ST9902-LR131030Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID: 1770 File No: C13 -0634 Date Sampled: 10/29/2013
Report Date: 10/30/2013 Sampled By: Jones, Richard
Project: West Sandy Lake Road By Order Of:
Location: Manhole Line D Station 1 +92, Inlet Line 131 -1 Station 0 +67 Order Number: 1770
Number of
Client: City of Coppell Specimens: 4
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 153912
Material: Concrete Test Method: See Below
Spec
Age Tested
Diameter
Nbr
(date : days)
(in)
A
11/05/13:7
6.00
B
11/05/13:7
6.00
C
11/26/13:28
6.00
D
11/26/13:28
6.00
Maximum
Area Load
(in 2) (Ibs)
28.27 96,325
28.27 94,675
28.27
28.27
Type 1
Specification
Strength: 3,000 psi @ 28 days
Slump: 3 -5
Air Content: 3 -6
Date Received: 10/30/2013
Curing Method: Standard
Time Sampled: 2:10 pm
Time Batched: 1:08 pm
Temp.: Ambient: 72 °F Mix: 76 °F
TEST RESULTS
Compressive
Cure Strength
Break Type Loc (PSI)
Type 3 Lab 3,410
Type 3 Lab 3,350
Report No: 153912
Page 1 of 1
Average
Strength Tested
(PSI) By Comments
3,380
Quantity Represented: 9 cu. yds. at 9 cu. yds. placed of a 9 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or
C173, C1064 and C138. Compressive strength tests per ASTM C39.
Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy)
Crig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
Lab
Lab
�� ...1...=
.,..
R
Type 2
Type 3
Type 4
Type 5 Type 6
Slump:
4.0 Inches Transported By: LMC
Air Content:
4.4%
Source /Sampled At: Truck / Center
Mix Code:
1261
Plant: 955
Truck /Ticket No: 1374 / 64351965
Quantity Represented: 9 cu. yds. at 9 cu. yds. placed of a 9 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or
C173, C1064 and C138. Compressive strength tests per ASTM C39.
Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy)
Crig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID: 1770
File No: C13 -0634 Date Sampled: 10/23/2013
Report Date: 10/25/2013
Sampled By: Hernandez, Caleb
Project: West Sandy Lake Road
By Order Of:
Location: conc on inlet
Order Number: 1770
Client: City of Coppell
REPORT. REPORT OF CONCRETE
COMPRESSIVE STRENGTH TEST LAB NO: 153680
Test Method: See Below
TEST RESULTS Report No: 153680
Page 1 of 2
Set: 1 of 2
Material: Concrete Number of Specimens: 4
Location: Inlets on Southwest Corner of West Sandy Lake and Whispering Hills Drive Intersection; Sampled Inlets, Lateral F2A and F2A
Maximum Compressive Average
Spec Age Tested Diameter
Area Load Cure Strength Strength Tested
Nbr (date : days) (in)
(in 2) (Ibs) Break Type Loc (PSI) (PSI) By Comments
A 10/30/13: 7 6.00
28.27 91,295 Type 3 Lab 3,230 3,230
B 11/20/13:28 6.00
28.27 Lab
C 11/20/13:28 6.00
28.27 Lab
D
HOLD (see remarks) -
f
H IF` � 9" r "It M F-1 11E] L`1`
Type 1 Type 2 Type 3 Type 4 Type 5 Type 6
Specification
Strength: 3,600 psi @ 28 days
Slump: 3 -5
Slump: 3.0 Inches Transported By: LMC
Air Content: 3 -6
Air Content: 5.1 % Source /Sampled At: Truck / Center
Mix Code: 1261 Plant: 952
Date Received: 10/24/2013
Truck /Ticket No: 5023 / 62955687
Curing Method: Standard
Time Sampled: 2:54 pm
Time Batched: 2:05 pm
Temp.: Ambient: 82 °F Mix: 84 °F
Quantity Represented: 6.5 cu. yds. at 6.5 cu. yds. placed of a 6.5 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or
C173, C1064 and C138. Compressive strength tests per ASTM C39.
Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy)
Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
ALLIfiMCE
GEOTECNfIICflL
CROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID: 1770
File No: C13 -0634 Date Sampled: 10/23/2013
Report Date: 10/25/2013
Sampled By: Hernandez, Caleb
Project: West Sandy Lake Road By Order Of:
Location: conc on inlet
Order Number: 1770
Client: City of Coppell
REPORT: REPORT OF CONCRETE
COMPRESSIVE STRENGTH TEST LAB NO: 153680
Test Method: See Below
TEST RESULTS Report No: 153680
Page 2 of 2
Set: 2 of 2
Material: Concrete Number of Specimens: 4
Location: Junction Box - Line G; Sampled Station 1 +00 on North Side of West Sandy Lake Rd
Maximum Compressive Average
Spec Age Tested Diameter
Area Load Cure Strength Strength Tested
Nbr (date : days) (in)
(in 2) (Ibs) Break Type Loc (PSI) (PSI) By Comments
A 10/30/13: 7 6.00
28.27 93,940 Type 3 Lab 3,320 3,320
B 11/20/13: 28 6.00
28.27 Lab
C 11/20/13:28 6.00
28.27 Lab
D
HOLD (see remarks) -
HI-711 F-11-1 11
Type 1 Type 2 Type 3 Type 4 Type 5 Type 6
Specification
Strength: 3,600 psi @ 28 days
Slump: 3 -5
Slump: 4.75 Inches Transported By: Southern Star
Air Content: 3 -6
Air Content: 3.0% Source /Sampled At: Truck / Center
Mix Code: 1083 Plant: 111
Date Received: 10/24/2013
Truck /Ticket No: 4035 / 1313139
Curing Method: Standard
Time Sampled: 4:15 pm
Time Batched: 3:31 pm
Temp.: Ambient: 82 °F Mix: 82 °F
Quantity Represented: 10 cu. yds. at 10 cu. yds. placed of a 10 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or
C173, C1064 and C138. Compressive strength tests per ASTM C39.
Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy)
Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.