Forest Cove 2-LR 980119ALPHA TESTII~C INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR
PACIFIC UNITED DEV. CORP. DATE 01/19/98
C/O ROBERT POPE & ASSOC.
PLANO, TEXAS
FOREST COVE ESTATES OUR REPORT NO.
PROJECT PHASE i & 2 98018-8.
COPPELL, TEXAS
TEST DATA:
SOIL ID O~MU~ MAXIMUM L~B IN PLACE IN PLACE ~r~Z~T COMMENT*
MOISTURE DRY DENSITY MOISTURE DRY DENSITY COMPACTION
TEST D~E NUMBER % PcF % PcF
NO.
18 01/19 FG-3.5 2 18.5 105.6 19.4 104 98 1-A
19 01/19 FG-4.5 2 18.5 105.6 19.8 102 96 1-A
20 01/19 FG-3.5 2 18.5 105.6 19.5 103 97 1-A
21 01/19 FG-4.5 2 18.5 105.6 21.3 101 96 1-A
22 01/19 FG-3.5 2 18.5 105.6 19.2 104 98 1-A
23 01/19 FG-5.1 1 17.2 107.4 18.2 105 98 1-A
24 01/19 FG-4.0 1 17.2 107.4 17.9 106 99 1-A
TEST LOCATION:
18 BLOCK "C" PaD # 15
19 BLOCK "C" PAD #14
20 BLOCK "C" PAD #14
21 BLOCK "C" PAD # 13
22 BLOCK "C" PAD #13
23 BLOCK "C" PAD # 12
24 BLOCK "C" PAD #12
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4. CEMENT TREATED
CG01083-18
* A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS spec~~
B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS Re -~-
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS ~HAT~ INC.
D. RETEST
ALPHA TESTILY, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
(972) 620-8911
REPORT OF FIELD
COMPACTION TESTS
TESTED FOR
PACIFIC UNITED DEV. CORP.
C/O ROBERT POPE & ASSOC.
PLANO, TEXAS
DATE
01/19/98
FOREST COVE ESTATES
PR~ECT P~IASE 1 & 2 OURREPO~NO. 98018-8A
COPPELL, TEXAS
TEST DATA:
TESTNo. DATE ~ NUMBERSOILID MOI~TuREOPTIMUM% MAXlMUM LABDRYD~N~TYPcF MOIS~REINPLACE% DRYDEN~rI'y.INPLACEPCF COMPACTIoNPERCENT COMMENT*
25 01/19 FG-2.8 I 17.2 107.4 17.6 106 98 1-A
26 01/19 FG-13.( 3 13.6 113.6 14.7 112 98 1-A
27 01/19 FG-'t'i.( 3 13.6 113.6 14.3 112 99 1-A
28 01/19 FG-10.( 3 13.6 113.6 15.8 109 96 1-A
29 01/19 FG-10.5 3 13.6 113.6 15.3 109 96 1-A
30 01/19 FG-9.5 3 13.6 113.6 15.4 110 97 1-A
TEST LOCATION:
25 BLOCK "C" PAD #11
26 BLOCK "D" PAD #14
27 BLOCK "D" PAD #14
28 BLOCK "D" PAD #14
29 BLOCK "D" PAD #1
30 BLOCK "D" PAD' #1
1. FILL
2. NATURAL SUBGRADE
3. LIME STABILIZED
4. CEMENT TREATED
CG01083-18
* A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS · ~ ....~
S. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS ~Respectfully' Subm/~'
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS / P.~HHA TESTI/~, INC.
D. RETEST ~aviA~~tner