Loading...
Security Fire Systems-CS170428FREEL I EMMInEEF4InIS GEOTECHNICAL AND G F=q 1D U F= ENVIRONMENTAL CONSULTANTS April 28, 2017 Project No. 21424 Security Fire System, Inc. 196 S. Freeport Parkway Coppell, Texas 75019 ATTN: Mr. Mike Alexander Re: Supplemental Geotechnical Recommendations Proposed Office/Warehouse 196 South Freeport Parkway Coppell, Texas Gentlemen: Submitted here is a supplemental geotechnical recommendation for the referenced project. It is understood that consideration is being given to use "flexible" base in lieu of the lime stabilization for the pavement in driveway and parking areas. "Flexible " base is defined as TxDOT Item 247, Grade 2, Type A (Crushed limestone) or crushed concrete meeting Grade 2 requirements. Six inches of "flexible" base is equivalent to eight inches of lime stabilization. "Flexible" base should be placed in accordance with the Earthwork section of our report. This should be confirmed by testing as outlined in the Construction Observation and Testing Frequency section. Both of these sections are provided in the original report. We appreciate the opportunity to present this information. If any questions arise, do not hesitate to call. Sincerely, REED ENGINEERING GROUP,.6 F T ��� Registration Number F-3114 s�S�P �/ 20/ 7 i� *. * �l OLA.......................................'`. -/ �.. SANDIP TAMRAKAR j Sandip amrakar, P.E. �j -o'. 125726 �i Project Engineer '1 NAL r Ronald F. Reed, P.E. Principal ST/RFR/mt copy submitted via e-mail only 2424 STUTZ DRIVE, SUITE 400 DALLAS, TX 75235 tel 214.350.5600 fax 214.350.0019 www.reed-engineering.com GEOTECHNICAL ENGINEERING ENVIRONMENTAL CONSULTING CONSTRUCTION MATERIALS TESTING