Loading...
Fairfield Inn & Suites-170217PROJECT DETAILS 1. Project Name Fairfield Inn and Suites 2. Location/Address 1150 Northpoint Dr. 3. MS4 City of Coppell, TX 75019 4. County Dallas 5. Operator Name (control of daily operations)Northpoint Construction 6. Type Permit Small 7. Size-Acres 2.074 Location of SWP3 Manual / Site Map On-site office 10. Primary Site Contact: (Decides revisions & corrective action)James Anderson 11. Phone Number 214-600-3828 12. Primary Email Contact janderson@northpointconst.com 13. Additional email distribution list rhidalgo@northpointconst.com, jsmith@northpointconst.com 14. Inspection Schedule Every 7 Days (No Rain Events) 15. Type Of Construction Activity Hotel Construction 16. Sediment basins or ponds?Yes 17. Offsite Areas?No 18. Adjacent Wetlands?No 19. Critical Outfalls?No INSPECTION DETAILS Date of Inspection 02/17/2017 GPS Is this a Post Rain Event Report?Yes Is the Site Accessible Yes Construction Phase Utilities Batch Plant Exist?No SWPPP SITE INSPECTION REPORT Terradyne Group LLC Plano, TX SWP3 Fairfield Inn & Suites Submitted by Bryan Talley at 02/17/2017 08:02 CST Page: 1 Captured at 02/17/2017 08:02 CST gocanvas.com Submission ID: fb5e4aae7c549418-1487337973526 BMPS Inspector's Observation Regarding:SWPPP Sign Corrective Action Required No Location SE interior Additional Comments Recommend posting the CSN outside of the privacy screen visible to the public. Picture 1 Inspector's Observation Regarding:Curb Inlet Protection Corrective Action Required Yes Location Northpoint Dr, East of entry/exit Additional Comments The curb inlets are not protected, protection needs to be installed to minimize silt loss to the MS4. Picture 1 Inspector's Observation Regarding:Rock Entrance/ Exit Corrective Action Required No Location Off Northpoint Dr Additional Comments Observed the rock entry to be in good condition to minimize tracking. Picture 1 Inspector's Observation Regarding:Off-Site Streets Corrective Action Required No Location Northpoint Dr Additional Comments Observed a light amount of sediment along the curb line, recommend cleaning any sediment from the street. Picture 1 Inspector's Observation Regarding:Grate Inlet Protection Corrective Action Required Yes Location NW interior Additional Comments Observed debris piled on the inlet and damaged silt fencing, the debris needs to be cleaned away from the inlet, recommend repairing the silt fence protection at both North interior grate inlets. SWPPP SITE INSPECTION REPORT Terradyne Group LLC Plano, TX SWP3 Fairfield Inn & Suites Submitted by Bryan Talley at 02/17/2017 08:02 CST Page: 2 Captured at 02/17/2017 08:02 CST gocanvas.com Submission ID: fb5e4aae7c549418-1487337973526 Picture 1 Inspector's Observation Regarding:Perimeter Silt Fence Corrective Action Required Yes Location West perimeter Additional Comments Observed damaged and missing portions of silt fencing, repair the fencing to minimize silt loss to the off site bar ditch. Picture 1 Inspector's Observation Regarding:Loose Floatable Debris Corrective Action Required No Location Site wide Additional Comments Observed a minimal amount of loose floatable debris, debris is being properly disposed of. Picture 1 Inspector's Observation Regarding:Secondary Fuel Containment Corrective Action Required No Location South interior Additional Comments Observed a fuel tank on site, it is double walled, recommend storing the fuel tank in a secondary spill prevention bin. Picture 1 INSPECTION SUMMARY Does the Site Operators Qualify for Permit Termination?No **** Did the Inspector See Evidence of Corrective Action Since the Last Report? No **** Additional BMP Controls are Required?Yes **** Some BMP Controls are Inadequate as Designed and Need Improvement No **** Has Illicit Discharge of Sediment Past the Project Limits Occured?No **** BMP Controls Need Maintenance or Repairs?Yes SWPPP SITE INSPECTION REPORT Terradyne Group LLC Plano, TX SWP3 Fairfield Inn & Suites Submitted by Bryan Talley at 02/17/2017 08:02 CST Page: 3 Captured at 02/17/2017 08:02 CST gocanvas.com Submission ID: fb5e4aae7c549418-1487337973526 **** Summary of Observed Corrective Action Required:Repair silt fencing, maintain grate inlet protection, protect exterior curb inlets SWPPP SITE INSPECTION REPORT Terradyne Group LLC Plano, TX SWP3 Fairfield Inn & Suites Submitted by Bryan Talley at 02/17/2017 08:02 CST Page: 4 Captured at 02/17/2017 08:02 CST gocanvas.com Submission ID: fb5e4aae7c549418-1487337973526 COMPLIANCE SUMMARY No incidences of non-compliance was observed. The site is in compliance with the TXR150000 permit **** Non-compliance incidences have been noted. All non-compliance issues should be resolved within 7 days or immediately if a rain event is imminent **** Certification Statement ÒI certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is to the best of my knowledge and belief, true, accurate, and complete. I am aware there are specific penalties for submitting false information, including the possibilities of fine and imprisonment for knowing violations.Ó **** Printed Name Bryan Talley Date 02/17/2017 Inspector Phone Number 469-818-5854 Website Link http://. *** Please print this report double-sided. 1. File this report in your SWP3 Manual; keep 3 years after project completion for possible audit. 2. Log all changes to Operator responsibilities; ie areas sold to others; new Operator. 3. Update SWP3 Logs and SWP3 Site Map with current revisions. SWPPP SITE INSPECTION REPORT Terradyne Group LLC Plano, TX SWP3 Fairfield Inn & Suites Submitted by Bryan Talley at 02/17/2017 08:02 CST Page: 5 Captured at 02/17/2017 08:02 CST gocanvas.com Submission ID: fb5e4aae7c549418-1487337973526