Loading...
Westhaven Phase 2B-150825LMC Date: 08/25/2015 Client: TEXAS INLETS INC Attention: Project: WESTHAVEN PHASE 2B Location: COPPELL, TEXAS Lattimore Materials Corp. 15900 DOOLEY ROAD ADDISON TX 75001 (972) 221-4646 (main) (972) 221-9647 (fax) Usage Mix Number f 'c wlc+p Slump Air INLETS, MANHOLES, HEADWALLS 1701. 4000 0.45 3.00 - 5.00" 3.0-6.0% LMC has no knowledge or authority regarding where this mixture is to be placed, therefore it is the direct responsibility of the Purchaser, the design architect or design engineer, and or contractor to insure that the above designed mixture parameters for compressive strength, mixture proportions or ratios, and other required performance parameters are appropriate for the anticipated environmental, durability, or usage conditions in ACI 318 Chapter 4 and/or the relevant local building codes. LMC warrants the supplied ready -mix concrete mixture designs which LMC guarantees will achieve the specified compressive strength, or other performance properties of the concrete stated in the Contract Documents, as were made available at the time of quotation, when tested and evaluated in accordance with ASTM C172-99, ASTM C31/C31 M -03a (including proper initial curing as per Section 10.1.2), ASTM C39/C39M-01, ASTM C94/C94M-07, or other standard test methods indicated in the Contract Documents that were necessary to verify the additional performance properties of the concrete, and when the recommended procedures for placement and curing of the in-place concrete, or those specifically outlined in ACI 305R-99 and ACI 306R-88 are followed, if and when necessary. In accordance with ASTM C94/C94M-07 Section 4.6, Lattimore Materials Corp shall receive all copies of testing reports, and they should be forwarded to our Quality Control Department (mixdesign@aggregate-us.com) as soon as available. Failure to forward reports in a timely fashion can delay response time in dealing with concrete concerns as well as future project submittals. This mix design submittal, price quote, or material specific information (aggregate properties, grading, material composition, or other information regarding materials manufactured by Lattimore Materials Corp) is proprietary and confidential and not to be shared or transmitted in any form to any person or organization that is not expressly authorized in writing by a designated official of Lattimore Materials Corp. Any unauthorized person or entity in possession of this information will be prosecuted to the fullest extent of the law. Material certifications for concrete constituents are representative of current material sources. If, in the event of limited material availability, substitution of a similar performing material may be required. Such materials will meet the appropriate ASTM requirements as stated in this package. In order to maintain the required mix volume (yield), LMC reserves the right to adjust absolute weight of aggregates to accommodate specific gravity changes. LMC mix designs requiring air -entrainment are produced in accordance wiht ASTM C 94 Section 8.2, which allows for a tolerance of 1.5% above and below the target, and is stated as follows: ASTM C94IC94M -13a 8.2 The air content of air -entrained concrete when sampled from the transportation unit at the point of discharge shall be within a tolerance of +/-1.5 of the specified value. 1992 - 2015 Digital Site Systems, Inc. page 1 Quadrel iService SM LMC Date: Client: Project: Concrete Mix Design 08/25/2015 TEXAS INLETS INC WESTHAVEN PHASE 2B COPPELL, TEXAS 1.0 Cubic Yard by Weight - SSD Mix Number: 1701. Strength @ 28 Days: 4000 psi Usage: INLETS, MANHOLES, HEADWALLS Lattimore Materials Corp. 15900 DOOLEY ROAD ADDISON TY. 75001 (972) 221-4646 (main) (972) 221-9647 (fax) Materials: 4001 Ibs Unit Weight: SSD Weights Cement ASTM C-150 Type 1/11 564 lbs Coarse Aggregate ASTM C-33 1"-#4 Crushed Stone 1850 lbs Fine Aggregate ASTM C-33 Concrete Sand 1328 lbs Water ASTM C-94 Water 256 lbs Admixture ASTM C-260 Air -Entraining Admix 0.65 oz/cwt C+P Admixture ASTM C-494 Type A/D WR 4.0 oz/cwt C+P Admixture ASTM C-494 Type B/D WR 1.0 oz/cwt C+P Total Weight: 4001 Ibs Unit Weight: 148.09 pcf w/cm Ratio: 0.45 Fly Ash Replacement: 0.0% Slump: 3.00 - 5.00 inches Air Content: 3.0-6.0% Comments: The cementitious content of the mix design is stated as a minimum and Lattimore Materials Corp. reserves the right to increase cementitious content if needed. Chemical admixtures are added in accordance with the manufacturer's recommendations. Lattimore Materials Corp. reserves the right to adjust dosages or change admixtures when required. 1992 - 2015 Digital Site Systems, Inc. Page 3 Quadrel Service sm LMC Data: 8/25/2015 Mix Name: 1701. Statistical Compressive Strength History units: US PSI Strength and Strength Fit vs Maturity PSI # of Occ. Histogram for 28 Day Strength %/PSI 8500 8000 7500 7000 6500 6000 5500 5000 4500 4000 3500 r 0 10 20 30 40 50 60 8500 8000 7500 7000 6500 6000 5500 5000 4500 4000 3500 14.000.09 12.00 Date Slump Spread d Strengths Acc Age 10.00 8.00' 6.00 4.00 2.00 0.00 I � i I 0.08 0.06 0.05 0.04 0.03 0.01 0.00 � 62964584 5/16/2014 4.25 5.10 l 6110 64363543 4500 5000 5500 6000 6500 7000 7500 8000 8500 Maturity Days PSI 95016 of tests lie above cross -hatched area STRENGTH SUMMARY, Compression Either 4" x 8" Or 6" x 12" Strengths No. Of Avg Avg Avg 3 Avg 7 Avg 28 Std ACI318 Tests Slump Air Day Day Day Dev Req'd ------------------------------------------------------------------------------ 30 3.53 3.61 4930 6250 440 4600 DETAILED STRENGTH, Compression Either 4" x 8" Or 6" x 12" Batch Date Slump Spread Air Strengths Acc Age Number ------------------------------------------------------------------------------ 3 Day 7 Day 28 Day Run Avg 3 62964584 5/16/2014 4.25 5.10 5070 6110 64363543 5/22/2014 5.00 4.30 4190 6040 63688481 6/2/2014 2.50 2.00 4540 5860 6000 63690516 7/15/2014 3.50 5.30 5200 5900 5930 71001005 7/22/2014 2.50 3.30 5310 6330 6030 62492090 8/1/2014 3.50 4.80 4920 6620 6280 62815637 8/18/2014 3.75 4.50 5050 6230 6390 63692401 8/19/2014 1.00 3.00 5110 5990 6280 71004393 10/3/2014 2.75 4.10 4990 6130 6110 62499124 11/12/2014 4.00 3.30 4320 5980 6030 71005756 11/12/2014 3.75 4.50 5270 6330 6150 63164624 11/17/2014 4.00 3.90 4860 5970 6100 63696592 11/17/2014 4.50 4.20 4880 6310 6200 71006609 12/3/2014 8.00 2.00 3720 5810 6030 62502067 1/14/2015 5.00 2.30 4590 6520 6210 63698897 1/14/2015 1.25 3.00 4980 6150 6160 63699957 1/30/2015 1.50 2.20 4960 6170 6280 62821839 2/4/2015 3.50 4.60 5280 6630 6310 63700189 2/4/2015 2.00 2.60 5610 6890 6560 62821933 2/5/2015 3.00 3.40 5580 8130 7210 1992 - 2015 Digital Site Systems, Inc. page 4 Quadrel iService SM DETAILED STRENGTH, Compression Batch Date Slump Spread Air Number 63089104 2/10/2015 4.00 63170099 2/12/2015 3.75 63089504 3/12/2015 4.00 63172188 4/3/2015 3.50 63172530 4/8/2015 3.00 63173005 4/15/2015 6.25 62824469 4/30/2015 3.00 63289642 5/28/2015 2.25 63704093 6/16/2015 3.00 62826576 6/30/2015 4.00 2.60 4.20 3.70 3.90 4.20 3.00 3.00 3.50 4.30 Either 4" x 8" Or 6" x 12" Strengths Acc Age 3 Day 7 Day ---------------------------------- 28 Day Run Avg 3 5450 6020 7010 4230 6350 6840 5170 6480 6290 4960 6100 6310 5070 6000 6190 3880 5940 6010 5160 6080 6000 4950 5810 5940 5600 6800 6230 4930 5990 6200 1992 - 2015 Digital Site Systems, Inc. Page'S Quadrel iService SM I Holcim Material: Type: vCrslon Material Certification Report Portland Cement Test Period: 01 -Mar -2015 1-11 To: 30 -Mar -2015 = Cefic*jai� . This Holcim cement meets the specifications of ASTM C150 for Type WI cement General Infomiatian 1, ' Supplier:nUInc. Source Location: on: Midlothian Plant Address: 1800 ( Lane- - 1800 Dove Lane Midlothian, TX, 76065 Midlothian, TX, 76065 Telephone: (972) 923-5800 Contact: Javier Sosa Date Issued: 13 -Apr -2015 The foilov ing information is based on average test data during the test period. The data is typical of cement shipped by Holcimindividual shipments may vary. Tests'D to orl`AST11ll tarsi iald I egillremen s , Chemical Physical Item Limit"' Result Item Limle Result I % 19.7 Air Content (%) 12 max 9 A603 (%) 6.0 max 4.7 Braine Fineness (m2/kg) 260 min 377 F6203 (°h) 6.0 max 3.3 coo (%) - 642 M90 (°Yo) 6.0 max 0.9 Autoclave Expansion (%) (C151) 0.80 max 0.06 S03 (%) 3.0 maxa 3.5 Compressive Strength MPa (psi): Loss on Ignition. (%) 3.0 max 2.3 Insoluble Residue (%} 0.75 max 0.49 3 days 12.0 (1740) min 27.6 (4000) CO2 (%)° - 1.1 7 days 19.0 (2760) min 33.8 (4900) Limestone (/o) 5.0 max 3.2 CaCO3 In Limestone (%) 70 min 79 Initial Vicat (minutes) 45-375 104 Inorganic Processing Addition 5.0 max 0.0 Potential Phase Compositlone: Mortar Bar Expansion (01038) - 0.010 C3S (%) - 63 CzS (%) - 8 C3A (%) 8 max 7 CAF (%) - 10 C3S + 4.75C3A 96.3 LL ` bests Data a AS M'= ho at Regairemlenfs n Tr � rr: r Chemical Physical Item Limit" Result° Item Limle Result Equivalent Alkalies (%) - 0.60 —^.