Loading...
Fairfield Inn & Suites-170310PROJECT DETAILS 1. Project Name Fairfield Inn and Suites 2. Location/Address 1150 Northpoint Dr. 3. MS4 City of Coppell, TX 75019 4. County Dallas 5. Operator Name (control of daily operations)Northpoint Construction 6. Type Permit Small 7. Size-Acres 2.074 Location of SWP3 Manual / Site Map On-site office 10. Primary Site Contact: (Decides revisions & corrective action)James Anderson 11. Phone Number 214-600-3828 12. Primary Email Contact janderson@northpointconst.com 13. Additional email distribution list rhidalgo@northpointconst.com, jsmith@northpointconst.com 14. Inspection Schedule Every 7 Days (No Rain Events) 15. Type Of Construction Activity Hotel Construction 16. Sediment basins or ponds?Yes 17. Offsite Areas?No 18. Adjacent Wetlands?No 19. Critical Outfalls?No INSPECTION DETAILS Date of Inspection 03/10/2017 GPS Is this a Post Rain Event Report?No Is the Site Accessible Yes Construction Phase Paving Batch Plant Exist?No SWPPP SITE INSPECTION REPORT Terradyne Group LLC Plano, TX SWP3 Fairfield Inn & Suites Submitted by Bryan Talley at 03/10/2017 08:00 CST Page: 1 Captured at 03/10/2017 08:00 CST gocanvas.com Submission ID: fb5e4aae7c549418-1489152781073 BMPS Inspector's Observation Regarding:SWPPP Sign Corrective Action Required No Location SE corner Additional Comments Picture 1 Inspector's Observation Regarding:Rock Entrance/ Exit Corrective Action Required No Location Off Northpoint Dr Additional Comments Observed the rock entry to be in good condition to continue minimizing tracking. Picture 1 Inspector's Observation Regarding:Curb Inlet Protection Corrective Action Required No Location Northpoint Dr Additional Comments Observed the protection to be clean and to be filtering effectively. Picture 1 Inspector's Observation Regarding:Off-Site Streets Corrective Action Required No Location Northpoint Dr Additional Comments Observed a light amount of sediment accumulating along the curb line, recommend cleaning the sediment from the street. Picture 1 Inspector's Observation Regarding:Perimeter Silt Fence Corrective Action Required No Location West perimeter Additional Comments Observed a small portion of damaged silt fencing, no silt loss observed, recommend repairing the fencing to ensure containment. Picture 1 Inspector's Observation Regarding:Vehicle Tracking Corrective Action Required No Location North parking lot Additional Comments Observed light tracking exiting the site, recommend sweeping the tracking at this time. SWPPP SITE INSPECTION REPORT Terradyne Group LLC Plano, TX SWP3 Fairfield Inn & Suites Submitted by Bryan Talley at 03/10/2017 08:00 CST Page: 2 Captured at 03/10/2017 08:00 CST gocanvas.com Submission ID: fb5e4aae7c549418-1489152781073 Picture 1 Inspector's Observation Regarding:Trash Container Capacity Corrective Action Required Yes Location South interior Additional Comments Observed the trash container to be overfilled, empty the container, a proper dumpster is scheduled to be put on site. Picture 1 Inspector's Observation Regarding:Grate Inlet Protection Corrective Action Required No Location SW interior Additional Comments The grate inlet has been properly protected, silt loss is being minimized. Picture 1 Inspector's Observation Regarding:Concrete Washout Corrective Action Required Yes Location SE interior Additional Comments Observed concrete washout waste in the soil, properly dispose of the waste, use properly contained stations for future washout activity. Picture 1 INSPECTION SUMMARY Does the Site Operators Qualify for Permit Termination?No **** Did the Inspector See Evidence of Corrective Action Since the Last Report? Yes Corrective Action Completed:Disposed of loose floatable debris, protected grate inlet **** SWPPP SITE INSPECTION REPORT Terradyne Group LLC Plano, TX SWP3 Fairfield Inn & Suites Submitted by Bryan Talley at 03/10/2017 08:00 CST Page: 3 Captured at 03/10/2017 08:00 CST gocanvas.com Submission ID: fb5e4aae7c549418-1489152781073 Additional BMP Controls are Required?Yes **** Some BMP Controls are Inadequate as Designed and Need Improvement No **** Has Illicit Discharge of Sediment Past the Project Limits Occured?No **** BMP Controls Need Maintenance or Repairs?Yes **** Summary of Observed Corrective Action Required:Properly dispose of concrete washout waste, empty full trash container SWPPP SITE INSPECTION REPORT Terradyne Group LLC Plano, TX SWP3 Fairfield Inn & Suites Submitted by Bryan Talley at 03/10/2017 08:00 CST Page: 4 Captured at 03/10/2017 08:00 CST gocanvas.com Submission ID: fb5e4aae7c549418-1489152781073 COMPLIANCE SUMMARY No incidences of non-compliance was observed. The site is in compliance with the TXR150000 permit **** Non-compliance incidences have been noted. All non-compliance issues should be resolved within 7 days or immediately if a rain event is imminent **** Certification Statement ÒI certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is to the best of my knowledge and belief, true, accurate, and complete. I am aware there are specific penalties for submitting false information, including the possibilities of fine and imprisonment for knowing violations.Ó **** Printed Name Bryan Talley Date 03/10/2017 Inspector Phone Number 469-818-5854 Website Link http://. *** Please print this report double-sided. 1. File this report in your SWP3 Manual; keep 3 years after project completion for possible audit. 2. Log all changes to Operator responsibilities; ie areas sold to others; new Operator. 3. Update SWP3 Logs and SWP3 Site Map with current revisions. SWPPP SITE INSPECTION REPORT Terradyne Group LLC Plano, TX SWP3 Fairfield Inn & Suites Submitted by Bryan Talley at 03/10/2017 08:00 CST Page: 5 Captured at 03/10/2017 08:00 CST gocanvas.com Submission ID: fb5e4aae7c549418-1489152781073