Kyra Court-LR1610108908 Ambassador Row, Dallas, TX 75247
Rone Engineering Texas Engineering Firm Registration,No. F-1572
Corporate Phone: (214) 630-9745
Report of Concrete Core Compressive Strength
Client: JRose Architects
Report No.: 14168802
2104 Cosmos Way
Project No.: 1520637
Argyle, TX 76226
Date of Service: 10/10/2016
Age of Concrete: Unknown
Report Date: 10/26/2016
Project: Kyra
Curing:
Coppell, Texas
Core
Services: Obtain concrete core samples, measure, cut, cure, cap and test in accordance with applicable standards.
Length
PROJECT DATA
Strength:
Aggregate Size (in): 1" nominal
Length (in): Varies
Test Method: ASTM C-42
ASTM C-174
Concrete Use:
Paving
Placement Date:
Sawed
Date Tested:
10/15/2016
Age of Concrete: Unknown
Drill Directions:
Vertical Down
Curing:
5 day bagged
REPORT OF TESTS
Technician: Dickie Timmons Started: 10:30am Finished: 01:15pm Rone Engineering
Report Distribution: _
Orig: JRose Architects (Argyle, TX) Attn: Mr. Jason Rose
(1-ec copy) G
1-ec Rone Engineering Project Managers [
Attn: Mr. Jason Creasy, CET Jason Creasy, CET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
.(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(JC/JC)
Page 1 of 1
Cored
Sawed
Capped
Length/
Maximum
Compressive
Core
Length
Length
Length
Diameter
Area
Diam.
Load
Correction
Strength
ID
Core Location
(in)
(in)
(in)
(in)
(in')
Ratio
(lbs. force)
Factor
(psi)
1
368' from Beltline Approach
6.0
5.50
5.6
3.72
10.87
1.51
62,970
0.960
5,560
2
225' from Beltline Approach
6.6
5.70
5.8
3.72
10.87
1.56
49,000
0.965
4,350
3
128' from Beltline Approach
6.5
6.30
6.5
3.72
10.87
1.75
47,280
0.980
4,260
4
50' from Beltline Approach
6.0
5.00
5.2
3.72
10.87
1.40
54,950
0.948
4,790
Average
4,740
Technician: Dickie Timmons Started: 10:30am Finished: 01:15pm Rone Engineering
Report Distribution: _
Orig: JRose Architects (Argyle, TX) Attn: Mr. Jason Rose
(1-ec copy) G
1-ec Rone Engineering Project Managers [
Attn: Mr. Jason Creasy, CET Jason Creasy, CET
Project Manager
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality
.(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are
for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd.
(JC/JC)