Loading...
ST9902-LR130925MLUnNCE c�o-rEcHnic�L C� UP i Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C13 -0634 08/29/2013 Curing Method: Date Sampled: 08/28/2013 Report Date: 09/26/2013 Previously Reported: 08/30/2013 3:30 am Time Batched: Sampled By: Roberts, Duce Project: West Sandy Lake Road 95 °F Mix: 92 °F By Order Of: Location: 36" Pier and Abutment #2, Pier #2E 2nd truck Order Number: 1770 Number of Client: City of Coppell Specimens: 4 REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 150698 -1 Material: Concrete Test Method: See Below TEST RESULTS Report No: 150698 -1 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 09/04/13: 7 6.00 28.27 91,705 Type 3 Lab 3,240 B 09/04/13: 7 6.00 28.27 89,235 Type 3 Lab 3,160 3,200 C 09/25/13: 28 6.00 28.27 123,320 Type 3 Lab 4,360 D 09/25/13: 28 6.00 28.27 120,520 Type 4 Lab 4,260 4,310 R11F1/_1 RM M F-1 FIFI 11 Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 3,600 psi @ 28 days Slump: 5.5 -7.5 Air Content: Date Received: 08/29/2013 Curing Method: Standard Time Sampled: 3:30 am Time Batched: 2:41 am Temp.: Ambient: 95 °F Mix: 92 °F CONFORMS Slump: 6.5 Inches Transported By: LMC Air Content: 1.1 % Source /Sampled At: Truck / Center Mix Code: 5506 Plant: 950 Truck /Ticket No: 3010 / 62467825 Quantity Represented: 5 cu. yds. at 11 cu. yds. placed of a 11 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION. prrul�luu i� �I i � aul Consulting Engineering * Geotechnical Engineering * Construction Materials 3228 Halifax Street, Suite A, Dallas, Texas 75247 Phone: (972) 444 -8889 Fax: (972) 444 -8893 Acct ID: 1770 File No: C13 -0634 Date Sampled: 09/19/2013 Report Date: 09/20/2013 Sampled By: Godwin, Jonathan Project: West Sandy Lake Road By Order Of: Location: South bridge column, Sampled: West side of south bridge column Order Number: 1770 Number of Client: City of Coppell Specimens: 4 REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST LAB NO: 151741 Material: Concrete Test Method: See Below TEST RESULTS Report No: 151741 Page 1 of 1 Maximum Compressive Average Spec Age Tested Diameter Area Load Cure Strength Strength Tested Nbr (date : days) (in) (in 2) (Ibs) Break Type Loc (PSI) (PSI) By Comments A 09/25/13: 6 6.00 28.27 83,330 Type 3 Lab 2,950 2,950 B 09/26/13:7 6.00 28.27 Lab C 10/17/13:28 6.00 28.27 Lab D 10/17/13:28 6.00 28.27 Lab I E-1�1 E] LIL Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Specification Strength: 3,600 psi @ 28 days Slump: 3 -5 Air Content: 3 -6 Date Received: 09/20/2013 Curing Method: Standard Time Sampled: 2:10 pm Time Batched: 1:21 pm Temp.: Ambient: 87 °F Mix: 85 °F Slump: 5.0 Inches Air Content: 5.5% Mix Code: 5409 Transported By: LMC Source /Sampled At: Truck / Center Plant: 952 Truck /Ticket No: 7017 / 62954261 Quantity Represented: 8 cu. yds. at 17 cu. yds. placed of a 17 cu. yd. total placement Remarks: Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or C173, C1064 and C138. Compressive strength tests per ASTM C39. Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy) Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E. Respectfully Submitted, Alliance Geotechnical Group Perry C. Kakara, CME Department Manager THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENT AND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.