO~S'rURE oPmm~ % ~x#~u~ Dm, PC~ ~Ns~ L~S MOdUlE ~ Pt.~CE % ~W ~ PCF D~Nsrr~ PLACE CO~aPACT~3N ~mT, ENT COMMENT*
83 01/23 FG-5.8 2 18.5 105.6 19.3 105 99 1-A
84 01/23 FG-4.0 2 18.5 105.6 21.7 103 97 1-A
85 01/23 FG-4.8 2 18.5 105.6 20.3 104 98 1-A
86 01/23 FG-4.0 2 18.5 105.6 20.2 105 99 1-A
87 01/23 FG-3.0 2 18.5 105.6 21.8 103 98 1-A
88 01/23 SG 1 17.2 107.4 19.9 106 99 2-A
89 01/23 SG 1 17.2 107.4 20.7 105 98 2-A
TEST LOCATION:
83 BLOCK "D" PAD #15
84 BLOCK "D" PAD #16
85 BLOCK "D" PAD #15
86 ALLEY D-1 STA. 1+90
87 ALLEY D-1 STA. 2+00
88 BLOCK "D" PAD #9
89 BLOCK "D" PAD #11
* A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS /-R'espectfully/Sdbm/~ted
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS / / / '\
D. R EST /
~~ner
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4. CEMENT TREATED
CG01083-18