ST9902-LR130923ALLIfitYCE
GEOTLCtif11CHL
Gi{7UP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID: 1770 File No: C13 -0634
Date Sampled: 08/26/2013
Report Date: 09/24/2013 Previously Reported: 08/29/2013
Sampled By: Roberts, Duce
Project: West Sandy Lake Road
By Order Of:
Location: Abutment 1, 36" Pier #1J
Order Number: 1770
Number of
Client: City of Coppell
Specimens: 4
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH
TEST
LAB NO: 150690
Material: Concrete
Test Method: See Below
TEST RESULTS
Report No: 150690
Page 1 of 1
Maximum
Compressive
Average
Spec Age Tested Diameter Area Load Cure
Strength
Strength Tested
Nbr (date : days) (in) (in 2) (Ibs) Break Type
Loc
(PSI)
(PSI) By Comments
A 09/02/13 : 7 6.00 28.27 136,565 Type 3
Lab
4,830
B 09/02/13: 7 6.00 28.27 143,000 Type 3
Lab
5,060
4,940
C 09/23/13 : 28 6.00 28.27 181,060 Type 3
Lab
6,400
D 09/23/13: 28 6.00 28.27 180,8860 Type 3
Lab
6,400
6,400
RE!", Rp [U
F-1
FIF] 1�
Type 1 Type 2 Type 3
Type 4
Type 5
Type 6
Specification
Strength: 3,600 psi @ 28 days
Slump: 5.5 -7.5
Air Content:
Date Received: 08/27/2013
Curing Method: Standard
Time Sampled: 3:15 pm
Time Batched: 2:35 pm
Temp.: Ambient: 95 °F Mix: 90 °F
CONFORMS
Slump: 5.5 Inches Transported By: LMC
Air Content: 1.0% Source /Sampled At: Truck / Center
Mix Code: 5506 Plant: 955
Truck /Ticket No: 9114 / 64348443
Quantity Represented: 9 cu. yds. at 18 cu. yds. placed of a 18 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or
C173, C1064 and C138. Compressive strength tests per ASTM C39.
Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy)
Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
Respectfully Submitted,
Alliance Geotechniical Group
4(_
Perry C. Kakara, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
0 IYCE
IT IMICFiL
OUF'
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID: 1770 File No: C13 -0634
Date Sampled: 09/13/2013
Report Date: 09/24/2013 Previously Reported: 09/16/2013
Sampled By: Armas, Brandon
Project: West Sandy Lake Road
By Order Of:
Location: Bent #2, Sampled: Bent #2 above Column 2E
Order Number: 1770
Number of
Client: City of Coppell
Specimens: 5
REPORT: REPORT OF CONCRETE COMPRESSIVE STRENGTH
TEST LAB NO: 151320
Material: Concrete
Test Method: See Below
TEST RESULTS Report No: 151320
Page 1 of 1
Maximum Compressive Average
Spec Age Tested Diameter Area Load Cure
Strength Strength Tested
Nbr (date : days) (in) (in 2) (Ibs) Break Type Loc
(PSI) (PSI) By Comments
A 09/16/13: 3 6.00 28.27 78,855 Type 3 Lab
2,790 2,790
B 09/20/13 : 7 6.00 28.27 95,695 Type 3 Lab
3,380 3,380
C 10/11/13:28 6.00 28.27 Lab
D 10/11/13:28 6.00 28.27 Lab
E
HOLD (see remarks) -
RE I 1
RM
i
I.� J
Type 1 Type 2 Type 3 Type 4
Type 5 Type 6
Specification
Strength: 3,600 psi @ 28 days
Slump: 3 -5 Slump: 5.0 Inches
Transported By: LMC
Air Content: 3 -6 Air Content: 4.0%
Source /Sampled At: Truck / Center
Mix Code: 5409
Plant: 955
Date Received: 09/14/2013
Truck /Ticket No: 1424 / 64349617
Curing Method: Standard
Time Sampled: 2:00 pm
Time Batched: 12:56 pm
Temp.: Ambient: 96 °F Mix: 93 °F
Quantity Represented: 9 cu. yds. at 9 cu. yds. placed of a 17 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or
C173, C1064 and C138. Compressive strength tests per ASTM C39.
Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy)
Ong: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.
ALLIfitYCE
GEOTECMICRL
CROUP
Consulting Engineering * Geotechnical Engineering * Construction Materials
3228 Halifax Street, Suite A, Dallas, Texas 75247
Phone: (972) 444 -8889 Fax: (972) 444 -8893
Acct ID: 1770 File No: C13 -0634
08/27/2013
Curing Method:
Date Sampled: 08/23/2013
Report Date: 09/24/2013 Previously Reported: 08/27/2013
1:15 pm
Time Batched:
Sampled By: Roberts, Duce
Project: West Sandy Lake Road
93 °F Mix: 90 °F
By Order Of:
Location: 36 inch Pier at Abutment 1, Pier #1G - 2nd truck
Order Number: 1770
Number of
Client: City of Coppell
Specimens: 4
REPORT. REPORT OF CONCRETE COMPRESSIVE STRENGTH TEST
LAB NO: 150221
Material: Concrete
Test Method: See Below
TEST RESULTS
Report No: 150221
Page 1 of 1
Maximum
Compressive
Average
Spec Age Tested Diameter Area Load
Cure
Strength
Strength Tested
Nbr (date : days) (in) (in 2) (Ibs) Break Type
Loc
(PSI)
(PSI) By Comments
A 08/30/13 : 7 6.00 28.27 97,620 Type 3
Lab
3,450
B 08/30/13: 7 6.00 28.27 103,435 Type 3
Lab
3,660
3,560
C 09/20/13: 28 6.00 28.27 143,205 Type 3
Lab
5,060
D 09/20/13: 28 6.00 28.27 143,860 Type 3
Lab
5,090
5,080
BE] RR [U
`
[1] 1�
Type 1 Type 2 Type 3
Type 4
Type 5
Type 6
Specification
Strength: 3,600 psi @ 28 days
Slump: 5.5 -7.5
Air Content:
Date Received:
08/27/2013
Curing Method:
Standard
Time Sampled:
1:15 pm
Time Batched:
12:25 pm
Temp.: Ambient:
93 °F Mix: 90 °F
CONFORMS
Slump: 7.0 Inches Transported By: LMC
Air Content: 1.0% Source /Sampled At: Truck / Center
Mix Code: 5506 Plant: 952
Truck /Ticket No: 9141 / 62952714
Quantity Represented: 14 cu. yds. at 14 cu. yds. placed of a 14 cu. yd. total placement
Remarks:
Test Method (As Applicable): Unless noted, concrete was sampled and tested in accordance with ASTM C31, C172, C143, C231 or
C173, C1064 and C138. Compressive strength tests per ASTM C39.
Client: City of Coppell Attn: Mr. Rick O'Dell (1 -cc copy)
Orig: City of Coppell (Coppell, TX) Attn: Mr. Keith Marvin, P.E.
Respectfully Submitted,
Alliance Geotechnical Group
Perry C. Kakara, CME Department Manager
THIS REPORT APPLIES ONLY TO THE STANDARDS OR PROCEDURES INDICATED AND TO THE SAMPLE(S) TESTED AND /OR OBSERVED AND ARE NOT NECESSARILY INDICATIVE OF
THE QUALITIES OF APPARENTLY IDENTICAL OR SIMILAR PRODUCTS OR PROCEDURES, NOR DO THEY REPRESENT AN ONGOING QUALITY ASSURANCE PROGRAM UNLESS SO
NOTED. THESE REPORTS ARE FOR THE EXCLUSIVE USE OF THE ADDRESSED CLIENTAND ARE NOT TO BE REPRODUCED WITHOUT WRITTEN PERMISSION.