Freeport NIP(1)-LR 841116 SOIL AND FOUNDATION ENGINEERING / CONSTRUCTION MA TERIALS TESTING
HOUSTON: 2055 Silber Rd.. Sa/re IOOB (77055) Phone: 7131956-2130
.= DALLAS: 8585 N. 5temmons Fwy. South Tower, Suite 770 (75247) Phone: 214/631-4990
FIELD SOIL MOISTURE - DENSITY TEST REPORT
TO DATE
Secure Resources, Inc cc: Ginn Inc. - Paul Lusk
P.O. Box 45309
Dallas, Texas 75235
p~¥ion: Ed Alexander R£PORT NO. 84-631C-10
Freeport North Industrial Site/Coppe~LD-'-'
TEST
DATA
% OF
SUBGRADE DRY DENSITY MOISTURE MAXIMUM
TEST FiLL LOCATION LBS./CU. FT. %
NO. LIFT NO. DENSITY
1 Storm Sewer Sta 24 + 60 Top 94.3 28.8 97.2
1 Storm Sewer Sta 23 + 00 12' Down 89.5 30.1 92.3
FIELD TEST METHOD: [-I VOLUMETRIC ASTM D-2167-77 I~ NUCLEAR ASTM, O-2922-81 [] SAND CONE ASTM, D-155~74
Tan Clay
TYPE OF MATERIAL
MAXIMUM DRY DENSITY 97 PCF OPTIMUM MOISTURE S°) . ~ PERCENT
METHOD OF TEST: I~ STANDARD ASTM, D-698 [] MODIFIED ASTM, D-1557
90
PERCENT COMPACTION REQUIRED PERCENT
-NOTE: TEST RESULTS COMPLY WITH PROJECT SPECIFICATIONS EXCEPT THOSE MARKED*
Rickards
INSPECTOR: TIME: