Loading...
NL Cypress Ph 2-SP170420 Copyright Ó DART, all rights reserved, 2009 PLAN DATA INFORMATION TO BE INCLUDED ON DRAWINGS For Underground Pipelines CARRIER PIPE CASING PIPE Contents to be handled Wastewater Carrier Pipe Outside diameter 25.8 in.36.0 in. Pipe Material HDPE Steel Specifications and grade ASTM F 714 (DR 11/200 psi)ASTM A139 Grade B Wall thickness 2.345 in.0.5625 in. Actual working pressure 0 – 25 psi N/A Type of joint Fusion ASTM D2620 Welded ANSI/AWS Section B2.1-206-96 Coating None None Method of installation Boring Boring Seals: Both ends Type: Manufactured Rubber Casing End Seal Bury: Base of rail to top of casing: 11 ft. bury with rail elevated on wood bridge 8 ft. Bury: (Not beneath tracks) 11 ft. 0 in. to 12 ft. 0 in. Bury: (Roadway ditches) N/A Type, size and spacing of insulators or supports: 8” Stainless steel casing spacers with maximum 6.0 ft. spacing Distance C.L. track to face of jacking/receiving pits: Approx. 55 ft. (south side), approx. 65 ft. (north side) Bury: Base of rail to bottom jacking/receiving pits: Approx. 25 ft. Cathodic protection: No SPECS:DART and/or AREMA (American Railway Engineering and Maintenance of Way Association) specifications must be met. Attach Engineering Drawings that include Project Plan and Profile, North Arrow, Right-of-Way Lines of Railroad corridor, and Public or Private streets. Identify location with nearest street crossing the rail corridor and distance from center of street to the project. Provide a location map, surveys, mile post, etc., as needed to identify location. Page 3 of 3