Kyra Court-LR160614 (2)Rone Engineerin
�r
8908 Ambassador Row, Dallas, Tx 75247
Texas Engineering Firm Registration, No
1572
Corporate Phone: (214)$3 .9745
Report of Moisture Density Relationship
Client: JRose Architects
Report No.: 14158102
2104 Cosmos Way
Project No.: 1520637
Argyle, TX 76226
Lime Treated Brown Clay
Classification:
Date of Service: 06/14/2016
Test Method:
Report Date: 06/17/2016
Project: Kyra
ASTM D698 Method -B
Coppell, Texas
Services: Obtain a sample of material from the jobsite, bring the sample back to the laboratory and perform a moisture density relationship test in
accordance with ASTM Standards.
PROJECT DATA
Contractor:
Test For:
Lime Treated Paving Subg lade
Material:
Lime Treated Brown Clay
Classification:
Lime Treated Paving Subgrade
Test Method:
ASTM D4318 Method -B
ASTM D698 Method -B
REPORT OF TEST
Maximum Dry Density, pcf: 1103.4 pcf
Optimum Moisture Content, %: 20.5 %
Liquid Limit: 31
Plastic Limit: 27
Plasticity Index: 4
% Passing #200:
Date Sampled: 06/14/2016
Material Preparation: Moist
Rammer Type: Mechanical
Sampled By: Fritch, James
Sample Location:
200' North of Approach to Beltline Road
Q
CD
CD
100% saturation line for SG = 2.7 Estimated
---------------- ---------------
---------------------
- -
------------- - --------
---------------------
/ -- ----------------------------
._____..........................
-------------------------------------
1S 16 1T 18 19 24 21 22 23 24
Moisture' Content, percent
Technician: James Fritch Rone Engineering
S'ee Report 14158011 for technician time
Report Distribution:
Orig: JRose Architects (Argyle, TX) Attn: Mr. Jason Rose
(1-ec copy)
1-ec Rone Engineering Project Managers Jason Creasy, CET bye
Attn: Mr. Jason Creasy, CET Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd
(KA/JC)
Page 1 of 1