Loading...
Fairfield Inn & Suites-170324PROJECT DETAILS 1. Project Name Fairfield Inn and Suites 2. Location/Address 1150 Northpoint Dr. 3. MS4 City of Coppell, TX 75019 4. County Dallas 5. Operator Name (control of daily operations)Northpoint Construction 6. Type Permit Small 7. Size-Acres 2.074 Location of SWP3 Manual / Site Map On-site office 10. Primary Site Contact: (Decides revisions & corrective action)James Anderson 11. Phone Number 214-600-3828 12. Primary Email Contact janderson@northpointconst.com 13. Additional email distribution list rhidalgo@northpointconst.com, jsmith@northpointconst.com 14. Inspection Schedule Every 7 Days (No Rain Events) 15. Type Of Construction Activity Hotel Construction 16. Sediment basins or ponds?Yes 17. Offsite Areas?No 18. Adjacent Wetlands?No 19. Critical Outfalls?No INSPECTION DETAILS Date of Inspection 03/24/2017 GPS Is this a Post Rain Event Report?Yes Is the Site Accessible Yes Construction Phase Paving/Building construction Batch Plant Exist?No SWPPP SITE INSPECTION REPORT Terradyne Group LLC Plano, TX SWP3 Fairfield Inn & Suites Submitted by Bryan Talley at 03/24/2017 12:15 CDT Page: 1 Captured at 03/24/2017 12:15 CDT gocanvas.com Submission ID: fb5e4aae7c549418-1490374244649 BMPS Inspector's Observation Regarding:SWPPP Sign Corrective Action Required No Location SE corner off Northpoint Dr Additional Comments Picture 1 Inspector's Observation Regarding:Off-Site Streets Corrective Action Required No Location Northpoint Dr Additional Comments Observed a minimal amount of tracking and silt in the street after the rain event, public streets are in good condition. Picture 1 Inspector's Observation Regarding:Curb Inlet Protection Corrective Action Required No Location Northpoint Dr Additional Comments Observed the curb inlet protection to be clean, the controls are filtering effectively. Picture 1 Inspector's Observation Regarding:Rock Entrance/ Exit Corrective Action Required No Location South entry/exit Additional Comments The rock at the exit point is wearing slightly thin, the operator is scheduled to add more rock to ensure tracking continues to be minimized. Picture 1 Inspector's Observation Regarding:Grate Inlet Protection Corrective Action Required No Location Site wide Additional Comments Observed grate inlet protection to be filtering effectively. Picture 1 Inspector's Observation Regarding:Perimeter Silt Fence Corrective Action Required No Location West perimeter Additional Comments Observed a portion of the silt fencing beginning to be undermined, no silt loss observed past the perimeter at this time. Picture 1 Inspector's Observation Regarding:(BOC) Below Grade Cut Corrective Action Required No Location North entry Additional Comments The dirt has been back filled, it is still slightly below grade, no silt loss observed after rain event. SWPPP SITE INSPECTION REPORT Terradyne Group LLC Plano, TX SWP3 Fairfield Inn & Suites Submitted by Bryan Talley at 03/24/2017 12:15 CDT Page: 2 Captured at 03/24/2017 12:15 CDT gocanvas.com Submission ID: fb5e4aae7c549418-1490374244649 Picture 1 INSPECTION SUMMARY Does the Site Operators Qualify for Permit Termination?No **** Did the Inspector See Evidence of Corrective Action Since the Last Report? Yes Corrective Action Completed:Repaired silt fencing **** Additional BMP Controls are Required?No **** Some BMP Controls are Inadequate as Designed and Need Improvement No **** Has Illicit Discharge of Sediment Past the Project Limits Occured?No **** BMP Controls Need Maintenance or Repairs?No **** Summary of Observed Corrective Action Required:No corrective action required SWPPP SITE INSPECTION REPORT Terradyne Group LLC Plano, TX SWP3 Fairfield Inn & Suites Submitted by Bryan Talley at 03/24/2017 12:15 CDT Page: 3 Captured at 03/24/2017 12:15 CDT gocanvas.com Submission ID: fb5e4aae7c549418-1490374244649 COMPLIANCE SUMMARY No incidences of non-compliance was observed. The site is in compliance with the TXR150000 permit **** Non-compliance incidences have been noted. All non-compliance issues should be resolved within 7 days or immediately if a rain event is imminent **** Certification Statement ÒI certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is to the best of my knowledge and belief, true, accurate, and complete. I am aware there are specific penalties for submitting false information, including the possibilities of fine and imprisonment for knowing violations.Ó **** Signature Printed Name Bryan Talley Date 03/24/2017 Inspector Phone Number 469-818-5854 Website Link http://. *** Please print this report double-sided. 1. File this report in your SWP3 Manual; keep 3 years after project completion for possible audit. 2. Log all changes to Operator responsibilities; ie areas sold to others; new Operator. 3. Update SWP3 Logs and SWP3 Site Map with current revisions. SWPPP SITE INSPECTION REPORT Terradyne Group LLC Plano, TX SWP3 Fairfield Inn & Suites Submitted by Bryan Talley at 03/24/2017 12:15 CDT Page: 4 Captured at 03/24/2017 12:15 CDT gocanvas.com Submission ID: fb5e4aae7c549418-1490374244649