Fairfield Inn & Suites-170511
May 11, 2017
To: Northpoint Construction
Project: Fairfield Inn; Coppell, TX
The following mixture(s) are submitted in accordance with ACI 318 Chapter 5, proportioning on the basis of field
experience or trial mixtures;
Mixture Code Description Intended Use
4711 5SK/3000PSI W/AIR Sidewalks
Charley’s Concrete guarantee of strength per ASTM C94 is provided all field samples are in accordance with
ASTM C172 and ASTM C31 and laboratory testing complies with ASTM C39 and ASTM C1077. Charley’s
Concrete will guarantee the strength performance of the concrete mixtures submitted when placed with ambient
temperatures between 40 ̊F and 100 ̊F provided plastic properties are not exceeded and concrete is placed within 90
minutes of batch time. This temperature and time range does not supersede project specifications. All concrete
should be placed and cured in strict accordance with ACI guidelines for hot and cold weather concreting and may
require the addition of ice during hot weather placements (at the customer’s request). During cold weather
placements all concrete surfaces should be protected for a minimum of 24 hours to allow concrete to attain a
compressive strength of 500 psi.
ACI 304.2R “Placing Concrete by Pumping Methods” states that the inside diameter of the hose should be a
minimum of 3 times the maximum aggregate size in the mixture. It is recommended to minimize or eliminate the
free fall of concrete to prevent segregation and to avoid the loss of air. Boom configurations may r equire
adjustments to the concrete mixture.
* Due to availability of materials namely natural concrete sand and fly ash, it may be necessary during the course of
this project to substitute a source of material. Substitutions will be in complete compliance with project
specifications and should not affect mixture characteristics or performance.
We appreciate the opportunity to be of service to your company. Please forward any engineer comments and
approvals to our office. We also request you add Charley’s Concrete to the distribution list for all laboratory
test results for review and to monitor performance and compliance with project requirements.
If you have any questions or comments regarding this matter feel free to contact our office at your convenien ce.
Charley's Concrete Co., Ltd.
PO Box 1106
Keller, TX 76244
Office - 817.431.2016
Fax - 817.431.5337
Date:5/11/2017
Contractor:Northpoint Construction
Project:Fairfield Inn
Project Location:1150 Northpoint, Coppell
Intended Use:Sidewalks
Mix Design:4711
Mix Specifications Min 28 Days
Strength:3000 psi
Fly Ash 0%
Slump:4" +/- 1"
Air:5% +/- 1%
Other:
Material Type Source Abs Volume
Cement ASTM C-150 TYPE I 470 lb/yd3 Texas Lehigh 2.39
Fly Ash ASTM C-618 TYPE F lb/yd3 Fly Ash Direct 0.00
Coarse Aggregate - 1"ASTM C-33 #57 1850 lb/yd3 Hanson 11.06
Coarse Aggregate - ASTM C-33 #lb/yd3 0.00
Peagravel ASTM C-33 #8 lb/yd3 0.00
Fine Aggregate ASTM C-33 1365 lb/yd3 Trinity 8.32
Admixture-Sika 686 ASTM C-494 TYPE A & F 6 oz/cwt Sika
Admixture-SikaTard 440 ASTM C-494 TYPE B & D 0-4 oz/cwt Sika
Admixture - Sika Air ASTM C-260 0.65 oz/cwt Sika 1.22
Water/Cement Ratio 0.53 250 lb/yd3 4.01
152.6 lbs/ft3 Air-free Density 27.00
Basis for Mix Design Laboratory Mix
(Check One)Historical Mix
* ASTM C94 Standard Specification for Ready-mixed Concrete states "When the concrete strength is used as a basis
for acceptance the manufacturer shall be entitled to copies of test reports."
** Any water added to this concrete resulting in excess of specified slump or water/cement ratio can result in strength
loss and concrete damage and is at the customer's risk
Please send reports to the address listed above or email to tanya@charleysconcrete.com
Charley's Concrete
Weights SSD
Charley's Concrete Co., Ltd.
Contractor:various
Job:various
Lab:various
Mix No.:4711 Standard Deviation:544
Strength:3000 psi Average Strength:4689
Agg. Size:1"No. test 30
ACI 318-11 Required average strength.
