Loading...
Freeport NIP(3)-LR 951031 (3)reed engineering GEOTECHNICAL CONSULTANTS October 31, 1995 Project No. 2B17.2 Report No. 8 M.E.P.C. American Properties, Inc. 15303 Dallas Parkway, Suite 100, LB-10 Dallas, Texas 75248 ATTN: Mr. Rob Ahmuty Re: Construction Materials Testing Craftmade Coppell, Texas Gentlemen: Submitted here are the results of testing and observation of construction materials at the referenced project. This report addresses activities for the period of October 19 through 26, 1995. "Select" fill was delivered to the site on October 19, 1995. A sample of the fill was obtained and tested for Atterberg Limits [Plasticity Ihdex (PI)]. The "select" fill met project specifications. An optimum-moisture maximum density curve (Standard Proctor Curve) was therefore developed. The results of the Atterberg Limit test are shown on the moisture-density curve, Plate 1 (Curve No. 5) attached. During the of October 19 through 27, 1995, total of 13 field density tests were taken on panel leave-out backfill and paving subgrade. Test results are shown on Plate 2. Where tested, materials were found to be in compliance with project specifications. 2424 STUTZ DRIVE · SUITE400 · DALLAS, TEXAS75235 · 214/350-5600 · (FAX) 214/350-0019 M.E.P.C. American Properties, Inc. Project No. 2317.2/Report No. 8 October 31, 1995 Page 2 Additional reports will be submitted as work progresses. any questions, do not hesitate to call. If you have Sincerely, Ronald F. Reed, P.E. BES/RFR/msm copies submitted: (1) M.E.P.C. American Properties, Inc./ Mr. Rob Ahmuty (1) Gromatzky Dupree and Associates/ Mr. Scott McCrary (1) McFadden & Miller/Mr. Jon Jacobson (1) Eckland Consultants/Mr. Jerry Holstrom (1) City of Coppell/Mr. Lee Stone ~1) City of Coppell/Mr. Larry Davis ~ mnginaeH .ng 117 115 113 .111 8 10 12 14 16 Moisture Content (%) Standard Proctor Compaction Test No. 5 25. blows per each of 3 layers, with5.5 pound hammer and 12 inch drop using 4 inch diameter mold Test performed on minus #4 'Si eve size material Boring No. -- Location Craftmade Depth - Sample No. __ Classification Coppell, Texas Yellowish-brown clayey sand "select" fill Liquid Limit 24 % Maximum Unit Plastic Limit 12 % Dry Weight 116.7 pcf Plasticity Index 12 Optimum Moisture Content 11.9 % OPTIMUM MOISTURE DENSITY CURVE GEOTECHNICAL CONSULTANTS , DI hTr' 1 reed en. gineering CRAFTMADE COPPELL, TEXAS REPORT NO. 8 Test Date No. 10-19-95 312 313 10-20-95 314 315 10-21-95 316 317 318 319 320 10-26-95 321 322 10-27-95 32B 324 Field Density Tests Location Depth Com- Below Unit pac- Final Dry Moisture tion S.G. Weight Content Curve Level (feet) (pcf) (%) No. (%) I'S, 140'W(1) 1'S, 180'W(1) l'S, 10'E (2) i'S, 50'E(2) 40'N, 40'W(2,3) 0 40'N, 90'E(2,3) 0 45'N, 300'E(2,3) 0 320'S, 2'E(2) 2 360'S, 2'E(2) 1 550'S, 2'W(1) 3 550'S, 2'W(1) 0 60'S, 2'E(2) 0 70'S, 0.0 1.5 1.0 0 0 0 0 0 5 0 0 8 0 2'E(2) 0.0 115 2 114 7 114 7 113 3 92 5 92 4 90 9 110 9 110 9 107 0 106 7 111.9 114.5 12.0 5 10.4 5 12.3 5 11.0 5 28.6 1 26.5 1 27.8 1 13.6 5 12.4 5 17.7 2 16.1 2 12.8 5 13.1 5 98.7 98.3 98.3 97.1 99.7 99.6 98 0 95 0 95 0 98 7 98 4 95 9 98 1 Footnotes: (1) (1) (2) Location referenced from N.E. building corner. Location referenced from N.W. building corner. Test taken on paving subgrade. GEOTECHNICAL CONSULTANTS - PLATE 2