Security Fire Systems-PN170406TRENCH SAFETY PLAN UTILITY PLAN SECURITY FIRE SYSTEMS (IN AND AROUND 196 FREEPORT PARKWAY) COPPELL, TEXAS I; to] 1-4 SECURITY FIRE SYSTEMS, INC Note: Soil information indicates that a stiff clay (Type °B° soil) will be found on the project site. The following applies: H = 3/ in stiff clay (Type "B" soil or better) and unweathered limestone. H = 1 or greater in Type "C" soil $pass aaa■aaaaBaaua! RICHARD HAL.DER e go as Boas .l Now a a a ■as a ■f 75134 r Ak ;d;fat Trench Safety Plan for: MOSS UTILITIES Pg:1 of: 5 Security Fire Systems Job No: 8488 Trench Safety 16 Engineering (196 Freeport Parkway) Date: 06 Apr 2017 833 Rachelle 'Drive, Red Oak DOppell, Texas Scale: As shown Texas 75154 972-6'17-8370 Design: R.H. Richard Halder P.E. GENERAL NOTES This Trench Safety Plan was prepared under OSHA Subpart P Excavations and Trenches, 1926.652(b)(4)Option(4) & 1926.652(c)(4)Option(4). The plan deals with the retention of soil by natural or manmade means. This plan can -not state the where/haw/when/choice/etc of the contractor's procedures. To do so would be illegal. The contractor shall seek guidance from the Trench Safety Engineer when unanticipated solutions are required. THE FOLLOWING PAGES ARE ALLOWABLE SHORING OPTIONS. For all excavations of trenches, which will exceed a depth of five feet, the Contractors trench safety procedures shall meet the current standards established by OSHA on excavations, trenching, shoring, and confined spaces, all of which are incorporated herein by reference. 2. These drawings assume all excavated areas remain free of water seepage or intrusion. Excavations shall be inspected after every storm or other hazard - increasing occurrence to assure the continued safety of the trench. The Contractor shall seek guidance from the Trench Safety Engineer where needed. 3. When installing a support system, shoring will be applied by starting at the top of the trench excavation and working downward. All cross beams, trench jacks, etc., will be placed in a true horizontal position. Support system removal shall begin at the bottom and proceed upward, performed from outside the trench. 4. Alternate design for use of steeper slopes of the use of supporting systems, i.e_, piling, cribbing, shoring, etc., may be submitted by the Contractor for evaluation by the Trench Safety Engineer. 5. Slopes shown shall be the maximum unless changed by the Trench Safety Engineer due to changing soil conditions. Slopes shown are for a short-term period. If excavations are open for more than 24 hours, the Trench Safety Engineer shall be contacted for evaluation. 6. Cohesive soils are classified by their unconfined compressive strength, as follows: (psf = pounds per square foot; tons/sq ft = tons per square foot) Type "A"... more than 3,000 psf (1.5 tons/sq ft) Type "B more than 1,000 psf (0.5 tons/sq ft) and less than 3,000 psf (1.5 tons/sgft) Type "C"... less than 1,000 (0.5 tons/sq ft) that is not flowing or submerged. Trench Safety Plan for: MOSS UTILITIES Pg: 2 of: 5 Security Fire Systems Job No: 840$ Trench Safety Engineering (196 Freeport Parkway) Date: 06 Apr 2017 Scale: As shown F-6216 833 Rachelle Drive, Red Oak I Coppell, Texas Testas 75154 972-617-8370 Design: R.H. Richard Halder P.E. Note: Either sloped or benched is acceptable As Required TYPICAL OPEN CUT CROSS SECTION N.T.S. Trench Safety Plan for: MOSS UTILITIES Pg: 3 of:5 Security Fire Systems 'fob No: 8408 Trench Safety Engineering (196 Freeport Parkway) Date: 06 Apr 2017 ,833 Rachelle Drive, Red Oak Coppell, Texas Scale: As shown Texas 75154 972-617-8370 Design: R.H. Richard Halder P.E. Ix. Spaced 6' to 8' in unweathered limestone. Spaced 4' o.c. in stiff clay (Type "B" soii) and weathered limestone. Spaced 4' o.c. in dry Type "C" soil sheeted with 314", 14 -ply Finland Birch, or 1-118" plywood, or approved equal. "Standard" Hydraulic Shoring As Required TYPICAL HYDRAULIC CROSS SECTION N.T.S. Fft*4ft 2 10` max, Spoil As per manufacture's tabulated data and limits. Trench Safety Pian for: MOSS UTILITIES Pg: 4 of: 5 Security Fire Systems Job No: 8408 Trench Safety Engineering (196 Freeport Parkway) Date: 06 Apr 2017 F-6216 833 Rachelle Drive, Red Oak Coppell, Texas Scale; As shown Texas 75154 972-617-83710 Design: R.H. Richard Halder P.E. As Required Trench Box/Shield side wall capacity shall be equal or greater than 280 psf for Type "B" soil and equal or greater than 400 psf for Type "C" soil. If there are any changes is soil conditions, the Trench Safety Engineer shall be contacted for evaluation. Any manufactured/rated trench shield system, such as Manhole Rings, Modular Shields, Panel Shields, etc, are included in this catagory. Trench box capacity refers to sidewall capacity of bottom box when boxes are stacked. If "closed ends" are required, one acceptable method is by placing 3/4", or greater (or equal substitute) steel plate (width size may vary) against spreaders of trench box, Other methods may be used with approval of the Trench Safety Engineer. ALTERNATE TRENCH BOX CROSS SECTION N.T.S. max Trench Safety Plan for: MOSS UTILITIES Pg: 5 of: 5 Job No: 8408 Trench Safety Engineering Security Fire Systems Date: 06 Apr 2017 F-6216 (196 Freeport Parkway)Scale: As shown 833 Rachelle Drive, Red Oak Coppell, Texas Texas 75154 972-617-8370 Design: R.H. Richard Halder P.E.