(1)3729 psi
(2)3767 psi
28 Day 3 Consecutive
Date Temp.Slump Air %7 Day 28 Day 28 Day Average Average
1/5/2016 56 4 4.4 3660 4810 4900 4855 4558
1/31/2016 60 3.75 4.1 4130 5260 5060 5160 4907
2/9/2016 60 6 3.5 2270 3770 3880 3825 4613
2/9/2016 58 5.75 3.4 3020 4030 4110 4070 4352
2/9/2016 56 5.5 3.2 3490 4330 4430 4380 4092
2/9/2016 58 5.5 3.4 3690 4640 4490 4565 4338
2/15/2016 63 4.5 4.2 3730 4910 4930 4920 4622
2/15/2016 63 4.25 4.8 3860 4690 4730 4710 4732
2/16/2016 64 4.5 3 4590 5850 5790 5820 5150
2/16/2016 63 6 4 3360 4410 4370 4390 4973
2/16/2016 61 5.5 4 3010 4100 4240 4170 4793
2/19/2016 73 4.75 3.1 5520 6260 6260 6260 4940
2/19/2016 71 4.5 3 4640 5220 5310 5265 5232
2/19/2016 71 4.5 4 3880 4360 4690 4525 5350
3/2/2016 64 3 4 3860 4830 4770 4800 4863
3/2/2016 60 4.5 4.2 3790 4810 4700 4755 4693
3/2/2016 59 5 4.4 3130 4280 4220 4250 4602
4/8/2016 82 5 4.3 4110 5220 5240 5230 4745
4/10/2016 82 5 3 3510 4510 4340 4425 4635
4/15/2016 78 5 3.7 3490 4740 4710 4725 4793
4/28/2016 66 5 3.5 2900 4190 4300 4245 4465
4/28/2016 65 5.5 3.6 2700 4300 4010 4155 4375
4/28/2016 66 6 3.5 3390 4540 4600 4570 4323
4/28/2016 67 5.5 3.3 3620 4270 4260 4265 4330
5/31/2016 78 4.5 3.6 3760 4580 4760 4670 4502
9/15/2016 85 5 4.6 4330 5210 5180 5195 4710
9/15/2016 86 5 4 3760 4950 4830 4890 4918
9/25/2016 90 5 3.9 3210 4040 4140 4090 4725
10/1/2016 85 4.25 4 4090 5320 5300 5310 4763
10/29/2016 76 5.25 5.2 3340 4140 4190 4165 4522
Plant:I
Report Date:04/11/17
Buda, Texas, 78610 Production Period:Star 03/01/17
Contact:Victor Gonzalez Ends 03/31/17
Phone:(512) 295-9241 Tracking No.TLCBU 0000010
Fax.(512) 295-2431
6.0 max.1.4 Air content of mortar (volume %)ASTM C-185 12 max
3.5 max. E 3.4 Blaine fineness (m2/kg)ASTM C-204 260 min.
3.5 max.2.2 Mesh 325 (45 microns) % through ASTM C-430 A - B
Insoluble Residue (%) 1.5 max.0.53 Autoclave expansion (%)ASTM C-151 0.80 max.
CO2 (%)A 1.29
Limestone (%)5.0 max.3.2 Initial - Not less than or More than ASTM C - 191 45 - 375
CaCO3 in Limestone (%)70 min 80.7 Final ASTM C - 191 A
Total Alkali as Na2O (OPTIONAL)A 0.79
Minimum 0.76 1 day, Minimum MPa (psi)ASTM C-109 A - B 17.8 (2580)
Maximum 0.82 3 day, Minimum MPa (psi)ASTM C-109 12 (1740)28.8 (4180)
7 day, Minimum MPa (psi)ASTM C -109 19 (2760)35.3 (5120)
28 day, Minimum MPa (psi) (OPTIONAL)ASTM C-109 A - B - D 41.3 (5990)
False Set (OPTIONAL)ASTM - C451 50 min.
Mortar Expansion Bars ASTM C-1038 0.020% Max E
Type Slag Limestone
% Addition 5% Max 0.0 3.2 ASTM C - 150 Annex A1
SiO2(%)A 39.88 10.47 C3S A 58 C3S 60
Al2O3(%)A 9.37 2.86 C2S A 14 C2S 15
Fe2O3(%)A 5.05 0.95 C3A 8 max 11 C3A 12
CaO (%)A 28.75 46.90 C4AF A 6 C4AF 6
SO3(%)A 1.81 1.86 C3S + 4.75 x C3A A 113 ----- -----
A Not Applicable
B Limit not specified by purchaser. Test result provided for information only.
