Loading...
Security Fire Systems-CS170502 Halie Hernandez From:Matthew Mabry Sent:Tuesday, May 02, 2017 2:09 PM To:Halie Hernandez Subject:SFS Traffic control plan Moss Utilities - Freeport Pkwy Attachments:Freeport Pkwy (Freeport Pkwy & Sandy Lake Rd) RLC.PDF Categories:This message has been archived by Retain on May 02 2017 17:31 Matthew Mabry Engineering Construction Inspector City of Coppell, TX 214-406-5223 (cell) www.coppelltx.gov From: Tommy White \[mailto:tommy@mossutilities.com\] Sent: Tuesday, May 02, 2017 1:59 PM To: Matthew Mabry <MMabry@coppelltx.gov> Subject: Fwd: FW: Moss Utilities - Freeport Pkwy Matt, Here are the changes you requested. As soon as you have approval I can schedule everything to get the water connection set up. Thanks! ---------- Forwarded message ---------- Christian Brown From: <christian@buyersbarricades.com> Date: Tue, May 2, 2017 at 1:54 PM Subject: FW: Moss Utilities - Freeport Pkwy To: Tommy White <tommy@mossutilities.com> -- Thank You, Tommy White 1 Superintendent Mobile: 817-721-0290 Mail: tommy@mossutilities.com Web: www.mossutilities.com 2 TCP DESIGNER SALESMAN/EXECUTIVE NOTES Phase 1 Sheet 1 Hamilton Duffy, PC Consulting Tex Reg F-5260 Chris Schreiner Eddie Harmon Jason Garrett Marie Rhom Michael Cooper Kevin Omachel Reedie Lea CONTACT NUMBER: Keith Hamilton Lauren Simpson Tony Troxclair Jill Smith Garrett White Christian Brown Right Lane Closure CONTACT: DATE: CITY: CONTRACTOR: JOB NAME: LOCATION: SCOPE OF WORK: Freeport Pkwy & Sandy Lake Rd Freeport Pkwy Coppell Moss Utilities Tommy White 85ft Buffer120ft 245ft Taper 320ft Taper 170ft Buffer240ft 400ft 415ft Buffer 720ft Taper 780ft Taper Lindsay Garrett Jessica Paredes Arrow Board MB TMA Type 1 Type 2 Type 3 817-721-0290 05/01/2017 Part A Mike Moreno 50ft Work Zone 100ft Work Zone 150ft Work Zone 200ft Work Zone 250ft Work Zone 300ft Work Zone 350ft Work Zone 400ft Work Zone 450ft Work Zone 500ft Work Zone 1000ft Work Zone 1500ft Work Zone ROADWORKAHEADCW20-1D CW20-5R RIGHTLANECLOSED CW20-5DL LEFTLANECLOSEDAHEAD RIGHTLANECLOSEDAHEADCW20-5DR TURNLANECLOSEDCW20-5T CENTERLANECLOSEDCW20-5C ROADCLOSEDAHEADCW20-3D DETOURAHEADCW20-2D ONE LANEROADAHEADCW20-4D BEPREPAREDTOSTOPCW3-4 CW20-7 LANE ENDSMERGERIGHTCW9-2TR LANE ENDSMERGELEFTCW9-2TL 2RIGHT LANESCLOSEDCW20-5aTR SHOULDERWORKCW21-5 ROADNARROWSCW5-1 TRUCKSENTERINGROADWAYCW27-1T CW3-2 CW4-3R CW4-3L CW21-1aT CW1-4L CW1-4R CW6-3 CW12-1 CW12-1 CW12-1 ENDROAD WORKG20-2ENDROAD WORKG20-2CW20-5LLEFTLANECLOSEDTOONCOMINGTRAFFICR1-2YIELDR1-2 APTOONCOMINGTRAFFICYIELDR1-2R1-2 AP STOPR1-1R5-1YIELDR1-2WRONGWAYR5-1aG20-1bR NEXT MILESXXROAD WORKNAMEADDRESSCITYSTATECONTRACTORG20-6T ONE WAYR6-1L ONE WAYR6-1RCW1-7DETOURM4-10L