Security Fire Systems-CS170502
Halie Hernandez
From:Matthew Mabry
Sent:Tuesday, May 02, 2017 2:09 PM
To:Halie Hernandez
Subject:SFS Traffic control plan Moss Utilities - Freeport Pkwy
Attachments:Freeport Pkwy (Freeport Pkwy & Sandy Lake Rd) RLC.PDF
Categories:This message has been archived by Retain on May 02 2017 17:31
Matthew Mabry
Engineering Construction Inspector
City of Coppell, TX
214-406-5223 (cell)
www.coppelltx.gov
From: Tommy White \[mailto:tommy@mossutilities.com\]
Sent: Tuesday, May 02, 2017 1:59 PM
To: Matthew Mabry <MMabry@coppelltx.gov>
Subject: Fwd: FW: Moss Utilities - Freeport Pkwy
Matt,
Here are the changes you requested. As soon as you have approval I can schedule everything to get the water
connection set up. Thanks!
---------- Forwarded message ----------
Christian Brown
From: <christian@buyersbarricades.com>
Date: Tue, May 2, 2017 at 1:54 PM
Subject: FW: Moss Utilities - Freeport Pkwy
To: Tommy White <tommy@mossutilities.com>
--
Thank You,
Tommy White
1
Superintendent
Mobile: 817-721-0290
Mail: tommy@mossutilities.com
Web: www.mossutilities.com
2
TCP DESIGNER
SALESMAN/EXECUTIVE NOTES
Phase 1 Sheet 1
Hamilton Duffy, PC
Consulting
Tex Reg F-5260
Chris Schreiner
Eddie Harmon
Jason Garrett
Marie Rhom
Michael Cooper
Kevin Omachel
Reedie Lea
CONTACT NUMBER:
Keith Hamilton
Lauren Simpson
Tony Troxclair
Jill Smith
Garrett White
Christian Brown
Right Lane Closure
CONTACT:
DATE:
CITY:
CONTRACTOR:
JOB NAME:
LOCATION:
SCOPE OF WORK:
Freeport Pkwy & Sandy Lake Rd
Freeport Pkwy
Coppell
Moss Utilities
Tommy White
85ft
Buffer120ft 245ft
Taper
320ft
Taper
170ft
Buffer240ft
400ft
415ft
Buffer
720ft
Taper
780ft
Taper
Lindsay Garrett
Jessica Paredes
Arrow
Board
MB
TMA
Type 1 Type 2 Type 3
817-721-0290
05/01/2017
Part A
Mike Moreno
50ft
Work
Zone
100ft
Work
Zone
150ft
Work
Zone
200ft
Work
Zone
250ft
Work
Zone
300ft
Work
Zone
350ft
Work
Zone
400ft
Work
Zone
450ft
Work
Zone
500ft
Work
Zone
1000ft
Work
Zone
1500ft
Work
Zone
ROADWORKAHEADCW20-1D CW20-5R RIGHTLANECLOSED CW20-5DL LEFTLANECLOSEDAHEAD RIGHTLANECLOSEDAHEADCW20-5DR TURNLANECLOSEDCW20-5T CENTERLANECLOSEDCW20-5C ROADCLOSEDAHEADCW20-3D DETOURAHEADCW20-2D ONE LANEROADAHEADCW20-4D BEPREPAREDTOSTOPCW3-4 CW20-7 LANE ENDSMERGERIGHTCW9-2TR LANE ENDSMERGELEFTCW9-2TL 2RIGHT LANESCLOSEDCW20-5aTR SHOULDERWORKCW21-5 ROADNARROWSCW5-1 TRUCKSENTERINGROADWAYCW27-1T CW3-2 CW4-3R CW4-3L CW21-1aT CW1-4L CW1-4R CW6-3 CW12-1 CW12-1 CW12-1 ENDROAD WORKG20-2ENDROAD WORKG20-2CW20-5LLEFTLANECLOSEDTOONCOMINGTRAFFICR1-2YIELDR1-2 APTOONCOMINGTRAFFICYIELDR1-2R1-2 AP STOPR1-1R5-1YIELDR1-2WRONGWAYR5-1aG20-1bR NEXT MILESXXROAD WORKNAMEADDRESSCITYSTATECONTRACTORG20-6T ONE WAYR6-1L ONE WAYR6-1RCW1-7DETOURM4-10L DETOURM4-10RBEGINROAD WORKNEXT X MILESG20-T ROADCLOSEDR11-2R11-3ROAD CLOSEDAHEADLOCAL TRAFFIC ONLYROAD CLOSEDTOTHRU TRAFFICR11-4****RIGHT LANE MUST EXITR3-33RLEFT LANE MUST EXITR3-33L ONLYONLYSTOPHERE ONRED