-�I,��1�.f ,y Y.h� i i1� .,}`r d,��uS ya' , '�I L r d � l..' t 4 - L.n� i ,ti•= -, � t. " Dashes in the limit / result columns mean Not Applicable. ift ° It is permissible to exceed the specification limit provided that ASTM C1038 Mortar Bar Expansion does not exceed 0.020 % at 14 days. c Ad)usled per Annex A1.6 of ASTM C150 and AASHTO M85. ti ° Maximum total alkali, based on a 95% confidence interval level per TxDOT DMS 4600. This data may have been reported an previous mill certificates. sale of Tome countyot f 0 Q�,�,(�) � LINDA K. LANIER t1Nom end a bed before 1119 tlYs ]� J' St PublicNotioy °� - �pJ-`�� a eXas Comm, E>�ires 2-20-2017 Pebld A(iCWlotlal Data t i i, Inorganic Processing Addition Data Base Cement Phase Composition w Item Resuir Item Result Type - Cas NO 65 Amount (%) _ (yo) Sit (%) _ 9 AIz03 (°A) _ CaA (%) 7 C4AF (%) 10 Fe203 (%) _ CaO (%) _ S03(%) _ By �. — , Quality Manager Javier Sosa man saw HMDEL.BEROCEMENTGtoup Hanson Aggregates Southwest Region Technical Services Lab 1000 N. MacArthur Blvd. Grand Prairie, TX 75050 Tel. 972-260-3646 Fax. 972-260-3655 www.hansonpic.com MATERIALS EVALUATION Coarse Aggregates Source: Hanson L? Bridgeport (Perch -Hill) Plant Technical Services #777 Type: ASTM #57 (1" - #4) Crushed Lime Stone Report: 2015-777 Lab NO: TS -Weekly -15 Date: 07-24-15 Date: Received: 07-01-I5 ASTM METHOD TEST DESCRIPTION TEST RESULTS ASTM C-33 Specification C-136 2'' Sieve 100 % Passing -------- C-136 1-l%2" Sieve I00 °,o Passin_ 100 C-136 1" Sieve 96 % Passing 95-100 C-136 ;i4" Sieve 78 % Passing ------- C-136 UT' Sieve 49 % Passing 25-60 C-136 3J8" Sieve 36 % Passing ------- C-136 #4 Sieve 6 4o Passing 0-10 C-136 48 Sieve 2 °io Passing 0-5 C-136 #16 Sieve 2 % Passing ------- C-117 Decant (- #200 Sieve Washed) C-127 Relative Bulk Specific Gravity., SSD C-127 Relative Bulk Specific Gravity. Dry C-127 Absorption, C-29 Unit Weight (Dry Rodded), C-29 Unit Weight (Dry Loose), C-29 Voids Content (Dry Rodded), C-131 L.A. Abrasion. C-1260 Potential Alkali Reactivity of Aggregates, C-88 Soundness by Sodium 26.8 Sulfate (5 cycles). ....... I...... C-88 Soundness by Magnesium Ob Exp. Sulfate (5 cycles), ............... C-123 Light Weight Pieces. C-142 Clay Lumps and Friable Particles, C-25 Calcium Carbonate EQV. C-25 .Acid Insoluble Residue. Note: - Hanson Product Code TX -130 0.90 % Passing 1.5% Max. 2.663 2.632 0.9 % 104.4 Lbs/Cu.Ft. 94.1 Lbs.!Cu.Ft. 38.3 26.8 °10 Loss 50% Max. 0.03 Ob Exp. 0.1 % Max 2.30 °'o Loss 12% Max. 3.90 % Loss 18% Max. 0.01 °0 0.5% Max. 0.01 ° 1 3.0% Max. 9,614�0 .0 4 .0 'G c A itSr1 r�i 1�'�+t�R Y Varian Babakhanian. P.E. � � d fi d Technical Services Lab Manager Our letters, anahsis and reports are for the exclusive use of the client to whom the} are addressed. appl} oniv to the sample tested and or inspected and are not necessarily indicative of the qualities of apparentic identical or similar products. This report shall not be reproduced except in hall and with the written approtial of HANSOM PLC. LMC yrs" -rq '.,`77"�,_ Gradation Ana ASTM C29, i Date Sampled: 22 -Jun -2015 Date ran: 24 -Jun -2015 Total dry wt: 708.4 grams Lattimore Materials Corp. 15900 Dooley Road Addison, Texas 75001 972-221-4646 (main) 972-221-9647 (fax) www.laftimorematerials.com C117, C128 & D75 Sample: Blend Spec Sand Source: Ambrose Location: Loadout @a Radial Sieve Size (in) Wt. Ret. %o Ret. % Pass % Passing ASTM % Retained TxDOT C33 Limits 421 3/8" 0.375 0.0 0.0% 100.000 100% 0% #4 0.188 13.7 1.9% 98.1% --95-0/0- 1- 00% 0%-5% #8 0.094 129.3 18.3% 81.7% 80%-100% #16 0.047 204.6 28.9% 71.1% 50%-85% —0%-20% 15%-50% #30 0.023 281.9 39.8% 60.2% 25%,-60% 35% - 75% #50 0.012 566.4 80.0% 20.0% 5%-30% 65%-90% #100 0.006 667.2 94.2% 5.8% 1 0%-100 90%-100% #200 1 0.003 705.1 99.5% 0.5% 0% - 3% 97%-100% PAN S.E.. 97 Fineness Mod.: 2.63 Specific Gravity: 2.61 Dry Loose Unit Wt: 93.62 ib/ft3 Dry Rodded Unit Wt: 111.06 Ib/ft3 Absorbtion: 1.03% +o: •� BRANDI ANN HOWELL Notary public, Siate of Texas MY Commission Expires '��"�.