Loading...
Freeport NIP(4)-CS 960118JAN--18--~G THU 0~ :0~ PM P.O2 January 18, 1996 Mr. Ken Griffin Assistant City Manager/City Engineer City of Coppell' 255 Parkway Boulevard Coppell, Texas 75019 Re: Freeport North Royal Lane at Creekview Drive GDA,Pr0j¢ct NO. 95066 Dear Mr. Griffin: Regarding the distribution warehouse currently being review by the City of Coppell, Texas, we would like to submit the following information. The paving design for this project shall be 6" thick, 4,000 psi concrete, reinforced with No. 3 steel bars at 24" o.c. each way. This paving section shall be placed over a compacted base. The geotechanicai report No. 2317.4, dated November 1995, as prepared by Reed Engineering includes this recommendation based upon their analysis of existing site conditions. We feel this design should perform satisfactorily for this project and request your approval. Should you required additional information or have any questions, please call me for assistance. Sincerely, /Ih cc: Rob Ahmuty, MEPC John Jacobson, McFadden Pat Acker, Halff & Assoc. File