Loading...
Freeport NIP(1)-LR 850807 (7)Maxim E~glr~e~:rs inc. Concrete Cylinder Test Re~. Date 08/07/85 Samp~ Date 07/31/85 Standard 6"x 12" Ama 28.27 ~uare inches To L.H. Lac5 Company P,oj~ Freeport North - Coppe]], Texas ~ntra~or L.H. Lacy Company ~rete Supplier and Plant L.H. Lacy Company - On-site plant MixNo. Location of Placement Pav~ ng, Freeport Road, stat~ on 8+00 Materials Source/ SSD Batch Wts. Description (Lbs./Cu./Yd, OtherData Cement Time Batched: FlyAsh Time Sampled: 4.';)5 p.m, Coarse Aggregate Ticket No.: Intermediate Aggregate Temperature: Ambient 9 1 · Concrete 80* Fine Aggregate Weather Conditions: U n Admixtures: 1. 2. Entrained A~r Content AddedWater 0 gal lons 5 Specimen Age Slump Total Load Compressive Strength Strength Required Number (Days) Date Tested In~ Lbs. PSI. P,S.I./days FPN 37 7 08/07/85 2 97700 3456 3000/28 38 28 (08/28/85) 39 28 (08/29/85) Curing ASTM C-31 Test Method I Cylinders Made i Fracture: Regular (UNO) By: ASTM C-39 ] S .K. Remarks and or D,strlbution ART S .K. L. H. Lacy Company - Neva Ransom (2) City of Coppell ~-