•� Februar7 Y 5, 2016 X2 1 Product Data Sheet Edition 09.25.2009 Identification no. 147-540 Sika Air Sika° Air Air Entraining Admixture Description Sika Air admixture is an aqueous solution of organic materials. Sika Air meets the requirements of ASTM C-260 for air entraining admixtures. Applications Advantages How to Use Sika Air is recommended for use whenever air entrained concrete is desired. Ready -mix, precast and block producers can achieve predictable and uniform entrained air contents in concrete, even where harsh lean mixes are used or fly -ash is added to the concrete. Durability: ■ Air entrainment is recognized as the most effective prevention against con- crete scaling in exposed environments. Air entrained concrete delivers par- ticular benefits in the form of increased concrete durability. This is important in colder climates where frost and freeze -thaw cycles can cause scaling and damage to the concrete surface. ■ Air entraining agents help to prevent scaling by creating microscopic air voids that water trapped in the concrete can expand into when the concrete freezes, thus preventing cracks caused by the natural expansion. Entrained air voids in the concrete will also increase durability in harsh environments where concrete is exposed to deicing salts, marine salts and sulfates. Workability and Placeability: ■ Workability and placeability are also improved by the lubricating action of the microscopic bubbles in the concrete. Concrete will flow better, and bleeding and shrinkage will be reduced because less water is needed to obtain the desired workability. Dosage rates for Sika Air will typically fall between 0.5 and 3 fl. oz. per 100 lbs. (32 -195 ml/100 kg) of cementitious to entrain between 4 and 6 percent air. Higher air contents may be obtained by increasing the dosage rate. Dosage rates will vary depending on the air content required for a particular project. Typically air contents will be specified in the range of 4 to 8 percent by volume. Other factors that may affect the amount of air entrained into the concrete including total cementitious content, type of pozzolanic materials, sand grada- tion, salt/clay in aggregates, temperature and water content. The use of fly ash, particularly high LOI fly ash, can result in a higher dosage of air entrain- ment. Sika recommends that trial mixes be performed whenever material or any other changes are made that may affect the amount of entrained air. In mixes requiring a lower or higher amount dosage rate, please contact your local regional Sika office or Sika technical service department at 1-800-933- 7452 for further information. =; Mixing Measure the required quantity per batch manually or with automatic dispenser me , equipment. Add Sika Air to mixing water or sand. Do not mix with dry cement. When Sika Air is used in combination with other admixtures, care must be k, atm taken to dispense each admixture separately into the mix. ti =s� Combination c with Other Admixtures: h «h5= Combination with other admixtures, particularly water reducers and retarders, may increase the amount of entrained air in the mix. Air contents should be checked with an air -meter after batchingand dosage adjustments made at the concrete plant. 9 1 C Packaging Sika Air is available in 55 gallon drum (208 liter), 275 gallon totes (1040 liters) Y� drums and bulk delive Storage and Shelf life Sika Air should be stored at above 40°F (50C). If frozen, thaw and agitate thoroughly to return to normal state. Shelf life when stored in dry warehouse conditions between 50°F and 80°F R x , (10°C - 27°C) is one year. Typical Data Appearance Dark Amber liquid. Specific Gravity Approx. 