DETOURM4-10RBEGINROAD WORKNEXT X MILESG20-T ROADCLOSEDR11-2R11-3ROAD CLOSEDAHEADLOCAL TRAFFIC ONLYROAD CLOSEDTOTHRU TRAFFICR11-4****RIGHT LANE MUST EXITR3-33RLEFT LANE MUST EXITR3-33L ONLYONLYSTOPHERE ONRED ONLY ONLY ONLY ONLY ONLY ONLYONLY Navigator LOOSEGRAVELCW8-7 FRESHOILCW21-2 TURNLANECLOSEDAHEADCW20-5DT CENTERLANECLOSEDAHEADCW20-5DC CW28-1T POWER LINESCW23-2 NEWTRAFFICPATTERNAHEADUTILITYWORKAHEADCW21-7D ONLY ONLY ONLY ONLY ONLY ONLY ONLY ONLY ONLY Navigator Type 3 Barricade Navigator Type 3 Barricade Type 1 Barricade Navigators Type 3 Barricade 2-Way Traffic Vertical Panel Type 3 Barricade Barrels Type 3 Barricade Barrels Type 3 Barricade 2-Way Traffic Vertical Panel Barrels Type 3 Barricade Type 1 Barricade Navigator Type 3 Barricade Type 2 Barricade Type 1 Barricade Barrels Type 3 Barricade Type 2 Barricade Type 1 Barricade Navigator Type 3 Barricade Type 2 Barricade Barrels Type 3 Barricade Type 2 Barricade ONLY ROAD CLOSED TO THRU TRAFFIC TYPE III R11-2 ROAD CLOSED ROAD CLOSED TO THRU TRAFFIC ROAD CLOSED TYPE III R11-2 / CW1-7 ROAD CLOSED DETOUR TYPE III R11-2 / M4-10R ROAD CLOSED DETOUR TYPE III R11-2 / M4-10L DETOUR TYPE III R11-4 / M4-10R ROAD CLOSED TO THRU TRAFFIC DETOUR TYPE III R11-4 / M4-10L ROAD CLOSED TO THRU TRAFFIC DETOUR TYPE III R11-4 / M4-10L ROAD CLOSED TO THRU TRAFFIC DETOUR TYPE III R11-4 / M4-10R ROAD CLOSED TO THRU TRAFFIC ROAD CLOSED DETOUR TYPE III R11-2 / M4-10L ROAD CLOSED DETOUR TYPE III R11-2 / M4-10R ROAD CLOSED TO THRU TRAFFIC ROAD CLOSED TO THRU TRAFFIC ROAD CLOSED TYPE III R11-2 / CW1-7 TYPE III R11-2 ROAD CLOSED RAMP CLOSED ROAD CLOSED RAMP CLOSED ROAD CLOSED SIDEWALK CLOSED USE OTHER SIDE SIDEWALK CLOSED USE OTHER SIDE 100ft Taper 100ft Buffer WORK ZONE30WORK ZONE30WHEN WORKERS ARE PRESENT WORK ZONETRAFFIC FINES DOUBLE WHEN WORKERS ARE PRESENT WORK ZONETRAFFIC FINES DOUBLE 90ft Shifting Taper 100ft 1000ft 1600ft 85ft SIDEWALK CLOSED 600ft Taper 280ft Buffer 180ft Taper 540ft Taper 660ft Taper 160ft 320ft 120ft Buffer 220ft Buffer 335ft Buffer 500ft 700ft485ft Buffer 900ft 600ft 800ft 585ft Buffer 840ft Taper 900ft Taper 720ft Buffer TALK OR TEXT LATERSTAY ALERTG20-10T STAY ALERTTALK OR TEXT LATERG20-10T M4-9SM4-9L M4-9RR3-2 PR8-3R5-2R3-4R3-1 R3-2R3-1 PR8-3R5-2R3-4G20-1bL NEXT MILESXXROAD WORK N EW S xxft Shoulder Taper xx 30 180 85 120 Speed Taper Buffer Sign Spacing 35 40 45 50 245 320 540 600 120 170 220 280 160 240 320 400 55 660 335 500 60 720 415 600 65 780 485 700 70 840 585 800 75 900 720 900 INTERSTATETEXAS** Devices spaced on 35ft centers Posted speed limit 45MPH Devices spaced on 25ft centers Posted speed limit 35MPH Devices spaced on 30ft centers Posted speed limit 40MP H