Westhaven Phase 2B-160905Concrete Mix Design Westhaven Ph. 2B Coppelljexas 36000PST Machine Pour 4000PSI Hand Pour 6331 Southwestern Blvd., Ben Brook, Texas. 76132 Office: 817.735.1600 Fax: 817.735.1613 September 5 ,2016 City of Coppell Engineering Dept Rick O'Dell Re: Westhaven Ph. 2B Dear Sir: Please find enclosed our proposed Mix Design Submittal for the above referenced project We have attached the relevant Technical Data Sheets on all the materials and admixtures for the designed concrete mixes. These designs are in accordance with ASTM C94, ACI 211. Once approved please sign and return or fax the copy letter to us. Assuring you of our best intentions. l Sincerely, ' 10 QA/QC Representative 6331 Southwestern Blvd., Ben Brook, Texas. 76132 ofrice:817.735.1600 Fax: 817.735.1613 Date: September 5,2016 Client CalAtlantic Homes Design Strength 360OPSI Machine Project Westhaven Ph. 2B Design Slump: 1-3" Location: Coppell,Texas Design Air Content: 3-6% Project No.: 1103 Water/Cmt Ratio: 0.45 Mix 4 360OMP Temperature Spec. 95 Degree Max S.S.D. ABS Materials Source SA. Gr, Weights Volume Cement Holcim Type 1-11 C-150 3.15 517 lbs. 2.63 Flyash Headwaters Martin Lake Class F 2.45 Moisture Adj. 0 lbs. 0.00 Coarse Agg. Hanson Bridgeport #57 2.66 1%1919 1900 lbs. 11.45 Fine Agg. US Concrete Red River C-33 2.62 5%1336 1272 lbs. 7.78 AEA Chryso Air 316 C-260 0.43 oz / cwt 3.00 oz. 1.08 WR/RT Chryso Tard CE -R C-494 3.00 oz 1 cwt 15.50 oz. 0.00 MRWR Chryso Optima C-494 0.00 oz 1 cwt 0.00 oz. 0.00 Water City Potable 1.00 253.80 lbs. 4.07 Total Wt. 3942.80 lbs. 27.00 Total Cementious Materials: 5.50 Sack Flyash Percentage: 0% City Spec, Unit Wt. 147,30 pcf Dry Rodded Unit Weights: Aggregate Specification: Coarse Aggregate 1044 pcf ASTM 57 &467 TxDot Grade 2,3,4 Abs. 0.9% Fine Aggregate 11134 pcf. ASTM C-33 TxDot 421 Abs. 1.0% Misc. Notes: I) These designs are in accordance with ASTM C-94 and ACI 211. Submitted by. QAIQC 6331 Southwestern Blvd., Ben Brook, Texas. 76132 Office: 817.735.1600 Fax: 817.735.1613 6331 Southwestern Blvd., Ben Brook, Texas. 76132 office: 817.735.1600 Fax: 817.735.1613 Date: September 5,2016 Client CalAtlantic Homes Design Strength 4000PSI Formwork Project Westhaven Ph. 2B n Slump: Design 3-5" Location: Coppell,Texas Design Air Content: 3-6% Project No.: 1103 Water/Cmt Ratio: 0.45 Mix 4000HP Temperature Spec. 95 Degree Max S.S.D. ABS Materials Source Sp. Gr. Weights volume Cement Holeim Type 1-11 C-150 3.15 564 lbs. 2.87 Flyash Headwaters Martin Lake Class F 2.45 Moisture Adj. 0 Ibs. 0.00 Coarse Agg. Hanson Bridgeport 957 2.66 1%1919 1850 lbs. 11.15 Fine Agg. US Concrete Red River C-33 2.62 5%1336 1282 lbs. 7.84 AEA Chryso Air 316 C-260 0.43 oz 1 cwt 3.00 oz. 1.08 WRIRT Chryso Tard CE -R C-494 3.00 oz I cwt 16.80 oz. 0.00 MRWR Chryso Optima C-494 0.00 oz / cwt 0.00 oz. 0.00 Water City Potable 1.00 253.80 lbs. 4.07 Total Wt. 3949.80 lbs. 27.00 Total Cementious Materials: 6.00 Sack Flyash Percentage: 0% City Spec. Unit Wt. 146.30 pcf Dry Rodded Unit Weights: Aggregate Specification: Coarse Aggregate 1044 pcf ASTM 57 &467 TxDot Grade 2,3,4 Abs_ 0.9% Fine Aggregate 11 l _34 pCf. ASTM C-33 TxDot 421 Abs. 1.0% Misc. Notes- 1) These designs are in accordance with ASTM C-94 and AC! 211. Submitted by: QAIQC Repre ntative 6331 Southwestern Blvd., Ben Brook, Texas. 