1.0 CAUTION: IRRITANT Contains Aqueous Solution (CAS:Mixture). May cause eye/skin/respiratory a y{ irritaton. May be harmful if swallowed. Handling and Storage Avoid direct Wear contact. personal protective equipment (chemical resistant goggles/gloves/clothing) to prevent direct contact with skin and eyes. Use only in well ventilated areas. Wash thoroughly with soap and water after use. 1 Remove contaminated clothing and launder before reuse. ! First Aid Eyes: Hold eyelids apart and flush thoroughly with water for 15 minutes. Skin: Remove contaminated clothing. Wash skin thoroughly for 15 minutes with soap and water. Inhalation: Remove person to fresh air. Ingestion: Do not '< V induce vomiting. Dilute with water. Contact physician. In all cases contact a physician immediately if symptoms persist. ' +i Safety Tested and Certified by WQA according to NSF/ANSI 61 Section 5 for s'k materials safety. } Clean Up t Use personal protective equipment (chemical resistant goggles/gloves/cloth- ing). Without direct contact, remove spilled or excess and in product place suitable sealed container. Dispose of excess product and container in accor- dance with applicable environmental regulations. KEEP CONTAINER TIGHTLY CLOSED • KEEP OUT OF REACH OF CHILDREN • NOT FOR INTERNAL CONSUMPTION • FOR INDUSTRIAL USE ONLY Al information provided by Sika Corporation CSika°) concerning Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sike's current experience and knowledge of its products when property stored, handled and applied under normal conditions in accordance with Sike's instructions. In practice, the differences in materi- als, substrates, storage and handling conditions, actual site conditions and other factors outside of Sike's control are such that Slice assumes no liability for the provision of such information, advice, recommendations or instructions related to Its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability forthe intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at www.sikacorp.com or by calling 800-933-7452. Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product's most cur- rent Technical Data Sheet, product label and Material Safety Data Sheet which are available at www.sikaconstruction com or 800.933-7452. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use. SIKA warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Technical Data Sheet if used as directed within shelf fife. User determines suitability of product for intended use and assumes all risks. Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTIBILITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. Sika Corporation Sika Canada Inc. Porno Avenue 601, Delmar Avenue Lyn .� Lyndhurst, NJ 07071 Pointe -Claire, QC H9R 4A9 x_800.933-SIKA Phone: (201) 933-BB00 Phone: (514) 697-2610 Fax: (201) 9336225 Fax: (514) 667-3087 wwwstkaconstruction.com wwwsika.ca Regional Inrorrnation and Sales Centers. For the location of your nearest Sika representative, contact your regional center. ® U.S.: North East Region: Fairless Hills, PA, Phone: (215) 295.6600 North Central Region: Marton, OH, Phone: (800) 851-1545 South East Region: Conyers, GA, Phone: (770) 760-1300 South Central Region: Mesquite, TX, Phone: (972) 289.6480 Western Region: Santa Fe Springs, CA, Phone: (562) 9033650 Canada: Ontario: Mississauga, ON, Phone: (905) 795-3177, Alberta: Edmonton, AB, Phone: (780) 486.6111 Quality Certlllmdon Numbers: Lyndhurst FM 69711 (ISO 9000), FM 70421 (QS 9000), Martm: FM 69715, Kansan City: FM 69107, Santa Fe Spdngc FM 694M Sika is a registered trademark Made in USA Printed in USA. Product Data Sheet Edition 10.2005 Identification no. 161 Plastocrete 161 Plastocrete®161 Water Reducing Admixture Description Plastocrete 161 is a lignin polymer -type water -reducing admixture. Plastocrete 161 meets the requirements of ASTM C-494 Types A, B and D. Applications Plastocrete 161 is recommended for use in all applications where high quality concrete with superior workability is required. Advantages Plastocrete 161 water reducing admixture provides an economical and highly effective means of reducing the amount of mixing water required to produce concrete of a certain slump by acting as a dispersant