Loading...
Park West Crossing-LR170131 (4)PROFMIONAL NUS CE, INC. PO Box 118095 CARROLLTON, TX 75011 PHONE., 214-534-9942 FAX.- 972-492-4326 PROJECT.- PARK WEST CROSS/NG (SA N/TARYSEWER) CONTRACTOR: MA VER/CK UTILITY CONSTRUCT/ON CITY OF.- COPPELL, TX INSPECTOR: MATTHEW MASRY INSPECTION FIRM,- PROFESSIONAL INLINESERVICES OPERA TOR: MARTIN CAL V/LLO Contractor: MAVERICK UTILITY CONST Date: 1/31/2017 12:59:00 PM Pipe Type: PVC Job Name: PARK WEST Start ID: 5+15 CROSSING City: COPPELL End ID: 3+98 Length Surveyed: 115.1 Direction: Downstream Inspector: MATTHEW MABRY Grade: 1.5% Pipe Size: 8" WW -1 Operator: Martin Calvillo (0.0) Sl - Start Inspection (115.1) EI - End Inspection Total Distance: 115.1 Created with the ID Number: 5+15 �-`) ID Number: 3+98 report generator sack L Contractor: MAVERICK UTILITY CONST Date: 1/31/2017 1:05:00 PM Pipe Type: PVC Job Name: PARK WEST CROSSING Sart ID: 3+98 City: COPPELL End ID: 0+00 Length Surveyed: 405.3 Direction: Downstream Inspector: MATTHEW MABRY Grade: 1.5% Pipe Size: 8° VWV 1 Operator: Martin Calvillo (0.0) SI - Start Inspection (405.3) EI - End Inspection .... Total Distance: 405.3 Created with the ID Number: 3+98 ID Number: 0+00 report generator Back Contractor: MAVERICK UTILITY CONST Date: 1/31/2017 1:23:00 PM Pipe Type: PVC Job Name: PARK WEST Start ID: 3+20 CROSSING City: COPPELL End ID: 3+66 Length Surveyed: 37.1 Direction: Upstream Inspector: MATTHEW MABRY Grade: 0.5% Pipe Size: 8" WW 3 Operator: Martin Calvillo (0.0) SI - Start Inspection (37.1) EI - End Inspection Total Distance: 37.1 Created with the ID Number: 3+20 ID Number: 3+66 Nreport generator Back Contractor: MAVERICK UTILITY CONST Date: 1/31/20171:55:00 PM Pipe Type: PVC Job Name: PARK WEST Start ID: 3+20 CROSSING City: COPPELL End ID: 0+19 Length Surveyed: 305.5 Direction: Downstream Inspector: MATTHEW MABRY Grade: 0.5% Pipe Size: 8" WW -3 Operator: Martin Calvillo ID Number: 3+20 (0.0) SI - Start Inspection (305.5) EI - End Inspection Total Distance: 305.5 f, ID Number: 0+19 Created with the *: report generator Back J Contractor: MAVERICK UTILITY CONST Date: 1/31/2017 2:06:00 PM Pipe Type: PVC Job Name: PARK WEST Start ID: 0+19 CROSSING City: COPPELL End ID: 0+00 Length Surveyed: 16.1 Direction: Downstream Inspector: MATTHEW MABRY Grade: 0.5% Pipe Size: 8" WW -3 Operator: Martin Calvillo C*-') ID Number: 0+19 (0.0) SI - Start Inspection (16.1) EI - End Inspection Total Distance: 16.1 fr,NID Number: 0+00 Created with the report generator Back Contractor: MAVERICK UTILITY CONST Date: 1/31/2017 2:17:00 PM Pipe Type: PVC Job Name: PARK WEST Start ID: 0+39 CROSSING City: COPPELL End ID: 1+21 Length Surveyed: 73.7 Direction: Upstream Inspector: MATTHEW MABRY Grade: 0.5% Pipe Size: 8" WW -4 Operator: Martin Calvillo ID Number: 0+39 (0.0) SI - Start Inspection (73.7) EI - End Inspection Total Distance: 73.7 fiii, ID Number: 1+21 Created with the ` *� report generator Back Contractor: MAVERICK( UTILITY CONST Date: 1/31/2017 2:25:00 PM Pipe Type: PVC Job Name: PARK WEST Start ID: 0+39 CROSSING City: COPPELL End ID: 0+00 Length Surveyed: 34.5 Direction: Downstream Inspector: MATTHEW MABRY Grade: 0.5% Pipe Size: 8" WW -4 Operator: Martin Calvillo ID Number: 0+39 (0.0) SI - Start Inspection (34.5) EI - End Inspection Total Distance: 34.5 r, it ID Number: 0+00 Created with theme' reportgenerator Back Contractor: MAVERICK UTILITY CONST Date: 1/31/2017 2:29:00 PM Pipe Type: PVC Job Name: PARK WEST Start ID: 0+00 CROSSING City: COPPELL En 0: 0+70 Length Surveyed: 86.7 Dirrec-don: Upstream Inspector: MATTHEW MABRY Grade: 0.5% Pipe Size: 8" WW -2 Operator: Martin Calvillo (0.0) SI - Start Inspection (86.7) El - End Inspection Total Distance: 86.7 Created with the ID Number: 0+00 ID Number:IO+70 a r� report generator Back