76132 office: 817.735.1600 Fax: 817.735.1613 + Material: Portland Cement Holder Type: l-li Material Certification Report Test Period: 01 -Jun -2016 to 30 -Jun -2016 Date lssued: 11 -Jul -2016 Certification This cement meets the specifications of ASTM C150 for Type 1-11 cement. General Information Supplier: Hoicim (US) Inc Source Location: Midlothian Plant Address: 1800 Dove Lane 1800 Dove Lane Mid£othian, TX 76065 Midlothian, TX 76065 Contact: Javier Sosa / (972) 923-5800 Contact: The following is based on average test data during the test period. The data is typical of cement shipped by Holcim; individual shipments may Test Data on ASTM Standard Requirements Chemical Physical Item Limit' Result Item Limit ' Re"°` Sioz (%) - 20.2 Air Content (%) 12 max 8 AI2.03 (%) 6.0 max 4.8 Blaine Fineness (m2/kg) 260 min 372 Fe�03 {%) 6.0 max 3.2 64.0 Autoclave Expansion (%) (C151) 0.80 max 0.01 Cao (%) MgO {%) 6.0 max 0.8 Compressive Strength MPa (psi) Fe2O3 (%°) 1.4 - CAF (/°) 2 3.0 max 3.4 3 day 14.0 (1450) min 26.9 (3900) Si73 Loss on Ignition (%) g 3.5 max 2.2 7 day 17.0 (2470) min 32.6 (4730) Insoluble Residue (%°) 1.50 max 0.56 1.2 Initial Vicat minutes 45-375 107 CO2 (%) - CaCO3 in Limestone (%) 70 min 77 Potential Phase Compositions 3' C3S (%) - 57 C2S (%) 14 C3A (%) 8 max 7 CAF 10 C3S + 4.75C3A N - 91 Test Data on ASTM optional Requirements Chemical I Physical Item LimitResult Item Limit' Kesun Fquivalent Alkalies - 0.62 Mortar Bar Expansion (%) (C1038) 0.006 Notes (*1-9) 1 - Dashes in the Limit / Result columns mean Not Applicable. 2 - it is permissible to exceed the specification limit provided that ASTM Mortar Bar Expansion does not exceed 0.020% at 14 days. 3 - Adjusted per Annex A1.6 of ASTM 0150 and AASHTO M85. 5 - Limit = 3.0 when limestone is not an ingredient in the final cement product For Moderate Alkali 6 - Maximum total alkali, based on a 95% confidence interval level per TxDOT DMS 4600. Additional Data Item Limestone Inorganic Processing Addition I Base Cement Phase Composition Result Amount (%) 3.6 - C3S (%) 59 14 Si02 N 9.4 - Czs (%) 7 A603 (%) 3.1 - C3A (%a) 10 Fe2O3 (%°) 1.4 - CAF (/°) Cao {%) 44.0 SO3 (%) 0.9 - Printed: 7/11/2016 10.46:54 AM Version: 160627 HLAADWATERS RESOURCES Adding Value to Energy 'rm Headwaters Resources certifies that pursuant to ASTM C-618-15 protocol for testing, the test data listed herein was generated by applicable ASTM methods and meets requirements of ASTM C-618 and AASHTO M-295 and TX. DOT DMS-4610 (Producer Code 99097) for Class F fly ash. Report of Class "F" Fly Ash Martin Lake Plant Tatum Texas Unit #2 Silo #1 DATE: April 1, 2016 LABORATORY NUMBER: ML #3-2/15/16 MTRF #420 ML COMPOSITE DATE 2/9/16 -- 2/15/16 ASTM C-618-15 TX. DOT DMS-4610 SPECIFICATIONS SPECIFICATIONS CHEMICAL ANALYSIS Silicon Dioxide (SiO2) Aluminum Oxide (A1203) Iron Oxide (Fe203) Sum of Side, AI203, & Fe203 Magnesium Oxide (MgO) Sulfur Trioxide (S03) Moisture Content Loss On Ignition Sodium Oxide (Na2O) Potassium Oxide (K20) Total Alkali as Na2O equivalent Calcium Oxide (CaO) PHYSICAL ANALYSIS Fineness: Amount retained on 325 sieve % Water Requirement, % Control Specific Gravity Autoclave Expansion, % Strength Activity Index With Portland Cement, 7 Day 28 Day 57.11% 19.21% 5.12% 81.44% 3.12% 0.56% 0.05% 0.25% 0.62% 1.50% 1.61% 10.40% CLASS C CLASS F CLASS C CLASS F 50 Min. 70 Mica. 50 Min 70 Min, 5.0 Max. 5.0 Max. 5.0 Max. 5.0 Max. 3.0 Max. 3.0 Max. 2.0 Max. 2.0 Max. 6.0 Max. 6.0 Max. 3.0 Max. 3.0 Max. 20.51 % 34%m Max. 34% Max. 34% Max. 34% Max. 95% 1050/oMax 105%Max 105%Max 105%Max 2.45 -0.03% 0.8% Max 0.8% Max 0.8% Max 0.8% Max 85 % 75%u Min 75% Min. 75% Min. 75% Min. 90% 75% Min. 75%e Min. 75% Min. 75% Min. AUTHORIZED SIGNATURE-: P.O. Box 38 Thompsons, Texas 774 81-003 8 P: 281.343.0079 F: 281.343.0872 own s ■n Manson KIDEL6ERGCEMENTGroup Hanson Aggregates Southwest Region Technical Services Lab 1000 N. MacArthur Blvd. Grand Prairie, TX 75050 Tel. 972-260-3646 Fax. 972-260-3655 www.hansonpic.com MATERIALS EVALUATION Coarse Aggregates Source: Hanson a Bridgeport (Perch -Hill) Plant Technical Services #777 Type: ASTM #57 (1" - #4) Crushed Lime Stone Report: 2016-777 Lab NO: TS -Weekly -16 Date: 04-24-16 Date: Received: 04-01-16 ASTM METHOD TEST DESCRIPTION TEST RESULTS ASTM C-33 Specification C-136 2" Sieve 100 % Passing -------- C-1.36 1-112"Sieve 100 %Passing 100 C-136 1" Sieve 96 %Passing 95-100 C-136 314" Sieve 84 % Passing -------- C-136 112" Sieve 46 % Passing 25-60 C-136 318" Sieve 28 % Passing ------- C-136 #4 Sieve 6 % Passing 0-10 C-136 #8 Sieve 3 % Passing 0-5 C-136 #16 Sieve 2 % Passing -------- C-117 Decant (- 9200 Sieve Washed) 1.0 % Passing 1.5% Max. C-127 Relative Bulk Specific Gravity, SSD 2.663 C-127 Relative Bulk Specific Gravity, Dry 2.632 C-127 Absorption, 0.9 % C-29 Unit Weight (Dry Rodded), 104.4 Lbs/Cu.Ft. C-29 Unit Weight (Dry Loose), 94.1 Lbs/Cu.Ft. C-29 Voids Content (Dry Rodded), 38.3 % C-131 L.A. Abrasion, 26.8 %° Loss 50%° Max. C-1260 Potential Alkali Reactivity of Aggregates, 0.03 % Exp. 0.1 % Max C-88 Soundness by Sodium Sulfate (5 cycles), .............. 2.30 %g Loss 12% Max. C-88 Soundness by Magnesium Sulfate (5 cycles), ............... 3.20 % Loss 18% Max. C-123 Light Weight Pieces, 0.01 % 0.5% Max. C-142 Clay Lumps and Friable Particles, 0.01 %n 3.0% Max. C-25 Calcium Cat•bonate EQV, 96.0 % A ,, C-25 Acid Insoluble residue. 4.0 % D-4791 Flat Particles 4.1 % D-4791 Elongated Particles .... 3.4 Note: - Hanson Product Code TX -130 Vartan Babakhanian, P.E. Technical Services Lab Manager Onr letters, analysis and reports are for the exclusive use of the client to wham they are addressed, apply only to the samples tested and/ or inspected and are not necessarily indicative of the qualities of apparently identical or similar products. This report shall not be rep€oduced except in ful I andwith the writlen approval of HANSON PLC. CONCRETE FINE AGGREGATE GRADATION 100 % Concrete Sand Source: Product: Sample Date: Report Date: Tested by: REDI-MIX CONCRETE Red River Fine Aggregate, ASTM C33 Section 5.1 6128116 716116 DD Percentage ASTM SPECS TxDOT SPECS Sieve mm /Ret %Pass - - 1112 38.10 0 100 - - 1 25.40 0 100 314" 19.00 0 100 100 100 112" 12.70 0 100 100 100 318" 9.51 0 100 100 100 #4 4.76 6 95 95-100 95-100 #8 2.38 19 81 80-100 80-100 #16 1.19 30 70 50-85 50-85 #30 0.60 41 60 25-60 25-65 #50 0.30 88 13 05-30 10-35 #100 0.15 98 3 0-10 0-10 Pan 100 0 - - #200 (Decant) J. 7ABS% 0.70 - 2.8 1 0-3 2.3-3.1 0-3 2.3-3.1 S.G. 2.62 Dry Rodded Weight (lbs.fc.f) Tex 203E S.E.% Voids Tex 408A Organic Impurities Tex 413A % Deleterious Laboratory Manager 3 �= CURYSO �, ... CHRYSQ°Air 316 This makes it impossible to predict the dosage required for a specific mix requirement. As a guide, the dosage will generally be in the range of 0.05 to 0.25 litres/100 kg of cement to obtain an air content of 5% ± 2% in a medium workability concrete of 300-350 kg/m3 cement content. Where cement replacement materials are used they should be included in the cementitious content when calculating admixture dosage_ Mixes containing only OPC will usually require dosage in the lower half of the normal range. Mixes containing PFA or microsilica are more likely to require dosages in the higher part of the range. The use of lower quality PFA may increase the dosage required, possibly extending the normal maximum dosage up to 0.40 litres1100 kg. Storage Minimum shelf life of12 months provided the product is kept in a temperature between 5°C and 50°C Packaging • 25 litres — 200 litres • Flobins SAFETY Instructions for use A number of factors can affect the air entrainment obtained for a particular dosage of air entraining admixture, some of which are listed below. The examples given of changes that these factors may make to a Concrete mix should be taken as guidelines only and the actual effects in any particular) situation confirmed in trials. a) Sands of apparently the same grading may!. have significantly different effects on the level of air entrainment, depending on factors such as silt; content, particle size distribution and particle' shape. Where changes in sand source or content must be made, or where sand varies within the same source, a careful check must be made on the effects on air entrainment b) Increased cement fineness or cement content will tend to decrease air content. Changes in cement source and type may also lead to changes in the admixture dosage required to obtain a particular air content. c) The presence of carbon or organic impurities may reduce the effectiveness of an air entrainer and require an increased dosage. This will not usually be a problem but care may be required when using PFA, certain pigments orlignite bearing sands. d) Increased concrete temperature will tend to reduce air entrainment. Typically a rise from 10°C to 32°C may halve the level of air. In normal mixing conditions daily fluctuations will not give significant variations. e) Variations of mixer type and transit time may change the level of air entrainment. Small losses may occur during pumping. These will generally be consistent for a given set of conditions. High air contents may significantly reduce pump efficiency over long pump distances. D Normal compacting procedures will not affect air entrainment. Prolonged vibration should be avoided. g) Increased dosages may be required at low workability levels to achieve the required air content. 26 Malcolm Moodie Crescent Jetpark Ext 30 011-395-9700 www.chrysox, Technical data sheet CHRYSO°Tard CE -R Chloride free set retarding water reducing/ plasticising admixture. Description CHRYSO®Tard CE -R is classified as a set retarding water reducing/plasticising admixture according to SANS 509342:2011 (EN 934-2:2009). The admixture thus induces the following major effects on a concrete mix: Produces the combined effects of a high range red ucinglplasticising admixture (primary function) and A set retarding admixture (secondary function) Advantages Water reduction significantly improves compressive strengths at all ages. CHRYSOOTard CE -R allows strength grades to be met at reduced cement content or increased workability. Water reduction enhances durability through production of low permeability concrete. Controlled retardation extends the working life and the stiffening time for ease of construction, minimising delay problems. Control of stiffening improves slip forming and assists in preventing the formation of cold joints in large pours. Chloride free, safe for use in pre -stressed and reinforced concrete. Standards CHRYSO®Tard CE -R conforms to EN 934-2:2009 (table 2) and conforms to the requirements of ASTM 0494 Type A and Type D. Revision number: 2 Date: 2014/10103 Supercedes: 2007705102 Physical and chemical properties Physical state: liquid Specific gravity (25°C): 1.250 (±0.02) Colour: brown pH: 11 (±2) Cl ions content < 0.1 % Na2O. e 1 % Solubility in water: miscible Application guidelines Use Suitable with all types of Portland cement Semi -dry concrete screeds Mixes containing fly ash, slag and silica fum Reinforcers or pre -stressed concrete Transport of concrete over long distances Dosage The optimum dosage of CHRYSO®Tard CE -R can only be established by using trial tests, taking into account local conditions affecting the workability of the fresh mix and the mechanical properties required of the concrete. Typical. ® By volume: 0.25 to 0.60 litres per 100 kg of cementitious material (including extenders) ® By weight: 0.31 to 0.75 kg per 100 kg cementitious material (including extenders) Range: i By volume: 0.24 — 0.60 litres per 100 kg of cementitious material (including extenders) ■ By weight_ 0.30 to 0.76 kg per 100 kg cementitious material (including extenders) CHOYSO CHRYSO Southern Africa (Pty) Ltd. Sharecall facility. 