Loading...
ST9902-LR131004f1LLlf�'10E C� OTECHf11C RL C�iOl1P Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C13 -0634 Curing Method: Standard Date Sampled: 09/27/2013 Report Date: 10/04/2013 Previously Reported: 09/30/2013 Time Batched: 8:47 am Sampled By: Roberts, Duce Project: West Sandy Lake Road By Order Of: Location: Backwall at Abutment #4; Also South Wing Wall at Abutment #4 Order Number: 1770 Number of Client: City of Coppell Specimens: 5 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 152086 Material: Concrete Test Method: See Below TEST RESULTS Report No: 152086 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 09/30/13: 3 6.00 28.27 73,990 Type 2 Lab 2,620 2,620 B 10/04/13: 7 6.00 28.27 88,915 Type 3 Lab 3,140 C 10/04/13: 7 6.00 28.27 91,460 Type 3 Lab 3,230 3,190 D 10/25/13:28 6.00 28.27 Lab E 10/25/13:28 6.00 28.277 Lab �i _�. _ Its.,_. ~. I.. Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 3,600 psi @ 28 days Slump: 3 -5 Air Content: 3 -6 Date Received: 09/28/2013 Curing Method: Standard Time Sampled: 9:45 am Time Batched: 8:47 am Temp.: Ambient: 82 °F Mix: 84 °F Slump: 3.5 Inches Air Content: 4.8% Mix Code: 5409 Transported By: LMC Source /Sampled At: Truck / Center Plant: 952 Truck /Ticket No: 1407 / 62954585 Quantity Represented: 8 cu. yds. at 8 cu. yds. placed of a 8 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. r i�'• 'iu�, Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C13 -0634 Date Sampled: 09/06/2013 Report Date: 10/04/2013 Previously Reported: 09/10/2013 Sampled By: Roberts, Duce Project: West Sandy Lake Road By Order Of: Location: Line F 9x9 Junction Box at Station 10 +94.36 Order Number: 1770 Number of Client: City of Coppell Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 151199 -1 Material: Concrete Test Method: See Below TEST RESULTS Report No: Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 09/13/13: 7 6.00 28.27 119,575 Type 3 Lab 4,230 B 09/13/13: 7 6.00 28.27 123,590 Type 3 Lab 4,370 4,300 C 10/04/13: 28 6.00 28.27 141,775 Type 3 Lab 5,010 D 10/04/13: 28 6.00 28.27 145,240 Type 3 Lab 5,140 5,080 F11<11,F] F[q R"'611 R, F111- 1� Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 3,000 psi @ 28 days Slump: Air Content: Date Received: 09/07/2013 Curing Method: Standard Time Sampled: 3:20 pm Time Batched: 2:09 pm Temp.: Ambient: 97 °F Mix: 88 °F CONFORMS Slump: 2.0 Inches Transported By: LMC Air Content: 5.5% Source /Sampled At: Truck / Center Mix Code: 1261 Plant: 955 Truck /Ticket No: 8096 / 64349130 Quantity Represented: 9 cu. yds. at 9 cu. yds. placed of a 9 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES. NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. RLLEngliCE GeorEcrirncAL GROUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C13 -0634 Date Sampled: 09/05/2013 Report Date: 10/04/2013 Previously Reported: 09/13/2013 Sampled By: Roberts, Duce Project: West Sandy Lake Road By Order Of: Location: Various Locations Order Number: 1770 Client: City of Coppell REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 151120 -1 Test Method: See Below TEST RESULTS Report No: 151120 -1 Page 1 of 2 Set: 1 of 2 Material: Concrete Number of Specimens: 6 Location: Second Truck, Abut #4 36in Pier #4H Maximum Compressive Average Spec Age Tested Diameter Area Load 9:45 am Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 09/09/13: 4 6.00 28.27 102,950 Type 3 Lab 3,640 B 09/09/13: 4 6.00 28.27 102,905 Type 2 Lab 3,640 3,640 C 09/12/13: 7 6.00 28.27 117,990 Type 3 Lab 4,170 D 09/12/13: 7 6.00 28.27 116,665 Type 3 Lab 4,130 4,150 E 10/03/13: 28 6.00 28.27 159,395 Type 3 Lab 5,640 F 10/03/13: 28 6.00 28.27 158,865 Type 4 Lab 5,620 5,630 R I l t �._ — _..__i Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 3,600 psi @ 28 days Slump: 3.5 -7.5 Air Content: Date Received: 09/06/2013 Curing Method: Standard Time Sampled: 9:45 am Time Batched: 8:26 am Temp.: Ambient: 85 °F Mix: 80 °F CONFORMS Slump: 7.0 Inches Transported By: LMC Air Content: 1.2% Source /Sampled At: Truck / Center Mix Code: 5506 Plant: 952 Truck /Ticket No: 7069 / 62953368 Quantity Represented: 7 cu. yds. at 15 cu. yds. placed of a 15 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. 4 riu.��ncE GEOTECFiI`IICRL C�tOUP Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C13 -0634 Date Sampled: 09/05/2013 Report Date: 10/04/2013 Previously Reported: 09/13/2013 Sampled By: Roberts, Duce Project: West Sandy Lake Road By Order Of: Location: Various Locations Order Number: 1770 Client: City of Coppell REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 151120 -1 Test Method: See Below TEST RESULTS Report No: 151120 -1 Page 2 of 2 Set: 2 of 2 Material: Concrete Location: First pour, Columns 2D, 2E and 2F Spec Age Tested Diameter Nbr (date : days) (in) A 09/09/13:4 6.00 B 09/09/13:4 6.00 C 09/12/13:7 6.00 D 09/12/13:7 6.00 E 10/03/13:28 6.00 F 10/03/13:28 6.00 Number of Specimens: 6 Maximum 09/06/2013 Curing Method: Compressive Average Area Load Time Batched: Cure Strength Strength Tested (W) (lbs) Break Type Loc (PSI) (PSI) By Comments 28.27 83,065 Type 3 Lab 2,940 28.27 81,930 Type 3 Lab 2,900 2,920 28.27 92,880 Type 3 Lab 3,280 28.27 93,800 Type 3 Lab 3,320 3,300 28.27 127,495 Type 3 Lab 4,510 28.27 125,230 Type 4 Lab 4,430 4,470 t F;]< , F__-] [TI 17, 1 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 3,600 psi @ 28 days Slump: Air Content: Date Received: 09/06/2013 Curing Method: Standard Time Sampled: 1:45 pm Time Batched: 12:22 pm Temp.: Ambient: 95 °F Mix: 82 °F CONFORMS Slump: 7.0 Inches Transported By: LMC Air Content: 4.5% Source /Sampled At: Truck / Center Mix Code: 5409 Plant: 952 Truck /Ticket No: 1417 / 62953397 Quantity Represented: 9 cu. yds. at 9 cu. yds. placed of a 9 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES. NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.