Loading...
Westhaven Phase 2B-LR170322Concrete Compression Test Report 2209 Wisconsin St. Dallas, TX 75229 (972)620-8911 Alpha Testing, Inc. TBPE Firm No. 813 FIELD DATA Placement Location:INLET, THROATS @ STATION 1+29.90 OF LAT Q-1 & STATION 7+26.03 ON LINE SD-Q Project Desc:WESTHAVEN PHASE 2B - UTILITIES OFF STATE HWY 121 AND WESTHAVEN RD. Our Report #:162997-24 CULLUM CONSTRUCTION 6440 NORTH CENTRAL EXPRESSWAY, SUITE 500 DALLAS, TX 75225 BUBBA THOMASONATTN: (972) 271-4881Fax Number: Date Placed:3/10/2017 Time Placed:12:30 PM 2.75 3.1 66 79 Date Received:3/11/2017 Concrete Supplier:LMC Submitted By:Garcia, Cristian Plant Number:952 Delivery Ticket No.:63011177 N/A Batch Time:11:28:00 AM Tested For: Lab No.: Cure Type: Date Tested: Age (Days): Max Load: Area: Sq. In.PSI: Cap Spec: CYLINDER COMPRESSION TEST RESULTS (ASTM C-231) Avg. Length Avg. Width Avg Depth/ Diameter Cast By:ALPHA Cured Specification:ASTM C-31 Mix ID:1701 Break Type: Sample Location:@ STATION 1+29.90 OF LAT Q-1 PM:ATTEF ABUSHAKRA, P.E. Date Issued:03/22/2017 Specified Strength:4000 Result Air Content: Ambient Temp (F): Concrete Temp (F): Unit Weight: Slump (ASTM C-143): 33 3/17/2017 7 5217312.56 4150LABC-1231 8 N/A 42 34 4/7/2017 28 012.56LABC-1231 8 N/A 4 35 4/7/2017 28 012.56LABC-1231 8 N/A 4 36 4/7/2017 28 012.56LABC-1231 8 N/A 4 CC:city of Coppell Respectfully Submitted By:__________________________________________________________ of Alpha Testing, Inc. Geotechnical Engineering * Construction Materials Testing * Environmental Engineering * Consulting 270143 Break Types: 1: Cone 2: Cone and Split 3: Cone and Shear 4: Shear 5: Columnar * = Specification out of spec Test Method: Unless noted, concrete was sampled and tested in accordance with ASTM C172, C143, C231, C173, C1064, C31, C1231 and C138. Compression strength tests per ASTM C39.