0361 CHRYSO Gauteng (head office): 26 Malcom Moodie, Crescent, Jet Park I T. +27(0)11 395 9700 I F: -x27(0)11 397 6644 1 W: www.chry5o.mm www h r ys o.com Technical data sheet CHRYS4°lard CE -R Chloride free set retarding water reducing/ plasticising admixture. Overdosage: An overdose of double the recommended amount may result in a significant increase in retardation. Provided that adequate curing is maintained, the ultimate strength of the concrete will not be impaired. The overdose will increase the plasticising effect of CHRYSO®Tard CE -R, allowing for increased water reduction and higher ultimate strengths. A significant rise in workability may lead to segregation and bleeding. The effects of overdosing will be further increased if sulphate resisting cement or 5CMs are used. Dispensing/mixing CHRYSO®Tard CE -R is completely miscible in water. CHRYSO®Tard CE -R should never be added to dry cement or to components of a mix that are dry. CHRYSOITard CE -R can be added to concrete using one of the following methods: 9 To the gauge water before mixing: CHRYSO®Tard CE -R should be added to approximately 90% of the concrete's total gauge water requirement (including admixture). The remaining 10% of the concrete's total gauge water requirement (without admixture) should be added in small increments until the target concrete workability is achieved. ® As a component of the mixing process: Should be added simultaneously with approximately 90% of the concrete's total gauge water requirement. ® To fresh mixed concrete in a readymix truck drum: Reverse the readymix truck Revision number: 2 Date: 2014,10103 S u p e rce des: 2 007!1)5102 drum to discharge at very slow revolutions. When the concrete reached the mouth of the drum, stop the drum. Place CHRYSO®Tard CE -R on the concrete and not onto any exposed surface of the drum interior. Change the direction of the drum onto mixing and thoroughly mix the concrete at maximum permissible drum rpm, in order to ensure effective dispersion of CHRYSO"Tard CE -R throughout the concrete. (a minimum of 1 minute per 1 cubic metre of concrete; therefore 6 cubic metres = 6 minutes). All CHRYSO"Admixtures should be added to the concrete separately and must not be mixed together. Storage CHRYSO®Tard CE -R has a shelf life of 12 months starting from the manufacturing date — provided no other chemicals are added to it. The product should be stored away from the rain and frost in clean, dry tanks. Prevent product from freezing. Packaging Bulk taker loads 1 000 litre flobin 200 litre blopak 25 litre jerrycan Health and safety This product is classified as harmless. CHRYSO will provide onsite assistance when requested. Refer to the material safety data sheet. Disclaimer: The information contained in this document is given to the best of CHRYSO's knowledge and is the result of extensive testing. However, this document will not under any circumstances be considered as a warranty involving CHRYSO's liability in case of misuse. Tests should be carried out before any use of the product to ensure that the methods and conditions of use of the product are satisfactory. CHRYSO specialists are at the disposal of the users in order to help them with any problems encountered. CHHYS0 C1-IRYSO southern Africa (Pry) ltd. Sharecall facility. 0861 CHRY50 h Q Gauteng (head office): 25 Malcom Moodie, Crescent, let Park I T: +27(0111 395 9700 1 F: +27(0)17 397 6644 1 W: v>rvwchryso.rbm