ONLY ONLY
ONLY ONLY ONLY ONLYONLY
Navigator
LOOSEGRAVELCW8-7 FRESHOILCW21-2 TURNLANECLOSEDAHEADCW20-5DT CENTERLANECLOSEDAHEADCW20-5DC CW28-1T POWER LINESCW23-2 NEWTRAFFICPATTERNAHEADUTILITYWORKAHEADCW21-7D
ONLY ONLY
ONLY
ONLY ONLY ONLY ONLY
ONLY ONLY
Navigator
Type 3 Barricade
Navigator
Type 3 Barricade
Type 1 Barricade
Navigators
Type 3 Barricade
2-Way Traffic
Vertical Panel
Type 3 Barricade
Barrels
Type 3 Barricade
Barrels
Type 3 Barricade
2-Way Traffic
Vertical Panel
Barrels
Type 3 Barricade
Type 1 Barricade
Navigator
Type 3 Barricade
Type 2 Barricade
Type 1 Barricade
Barrels
Type 3 Barricade
Type 2 Barricade
Type 1 Barricade
Navigator
Type 3 Barricade
Type 2 Barricade
Barrels
Type 3 Barricade
Type 2 Barricade
ONLY
ROAD CLOSED
TO
THRU TRAFFIC
TYPE III
R11-2
ROAD
CLOSED
ROAD CLOSED
TO
THRU TRAFFIC
ROAD
CLOSED
TYPE III
R11-2 / CW1-7
ROAD
CLOSED
DETOUR
TYPE III
R11-2 / M4-10R
ROAD
CLOSED
DETOUR
TYPE III
R11-2 / M4-10L
DETOUR
TYPE III
R11-4 / M4-10R
ROAD CLOSED
TO
THRU TRAFFIC
DETOUR
TYPE III
R11-4 / M4-10L
ROAD CLOSED
TO
THRU TRAFFIC
DETOUR
TYPE III
R11-4 / M4-10L
ROAD CLOSED
TO
THRU TRAFFIC
DETOUR
TYPE III
R11-4 / M4-10R
ROAD CLOSED
TO
THRU TRAFFIC
ROAD
CLOSED
DETOUR
TYPE III
R11-2 / M4-10L
ROAD
CLOSED
DETOUR
TYPE III
R11-2 / M4-10R
ROAD CLOSED
TO
THRU TRAFFIC
ROAD CLOSED
TO
THRU TRAFFIC
ROAD
CLOSED
TYPE III
R11-2 / CW1-7
TYPE III
R11-2
ROAD
CLOSED
RAMP
CLOSED
ROAD
CLOSED
RAMP
CLOSED
ROAD
CLOSED
SIDEWALK CLOSED
USE OTHER SIDE
SIDEWALK CLOSED
USE OTHER SIDE
100ft
Taper
100ft
Buffer
WORK ZONE30WORK ZONE30WHEN WORKERS ARE PRESENT WORK ZONETRAFFIC FINES DOUBLE WHEN WORKERS ARE PRESENT WORK ZONETRAFFIC FINES DOUBLE
90ft
Shifting
Taper 100ft
1000ft 1600ft
85ft
SIDEWALK
CLOSED
600ft
Taper
280ft
Buffer
180ft
Taper
540ft
Taper
660ft
Taper
160ft
320ft
120ft
Buffer
220ft
Buffer
335ft
Buffer 500ft
700ft485ft
Buffer
900ft
600ft
800ft 585ft
Buffer
840ft
Taper
900ft
Taper
720ft
Buffer
TALK OR TEXT LATERSTAY ALERTG20-10T STAY ALERTTALK OR TEXT LATERG20-10T M4-9SM4-9L M4-9RR3-2 PR8-3R5-2R3-4R3-1 R3-2R3-1 PR8-3R5-2R3-4G20-1bL NEXT MILESXXROAD WORK
N
EW
S
xxft
Shoulder
Taper
xx
30 180 85 120
Speed Taper Buffer Sign
Spacing
35
40
45
50
245
320
540
600
120
170
220
280
160
240
320
400
55 660 335 500
60 720 415 600
65 780 485 700
70 840 585 800
75 900 720 900
INTERSTATETEXAS**
Devices spaced on 35ft centers
Posted speed limit 45MPH
Devices spaced on 25ft centers
Posted speed limit 35MPH
Devices spaced on 30ft centers
Posted speed limit 40MP H
