Park West Crossing-LR170110 (3)Report Number: Service Date: Report Date: Task: Client Coppell, TX SEC Freeport Pkwy & Southwestern Blvd Park West Crossing - Phase 2ML Realty Partners Attn: Timothy Geisler One Pierce Pl Ste 450W Itasca, IL 60143 214-630-1010 Reg No: F-3272 Dallas, TX 75247-4547 8901 Carpenter Fwy Ste 100 94151183.0398 01/10/17 02/08/17 Revision 1 - 28-day results CONCRETE COMPRESSIVE STRENGTH TEST REPORT Project Project Number: 94151183 Specified Strength:28 days Mix ID: Supplier: Batch Time: Truck No.: 10J11504 Redi-Mix Material Information 0642 1496 Plant: Ticket No.: 236 25485762 Field Test Data Test Air Content (%): Result Specification 5 6.0 67 56 151.5 3,000 Slump (in): psi @ Concrete Temp. (F): Ambient Temp. (F): Plastic Unit Wt. (pcf): Yield (Cu. Yds.): Sample Information Sample Date: Sampled By: Weather Conditions: Sample Time:01/10/17 0715 Kaleb Womack Partly cloudy 10/20 10 0 0 40' N of SE corner of Bldg. GSample Location: Placement Method:Direct Discharge Water Added Before (gal): Water Added After (gal): Accumulative Yards:Batch Size (cy): Sidewalks at Bldg. G (N, E, & W Sides) Placement Location: Laboratory Test Data Set Avg Diam.Area DateDate Test Age at Load Maximum Strength Compressive Fracture No.ID Specimen Received Tested (days)Type(in)(sq in)(lbs)(psi) 1 1 4.00 12.57 01/17/17 7 49,335 2 3,930 1 2 4.00 12.57 02/07/17 28 57,485 2 4,570 1 3 4.00 12.57 02/07/17 28 56,845 5 4,520 1 4 4.00 12.57 02/07/17 28 55,800 2 4,440 Average (28 days) 4,510 1 5 4.00 12.57 03/07/17 56 Comments:Average compressive strength of 28 day cylinders complies with the specified strength. Samples Made By: Terracon Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Services: Reported To: Contractor: Report Distribution: (1) ML Realty Partners, Timothy Geisler (1) City of Coppell TX, Matthew Mabry (1) Halff Associates Inc, Hunter Starkey (1) ML Realty Partners, John Benson (1) O?Brien Architects , Richard Nordyke (1) Structure Tone Southwest Inc., Damon Renaud (1) Structure Tone Southwest Inc., Robin Povey (1) TechniStructures, Jason Owens James D. Baze Project Manager Structure Tone Southwest Reviewed By: ASTM C 31, ASTM C39, ASTM C138, ASTM C143, ASTM C172, ASTM C231, ASTM C1064, ASTM C1231Test Methods: Terracon Rep.: Kaleb Womack The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1CR0001, 11-16-12, Rev.6