Loading...
Kyra Court-LR1610108908 Ambassador Row, Dallas, TX 75247 Rone Engineering Texas Engineering Firm Registration,No. F-1572 Corporate Phone: (214) 630-9745 Report of Concrete Core Compressive Strength Client: JRose Architects Report No.: 14168802 2104 Cosmos Way Project No.: 1520637 Argyle, TX 76226 Date of Service: 10/10/2016 Age of Concrete: Unknown Report Date: 10/26/2016 Project: Kyra Curing: Coppell, Texas Core Services: Obtain concrete core samples, measure, cut, cure, cap and test in accordance with applicable standards. Length PROJECT DATA Strength: Aggregate Size (in): 1" nominal Length (in): Varies Test Method: ASTM C-42 ASTM C-174 Concrete Use: Paving Placement Date: Sawed Date Tested: 10/15/2016 Age of Concrete: Unknown Drill Directions: Vertical Down Curing: 5 day bagged REPORT OF TESTS Technician: Dickie Timmons Started: 10:30am Finished: 01:15pm Rone Engineering Report Distribution: _ Orig: JRose Architects (Argyle, TX) Attn: Mr. Jason Rose (1-ec copy) G 1-ec Rone Engineering Project Managers [ Attn: Mr. Jason Creasy, CET Jason Creasy, CET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality .(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (JC/JC) Page 1 of 1 Cored Sawed Capped Length/ Maximum Compressive Core Length Length Length Diameter Area Diam. Load Correction Strength ID Core Location (in) (in) (in) (in) (in') Ratio (lbs. force) Factor (psi) 1 368' from Beltline Approach 6.0 5.50 5.6 3.72 10.87 1.51 62,970 0.960 5,560 2 225' from Beltline Approach 6.6 5.70 5.8 3.72 10.87 1.56 49,000 0.965 4,350 3 128' from Beltline Approach 6.5 6.30 6.5 3.72 10.87 1.75 47,280 0.980 4,260 4 50' from Beltline Approach 6.0 5.00 5.2 3.72 10.87 1.40 54,950 0.948 4,790 Average 4,740 Technician: Dickie Timmons Started: 10:30am Finished: 01:15pm Rone Engineering Report Distribution: _ Orig: JRose Architects (Argyle, TX) Attn: Mr. Jason Rose (1-ec copy) G 1-ec Rone Engineering Project Managers [ Attn: Mr. Jason Creasy, CET Jason Creasy, CET Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality .(composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. (JC/JC) Page 1 of 1