NL Cypress Ph 2-SP170420 Copyright Ó DART, all rights reserved, 2009
PLAN DATA INFORMATION TO BE INCLUDED ON DRAWINGS
For Underground Pipelines
CARRIER PIPE CASING PIPE
Contents to be handled Wastewater Carrier Pipe
Outside diameter 25.8 in.36.0 in.
Pipe Material HDPE Steel
Specifications and grade ASTM F 714
(DR 11/200 psi)ASTM A139 Grade B
Wall thickness 2.345 in.0.5625 in.
Actual working pressure 0 – 25 psi N/A
Type of joint Fusion
ASTM D2620
Welded ANSI/AWS
Section B2.1-206-96
Coating None None
Method of installation Boring Boring
Seals: Both ends Type: Manufactured Rubber Casing End Seal
Bury: Base of rail to top of casing: 11 ft. bury with rail elevated on wood bridge 8 ft.
Bury: (Not beneath tracks) 11 ft. 0 in. to 12 ft. 0 in.
Bury: (Roadway ditches) N/A
Type, size and spacing of insulators or supports: 8” Stainless steel casing spacers with
maximum 6.0 ft. spacing
Distance C.L. track to face of jacking/receiving pits: Approx. 55 ft. (south side),
approx. 65 ft. (north side)
Bury: Base of rail to bottom jacking/receiving pits: Approx. 25 ft.
Cathodic protection: No
SPECS:DART and/or AREMA (American Railway Engineering and Maintenance of Way Association)
specifications must be met. Attach Engineering Drawings that include Project Plan and Profile, North Arrow,
Right-of-Way Lines of Railroad corridor, and Public or Private streets. Identify location with nearest street
crossing the rail corridor and distance from center of street to the project. Provide a location map, surveys, mile
post, etc., as needed to identify location.
Page 3 of 3