Kyra Court-LR161221Rone Engineering 8908 Ambassador Row, Dallas, TX 75247 Texas Engineering Firm Registration, No F_1572 Corporate Phone: (214)411-9745 Report of Concrete Compressive Strength Test Client: JRose Architects Report No.: 14176146 2104 Cosmos Way Project No.: 1520637 Argyle, TX 76226 Date of Service: 12/21/2016 Report Date: 01/19/2017 Project: Kyra Coppell, Texas Services: Obtain samples of fresh concrete at the placement locations, perform required testing, cast compressive strength samples and bring samples back to the laboratory for curing and testing in accordance with applicable standards. Contractor: 01/18/2017 Concrete Supplier: Big D Plant: 01 Specification Requirements (psi) Type Strength: 4,000 psi @ 28 days Slump (in.): 3" - 5" Air (%): 0-3% Test Method: ASTM C-172 28 ASTM C-31 (except 10.1.2) 80,260 ASTM C-143 Type 4 ASTM C-231 ASTM C-1064 ASTM C-138 6,330 ASTM C-1231 1 5 OCTKA ('-4Q PROJECT DATA Mix Design I.D.: NA Placement Date: 12/21/2016 Weather Conditions: Cloudy Time Sampled: 05:00pm Temperature - Air: 61 OF Truck No: 134 Air Content: 3.0% Overall Placement Location: Front entrance approach of Kyra Sample Location: Southeast quadrant REPORT OF TESTS Batch time: 04:20pm Concrete: 63°F Ticket No: 2925 Unit Weight (pcf): NA Measured Sh p (inches) 5.0 5. Concrete Compressive Cylinder 4" x 8" 01/18/2017 Cylinder Maximum Compressive Marked Date Age Diameter Area Load Strength Fracture Set No. Tested (days) (in) (int) (lbs) (psi) Type 1 1 12/28/2016 7 4.00 12.57 61,690 4,910 Type 3 1 2 01/18/2017 28 4.00 12.57 77,610 6,180 Type:r4i' 1 3 01/18/2017 28 4.00 12.57 80,940 6,440 Type 2 1 4 01/18/2017 28 4.00 12.57 80,260 6,390 Type 4 Average 6,330 1 5 HOLD RF9 RM Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 4.4 Technician: Cameron Washington Started: 11:30am Finished: 05:45pm Rone Engineering Report Distribution: Orig: JRose Architects (Argyle, TX) Attn: Mr. Jason Rose (1-ec copy) 1-ec Rone Engineering Project Managers Attn: Mr. Jason Creasy, CET Jason Creasy, CET y' Project Manager LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd (KA/JC) Page 1 of 1