Loading...
Eckerd's-LR 990104 (3) GEOTECHNICAL ENGINLA, NG J E J 'ENV' ONMENTALCONSULT'NG GEE Consultants, Inc. I EI CONSTRUCTION MATERIALS TESTING 10046 Monroe Drive · Dallas, Texas 75229 · (214) 352-5433 · Fax (214) 352-6972 REPORT OF IN-PLACE DENSITY AND MOISTURE OF SOIL Densit Report No. 11 (298-0412) Method: ASTM D2922 D3017 D698 Page of 1 Client: North American Properties Material Description Maximum Optimum Dry Moisture Density Content Project: Eckerds (Lbs/CuF0 Percent Coppeil, Texas 96.4 I. Dark Brown Clay 10';.3 12.6 Test Date: December 31, 1998(11:00 am) 2. Orange & Gray Clayey Sand (Select Fill} 3. Dark Brown Clay i00.2 19.2 Report Date: January 4, 1999 Required Density (%): 95% - 105% Required Moisture (%): Opt +5% (Clay) Opt :t:3% (Sand) Mat Location/Elevation (and/or) Lift In-Place In-Place Percent No. Dry Density Moisture Compaction Test (Lbs/CuFO Content (%) No. Probe Depth I 1st Lift 38 80' N. of detector check vault - 30" above fire line 89.2 20.8 92.5 * 6" * Test does not meets project specifications cc: Mr. John Maggiore - North American Properties Mr. Lance Lilly - Richmond Group Mr. Gary Stokes - C. A. Walker Construction Mr. Lee Stone - City of Coppeil t'N - Mr. Larry Davis - City of Coppeli ~~ Our letters and reports are for the exclusive use of the client to whom they are addressed. The use of our name[n~st.rece,ve o.ur .p.nor. w.r,tten.~.proval.. Our letters and reports apply only to the sample tested and/or inspected, and are not necessarily indicative of the quantl~s o~ apparenay i~lent~cal or s~mllar prooucts.