for the cement particles in the mix. Through this dispersing action more of the surface area of the cement particles is available for early hydration. The more cement particles hydrated by contact with the mixing water, the greater the compressive strength of the concrete. Plastocrete 161 is formulated as a Type A water reducer to allow up to 10% water reduction and maximize the benefits of increased hydration in both the hardened and plastic states. ■ Reduced water content required to achieve desired slump, increases compressive and flexural strengths and allows the use of more economi- cal mixes. ■ Improved paste quality makes concrete easier to pump and finish. ■ Consistent normal setting times throughout the recommended dosage. ■ Lower water cement ratios provide decreased permeability and increased durability. ■ Plastocrete 161 does not contain intentionally added chlorides and will not initiate nor promote the corrosion of steel in the concrete. How to Use Dosage Dosage rates will vary depending on the material used, ambient conditions and the requirements of a specific project. For general concreting applications, Sika recommends a dosage rate between 2-4 fl.oz./100 lbs. (130-260 ml/100 kg) of cementitious materials for normal setting characteristics. Dosage rates of 4-6 fl.oz./100 lbs. (260-390 ml/100 kg) of cementitious materials are recommended for applications where higher water reduction is needed as well as extended workability and prolonged setting times. Dosage rates outside the recommended range may be used where specialized materials such as microsilica are specified, extreme ambient conditions are encountered or unusual project conditions require special con- sideration. In this case please contact your local regional Sika office or Sika ® technical service department at 1-800-933-7452 for further information. Packaging Plastiment ES is available in 55 gallon drum (208 liter), 275 gallon totes (1040 liters) and bulk delivery. ' j Storage and Shelf Life Plastiment ES should be stored at above 40°F (50C). If frozen, thaw and agitate a1 thoroughly to return to normal state. Shelf life when stored in dry warehouse conditions between 40*F and 80eF (50C - 270C) is one 1 year. Typical Data Appearance Brown Liquid p Specific Gravity Approximately 1.2 CAUTION: IRRITANT. Contains Carbohydrates (Mixture). Slightly irritating to the eyes and skin. Handling and Storage Avoid direct contact. Wear personal protective equipment (chemical resistant goggles/gloves/clothing) to prevent direct contact with skin and eyes. Use only in well ventilated areas. Open doors and windows during use. Use a property fitted ' NIOSH respirator if ventilation is poor. Wash thoroughly with soap and water after use. Remove contaminated clothing and launder before reuse. - j First Aid Eyes — Hold eyelids apart and flush thoroughly with water for 15 minutes. Skin — ;a Remove contaminated clothing. Wash skin thoroughly for 15 minutes with soap and water. Inhalation — Remove to fresh air. Ingestion — Do not induce vomiting. Dilute with water. Contact physician. In all cases contact a physician immedi- ately if symptoms persist. r' _{ Clean Up Use personal protective equipment (chemical resistant gloves/goggles/clothing). Without direct contact, sweep up spilled or excess product and place in suitable sealed container. Dispose of excess product and container in accordance with - s applicable local, state, and federal regulations. KEEP CONTAINER TIGHTLY CLOSED • KEEP OUT OF REACH OF CHILDREN • NOT FOR INTERNAL CONSUMPTION • FOR INDUSTRIAL USE ONLY All information provided by Sika Corporation ('Sika') concerning Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sika's current experience and knowledge of its products when property stored, handled and applied under normal conditions in accordance with Sike's instructions. In practice, the differences in materi- als, substrates, storage and handling conditions, actual site conditions and other factors outside or Sika's control are such that Slka assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at www.sikacorp.com or by calling 800-933-7452. Prior to each use of any Sika product, the user must always read and fallow the wamings and instructions on the product's most cur- rent Technical Data Sheet, product label and Material Safety Data Sheet which are available at www.sikaconstruction com or 800-933-7452. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the wamings and instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use. SIKH warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Technical Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and assumes all risks. Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTIBILITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS. Sika Corporation 201 Polito Avenue Lyndhurst, NJ 07071 Phone: (201)933-8800 Fax: (201)933-6225 wwwsikaconstrucdon.com Sika Canada Inc. 601, Delmar Avenue Pointe -Claire, QC H9R 4A9 Phone: (514)697-2610 Fax: (514) 697-3087 www.sika,ca 1-800-933-SIKA 0 @ �re�ira Regional Information and Sales Centers. For the location of your nearest Sika representative, contact your regional center. U.S.: North East Region: Fairless Hills, PA, Phone: (215) 295 -6600 North Cental Region: Marion, OH, Phone: (800) 851-1545 ® South East Region: Conyers, GA, Phone: (770) 760-1300 South Central Region: Mesquite, TX, Phone: (972) 289-6480 ® Western Region: Santa Fe Springs, CA, Phone: (562) 903-3650 Canada: Ontario: Mississauga, ON, Phone: (9D5) 795-3177, Alberta: Edmonton, AB, Phone: (780) 486-6111 QuaOty Cerdrloadm Numbers: Lyndhurst FM 69711 PS09000), FM 70421 (GS 9000), Merlon: FM 69715, Kmr.-. Chy: FM 69107, Sant. Fe Springs: FM 69406 Sika and Plastiment are registered trademarks. Made in USA. Printed in USA Product Data Sheet Edition 6.1.2009 Identification no. Plastiment ES Plastiment® ES Water -reducing and Retarding Admixture Description Plastiment ES is a water -reducing and retarding admixture. Plastiment ES meets the requirements of ASTM C-494 as Types B and D and AASHTO M194 Types B and D admixture. Applications Plastiment ES should be used when a controlled delay in set time or increase in slump life of concrete is desired. Plastiment ES can be utilized in concrete used for flatwork and horizontal or vertical slipform placements. Use of Plastiment ES provides a superior surface finish. Benefits • Improves slump life and delays set time of concrete 4, • Slows down the rate of cement hydration reaction and controls concrete temperature i ■ Provides sufficient time for proper placement and finishing of concrete without #, cold joints in hot weather conditions ■ In flatwork applications, Plastiment ES acts as a finishing aid, improves work- ability, controls bleeding and provides a superior surface finish R� • In mass concrete pours, Plastiment ES controls temperature rise and reduces the risk of thermal cracking ■ Reduces permeability and enhances durability by allowing to reduce the water cement ratio Fx�>. y.. • Improves early and later age compressive and flexural strength =''a • Improves homogeneity in the mix and reduces chances of segregation. Refer to ACI 305R Hot Weather Concreting for more information. Plastiment ES s -i does rint COnt91n ralrh Im rhlnririp nr env nfhor intcn4innnlly niirlcrl nhlnrirlcc How to Use Dosage Dosage rates will vary depending on factors such as materials used, concrete temperature, ambient temperature and specific requirements of the project. For general concrete applications, Sika recommends a dosage rate of 2 - 4 fl. oz./100 lbs. (130-260 ml/100 kg) of cementitious materials. Exact dosages for a particular application should be determined by conducting trial mixes. Dosages outside the recommended range can be used to meet specific project require- ments after conducting trial mixes. For more information please contact your local regional office or technical service department at 1-800-933-7452. Mixing Add Plastiment ES at the concrete plant. Measure required quantity manually or by automated dispenser. Add into the water line at the batch plant or directly into the concrete at the end of the mixing cycle. Do not mix with dry cement. Combination with other admixtures: Plastiment ES is compatible with other Sika admixtures. When used in combination