Devices spaced on 40ft centers Posted speed limit 50MPH Devices spaced on 20ft centers Posted speed limit 30MPH Devices spaced on 45ft centers Posted speed limit 55MPH Devices spaced on 50ft centers Posted speed limit 60MPH Devices spaced on 55ft centers Posted speed limit 65MPH Devices spaced on 60ft centers Posted speed limit 70MPH Devices spaced on 65ft centers Posted speed limit 75MPH Devices spaced on 70ft centers Posted speed limit 80MPH KEEPRIGHT THIS PLAN IS FOR ILLUSTRATIVE PURPOSES ONLY AND IS NOT INTENDED TO RELIEVE THE CONTRACTOR FROM THE REQUIREMENTS SET FORTH BY RELATED CONTRACT DOCUMENTS, THE TEXAS MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) OR THE OVERALL RESPONSIBILITY TO TRAFFIC CONTROL SAFETY. All Traffic Control Plans (TCPs) are the property of Buyers Barricades, Inc. and are included with Buyers Barricades rental agreements. Traffic Control Plans issued without a rental agreement will be charged to the customer. Courtney Jeffus RIGHT LANEMUSTTURN RIGHTR3-7R Cole Benton MAPSCO: NOTE: Changes requested by Contractor do not conform to TXDOT/MUTCD standards. Buyers Barricades shall not be held responsible for results of deviation from standardized traffic/safety control. ONE WAYR6-1RONE WAYR6-1LONE WAY R6-1RONE WAY R6-1L ONE WAY R6-1R ONE WAY R6-1L ONE WAYR6-1R ONE WAYR6-1LCONSTRUCTIONENTRANCE**LEFT LANEMUSTTURN LEFTR3-7L Matt Sauer N E W S M4-9RM4-9L SIDEWALK CLOSED USE OTHER SIDE 1000ft 1/2 MILE 1 MILE RAMPCLOSEDAHEADCW20-3D NOTE: Plan design based on engineered stamped plans provided by Contractor does not conform to TXDOT/MUTCD standards. Buyers Barricades shall not be held responsible for results of deviation from standardized traffic/safety control. Type 2 Barricade Navigators Type 3 Barricade Water Barrier Type 1 Barricade Barrels Type 3 Barricade Water Barrier Navigators Type 3 Barricade Flagger w/Cones Barrels Type 3 Barricade Flagger w/Cones Dustin Rawlings NOTE: Plan requested by Contractor does not conform to TXDOT/MUTCD standards. Buyers Barricades shall not be held responsible for results of deviation from standardized traffic/safety control. SLOW ALLEYCLOSEDAHEAD ALLEY CLOSED TO THRU TRAFFIC ALLEY CLOSED TO THRU TRAFFIC TYPE III R11-2 ALLEY CLOSED TYPE III R11-2 ALLEY CLOSED 2RIGHT LANESCLOSED1/2 MILECW20-5aTR Jeremiah Keys 2LEFT LANESCLOSEDCW20-5aTL ROAD WORK AHEAD C W 2 0 - 1 D CW20-5R RIGHT LANE CLOSED ROAD WORK AHEAD C W 2 0 - 1 D CW20-5R RIGHT LANE CLOSEDEND ROAD WORK G20-2 END ROAD WORK G20-2 320ft Taper 170ft Buffer 240ft 290ft Work Zone Devices spaced on 30ft centers Posted speed limit 40MPH 240ft 240ft 240ft Arrow Board Christian Brown Navigator Type 3 Barricade SETUP ONLY BETWEEN 9AM - 3PM