Devices spaced on 40ft centers
Posted speed limit 50MPH
Devices spaced on 20ft centers
Posted speed limit 30MPH
Devices spaced on 45ft centers
Posted speed limit 55MPH
Devices spaced on 50ft centers
Posted speed limit 60MPH
Devices spaced on 55ft centers
Posted speed limit 65MPH
Devices spaced on 60ft centers
Posted speed limit 70MPH
Devices spaced on 65ft centers
Posted speed limit 75MPH
Devices spaced on 70ft centers
Posted speed limit 80MPH
KEEPRIGHT
THIS PLAN IS FOR ILLUSTRATIVE PURPOSES ONLY AND
IS NOT INTENDED TO RELIEVE THE CONTRACTOR FROM
THE REQUIREMENTS SET FORTH BY RELATED CONTRACT
DOCUMENTS, THE TEXAS MANUAL ON UNIFORM TRAFFIC
CONTROL DEVICES (MUTCD) OR THE OVERALL
RESPONSIBILITY TO TRAFFIC CONTROL SAFETY.
All Traffic Control Plans (TCPs) are the property of Buyers
Barricades, Inc. and are included with Buyers Barricades
rental agreements. Traffic Control Plans issued without a
rental agreement will be charged to the customer.
Courtney Jeffus
RIGHT LANEMUSTTURN RIGHTR3-7R
Cole Benton
MAPSCO:
NOTE: Changes requested by Contractor do not conform to TXDOT/MUTCD standards.
Buyers Barricades shall not be held responsible for results of deviation from standardized traffic/safety control.
ONE WAYR6-1RONE WAYR6-1LONE WAY R6-1RONE WAY R6-1L ONE WAY R6-1R ONE WAY R6-1L ONE WAYR6-1R ONE WAYR6-1LCONSTRUCTIONENTRANCE**LEFT LANEMUSTTURN LEFTR3-7L
Matt Sauer
N
E
W
S
M4-9RM4-9L
SIDEWALK CLOSED
USE OTHER SIDE
1000ft 1/2 MILE 1 MILE
RAMPCLOSEDAHEADCW20-3D
NOTE: Plan design based on engineered stamped plans provided by Contractor does not conform to TXDOT/MUTCD standards.
Buyers Barricades shall not be held responsible for results of deviation from standardized traffic/safety control.
Type 2 Barricade
Navigators
Type 3 Barricade
Water Barrier
Type 1 Barricade
Barrels
Type 3 Barricade
Water Barrier
Navigators
Type 3 Barricade
Flagger w/Cones
Barrels
Type 3 Barricade
Flagger w/Cones
Dustin Rawlings
NOTE: Plan requested by Contractor does not conform to TXDOT/MUTCD standards.
Buyers Barricades shall not be held responsible for results of deviation from standardized traffic/safety control.
SLOW ALLEYCLOSEDAHEAD
ALLEY CLOSED
TO
THRU TRAFFIC
ALLEY CLOSED
TO
THRU TRAFFIC
TYPE III
R11-2
ALLEY
CLOSED
TYPE III
R11-2
ALLEY
CLOSED
2RIGHT LANESCLOSED1/2 MILECW20-5aTR
Jeremiah Keys
2LEFT LANESCLOSEDCW20-5aTL
ROAD
WORK
AHEAD
C
W
2
0
-
1
D
CW20-5R
RIGHT
LANE
CLOSED
ROAD
WORK
AHEAD
C
W
2
0
-
1
D
CW20-5R
RIGHT
LANE
CLOSEDEND
ROAD WORK
G20-2
END
ROAD WORK
G20-2
320ft
Taper
170ft
Buffer
240ft 290ft
Work
Zone
Devices spaced on 30ft centers
Posted speed limit 40MPH
240ft 240ft 240ft
Arrow
Board
Christian Brown
Navigator
Type 3 Barricade
SETUP ONLY BETWEEN 9AM - 3PM