with other admixtures, each admixture should be added to the concrete separately. Packaging Plastiment ES is available in 55 gallon drum (208 liter), 275 gallon totes (1040 liters) and bulk delivery. Storage and Shelf Life Plastiment ES should be stored at above 40'F (5eC). If frozen, thaw and agitate thoroughly to return to normal state. Shelf life when stored in dry warehouse conditions between 40°F and 80°F (50C - 27eC) is one 1 year. Typical Data Appearance Brown Liquid Specific Gravity Approximately 1.2 CAUTION: IRRITANT. Contains Carbohydrates (Mixture). Slightly irritating to the eyes and skin. :Handling and Storage Avoid direct contact. Wear personal protective equipment (chemical resistant K i i goggles/gloves/clothing) to prevent direct contact with skin and eyes. Use only in r well ventilated areas. Open doors and windows during use. Use a properly fitted k' NIOSH respirator if ventilation is poor. Wash thoroughly with soap and water after use. Remove contaminated clothing and launder before reuse. First Aid Eyes — Hold eyelids apart and flush thoroughly with water for 15 minutes. Skin 1 — Remove contaminated clothing. Wash skin thoroughly for 15 minutes with soap and water. Inhalation — Remove to fresh air. Ingestion — Do not induce vomiting. Dilute with water. Contact physician. In all cases contact a physician immedi- ately if symptoms persist. }I Clean Up Use personal protective equipment (chemical resistant gloves/goggles/clothing). j Without direct contact, sweep up spilled or excess product and place in suitable Y r sealed container. Dispose of excess product and container in accordance with applicable local, state, and federal regulations. KEEP CONTAINER TIGHTLY CLOSED " KEEP OUT OF REACH OF CHILDREN " NOT FOR INTERNAL CONSUMPTION • FOR INDUSTRIAL USE ONLY All information provided by Sika Corporation ("Sika") concerning Sika products, Including but not limited to, any recommendations and advic relating to the application and use of Sika products, is given in good faith based on Sika's current experience and knowledge of its productse when Property stored, handled and applied under normal conditions in accordance with Sike's instructions. In practice, the differences in materi- als, substrates, storage and handling conditions, actual site conditions and other factors outside of Sike's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the pmduct(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at www.siKimro corn or by calling 800-933-7452. Prior to each use of any Sika product. the user must always read and follow the warnings and instructions on the products most cur- rent Technical Data Sheet, product label and Material Safety Data Sheet which are available at www ika on tructi- or 800. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use. SIKH warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties on the current Technical Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and assumes all risks. Buyer's sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor. NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTIBILITY OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHFH 1MTC11 CPTllnr — Pvrauvn Sika Canada Inc. 201 Polito Avenue 601, Delmar Avenue Lyndhurst, NJ 07071 Pointe -Claire, QC H9R 4A9 1-800-933-SIKA Phone: (201) 9333800 Phone: (514) 697-2610 Fax: (201) 9333225 Fax. (514) 697-3087 wwwsikaconstruction.com www.sika,ca Regional Information and Sales Centers. For the location of your nearest Sika representative, contact your regional center. U.S.: North East Region: Fairless Hills, PA, Phone: (215) 295 3600 North Central Region: Marion, OH, Phone: (800) 851-1545 ® South East Region: Conyers, GA, Phone: (770) 760-1300 South Central Region: Mesquite, TX, Phone: (972) 2893480 Western Region, Santa Fe Springs, CA, Phone: (562) 9033650 Canada: Ontario: Mississauga, ON, Phone: (905) 7953177, Alberta: Edmonton, AB, Phone: (780) 486.6111 Quality Certirication Numbers: l yndhumt FM 69711 (ISO 8000), FM 70421 (QS 9000), Marion: FM 60715, Kansas Clqr, FM 69107, Santa Fe Springs: FM 69408 Sika and Plastiment are registered trademarks. Made in USA Printed in USA