Loading...
Wrangler/Olympus Signal-161206 (2)LETTER OF TRANSMITTAL To: L.H. Lacy Company DATE:6-Dec-16 1880 Crown Dr. Suite 1200 JOB NUMBER:16111 Dallas, Tx. 75354 ATTENTION:Parker Lacy .RE:Cypress Waters #6 Submittals WE ARE SENDING YOU: _X_ Attached ___ Under Separate Cover via _________ The Following Items: _X_ Submittals ___ Contract ___ Plans ___ Copy of Letter ___ Change Order ___ Brochure COPIES NO.DATE 1 6-Dec THESE ARE TRANSMITTED AS CHECKED BELOW: _X_ For Approval ___ Approved as Submitted ___ Resubmit___Copies for Approval ___ For Your Use ___ Approved as Noted ___ Submit ___ Copies for Distribution ___ As Requested ___ Returned for Corrections ___ Return ___ Corrected Prints ___ Other ___ For Review & Comment ___ For Bids Due ___ Prints Returned To Us After Loan REMARKS: Please review the mix design and approve. COPY TO: SIGNED: Heath Fox, PM 972-484-8465 office Burnco Ready Mix Design (40U100AG) DESCRIPTION Submittal # Version 1 12/6/2016 TEXAS BOMANITE WATTERS BRANCH MCKINNEY TX Dear TEXAS BOMANITE, This letter will serve as a warranty and guarantee for the compressive strength of the concrete supplied to your project. This letter will warranty that the compressive strength and integrity of the concrete supplied to this project will meet or exceed the contract requirements. All Mixes and documentation is in accordance with ACI 318-14. Mix Code Description 40U100AG 4000 PSI 1" AE GU The guarantee covers the specified strength of the concrete when tested and evaluated in accordance with ASTM C172, C31, C39, and C94 (including proper initial curing as per ASTM C31 Section 10.1.2 ), and when the recommended procedures for placement and curing outlined in ACI 305 and ACI 306 are followed. Additional items such as compliance with air content and concrete temperature at the time of delivery are subject to adjustment and variability as allowed within the submittal documents. Damage or deterioration that occurs to the concrete as a result of hazardous or aggressive chemical agents, improper or incorrect structural design, soil instability or movement, improper placement techniques, and/or acts of nature are not covered as part of this warranty. Acceptance of the concrete upon arrival at the point of delivery constitutes acceptance of this Limited Warranty. Sincerely yours, Gunter, QC MANAGER Concrete Mix Design Submittal Date :12/06/2016 1 4000 PSI 1" AE GU Mix Code :Description :40U100AG No.16--000380 Version Customer Contact Office Phone Project Name Project Contact Usage/ Placement TEXAS BOMANITE WATTERS BRANCH STAMPING Air Content Slump Unit Weight W/C Ratio Design Tolerance 5 3-5 lb/ft3 4.00 0.42 145.0 3-6 4000 psiDesign Strength Material Description Source Supplier ASTM STANDARD Design Quantity Specific Gravity Volume (ft3)Type Cement CEMENT GU 564 lbAshgrove Cement 3.13ASTM C-150 2.89 Coarse Aggregate 1" LIMESTONE 1783 lbHanson 2.65ASTM C-33 10.78 Fine Aggregate SAND 1330 lbTrinity 2.61ASTM C-33 8.17 Water WATER 238 lbCity 1.00ASTM C-1602 3.81 Admixture MID RANGE WATER REDUCER 7.0 /cwtBASF -ASTM C-494 - Admixture STANDARD AIR 3 lq ozBASF -ASTM C-260 - Yield 3915 --27.00lb Air Content 5.00 % --1.35 This mix has been designed to meet the requirements of this project based on the information sent to Burnco. The Specified strength guarantee per ASTM C94 will not be effective unless field sampling has been done per ASTM C172 and ASTM C31 and labora NOTES Prepared By : Gunter QC MANAGER BURNCO Texas LLC Mix No.:40U100AG Standard Deviation:337 Strength:4000 psi Average Strength:5268 ACI 318 5.3.2.1 Required average strength. (1)4452 psi (2)4285 psi 28 Day 3 Consecutive Date Temp.Slump Air %7 Day 28 Day 28 Day Average Average 6.4.16 90 4 4.5 4160 5520 5530 5525 7.9.16 90 5 4.7 4120 5360 5320 5340 7.9.16 88 5 5 4120 5260 5140 5200 5355 7.9.16 88 5 5.2 3820 4990 4850 4920 5153 7.9.16 88 5 4.3 3970 4860 4910 4885 5002 7.14.16 89 5 4.8 3860 5100 5240 5170 4992 7.16.16 88 5 4.6 3910 4720 4960 4840 4965 7.28.16 90 4.5 4.7 4030 4870 4920 4895 4968 8.1.16 91 5.5 4.5 3960 4850 4790 4820 4852 8.4.16 93 5.25 4.9 3900 4990 5030 5010 4908 8.18.16 87 5 5 4100 5010 4860 4935 4922 8.20.16 88 5.25 5.5 3850 4930 5100 5015 4987 8.21.16 88 5.5 4.6 3910 5100 5060 5080 5010 12.6.15 71 5 5.4 4230 5490 5360 5425 5173 12.9.15 72 5 4.8 4120 5540 5460 5500 5335 12.15.15 64 3 4.9 4200 5300 5400 5350 5425 12.15.15 65 4 4.2 4150 5250 5234 5242 5364 12.15.15 66 4 5.3 4120 5300 5350 5325 5306 1.10.16 58 4.5 5.3 3980 4875 4679 4777 5115 1.12.16 55 3.5 4.6 3850 4767 4876 4821.5 4975 1.25.16 62 6 5.5 4249 5125 5098 5111.5 4903 1.28.16 65 5 5 4150 5455 5345 5400 5111 2.5.16 66 5 5 4130 5266 5244 5255 5256 2.5.16 64 4.5 4.3 4350 5670 5530 5600 5418 2.5.16 64 4.75 4.2 4230 5560 5470 5515 5457 2.7.16 67 5 4.8 4120 5360 5320 5340 5485 2.7.16 61 4.5 4.5 4340 5470 5690 5580 5478 3.10.16 60 4.75 4.6 4430 5860 5760 5810 5577 3.10.16 52 4 4.2 4520 5980 5940 5960 5783 3.17.16 64 3 3.9 4400 5780 5980 5880 5883 BURNCO Texas LLC Mix No.:40U100AG Standard Deviation:337 Strength:4000 psi Average Strength:5268 ACI 318 5.3.2.1 Required average strength. (1)4452 psi (2)4285 psi 28 Day 3 Consecutive Date Temp.Slump Air %7 Day 28 Day 28 Day Average Average 3.17.16 67 4 4.3 4250 5760 5800 5780 5873