C Adjusted (ASTM Annex A, point A 1.6)
D Test Result of prior Month
E ASTM C-150 Table 1 Note D permits to exceed SO3 content provided it has been demonstrated to meet what is established under the Test Method ASTM C-1038 at 14 days
QC Manager:V Gonzalez-Torres
Potential Compounds (%) C
Finished cement Base cement
We certify that the above described cement, at the time of shipment, meets the chemical and physical requirements of the current applicable specifications ASTM C150 and AASHTO M85. Cement analysis are reported
as oxides, in accordance with ASTM Test Method C114. Silicon dioxide (SiO2) is present in the combined state as the compounds Tricalcium silicate and dicalcium silicate, and not crystalline silica. The above data
represents the average of mill samples from the production stream. Inorganic processing additions have been interground in accordance with ASTM C-465. The average composition of this processing addition can be
found listed above. Compliance documents for this processing addition are available upon request. We are not responsible for improper use or workmanship.
A
Inorganic processing additions & Limestone
Compressive strength
100
200
9
368
94.1
74
0.05
701 Cement Plant Road
MILL TEST REPORT
Chemical analysis % - ASTM C-114 Physical Test ASTM C-150
Item Spec.
Limit
Test
Results Item Spec.
Limit
Test
Result
MgO (%)
Time of setting - Vicat test (minutes)
SO3(%)
Loss on Ignition (%)
TEXAS LEHIGH CEMENT Co. LP
P.O. Box 610 Buda, Texas 78610
Sales (512) 295-6111 Customer Service (800) 252 - 5408
Buda Cement Type:
AASHTO ACREDITED
Trinity Materials Laboratory Testing
This material (Paradise-1390) was sampled under ASTM D-75 on 04/05/17.
The sample was reduced under ASTM C-702.
This test was performed under ASTM C-136, C-29, C-128, & D-2419.
This product from Trinity Materials is in tolerance according to ASTM C-33.
Summary of Results:
Concrete Sand
Sieve
Size
Weight
Retained
Percent
Retained
Percent
Passing
Specifications %
Passing
#4 7.6 0.9 99.1 95-100
#8 124.6 14.2 85.8 80-100
#16 387.9 44.3 55.7 50-85
#30 405.7 46.4 53.6 25-60
#50 624.5 71.4 28.6 5-30
#100 841.6 96.2 3.8 0-10
#200 869.8 99.4 0.6 0-3
Pan 875.0 100.0 0.0
___________________________________________________________
F.M. = 2.73
Sand Equivalency = 88.3 % Specific Gravity = 2.53
Unit Weight = 112.0 lbs pcf Absorption = 1.3 %
Sincerely,
Quality Control Manager
Trinity Materials Inc.
04/11/17
ConstructionSikament® 686
High Range and Mid Range Water Reducing Admixture
Description Sikament 686 is a high range water reducing admixture utilizing Sika’s Visco-
Crete Technology. It’s unique formulation is based on polycarboxylate
technology.
Sikament 686 meets the requirements for ASTM C-494 Types A and F.
Applications Sikament 686 is recommended for use in the production of all high strength
concrete products, whenever high plasticity and increased early and ultimate
strengths are desired.
The superplasticizing action of Sikament 686 provides excellent workability at
low water cement ratios.
Advantages High Range Water Reducing Applications: When used as a high range wa-
ter reducing admixture, water reduction up to 30% can be obtained. The su-
perplasticizing action allows for the production of high slump flowing concrete
with excellent workability that can be placed with minimum vibration even at
a low water/cement ratio. The dispersing action of Sikament 686 maximizes
cement hydration efficiency and improves concrete’s early and long term com-
pressive strengths.
Mid Range Water Reducing Applications: At a lower dosage, Sikament 686
can be used as a cost effective mid range water reducing admixture or simply
as a water reducing admixture for production of conventional slump concrete.
When used as a mid range water reducing admixture, water reduction up to
15% can be obtained. This application is ideal for use with lean, harsh con-
crete mixes or concrete containing flyash. Sikament 686 will improve
workability and finishability.
The combined water reducing and superplasticizing action provide the follow-
ing benefits:
n Higher early and ultimate strengths for cost effective high strength con-
crete and earlier structural use of concrete.
n Higher early strengths allow faster demolding and more efficient use of
forms to precast producers.
n Increased slump improves workability and reduces labor costs.
n Full flow action aids in pumping and reduces need for vibration.
n Greater concrete density reduces permeability and increases durability.
Sikament 686 does not contain calcium chloride or any other intentionally
added chlorides and will not initiate or contribute to corrosion on steel rein-
forcement present in the concrete.
How to Use
Dosage Dosage rates will vary depending on the material used, ambient conditions
and the requirements of a specific project.
For general concreting applications, Sika recommends a dosage rate between
3-12 fl. oz. /100 lbs. (195-780 ml/100 kg) cementitious materials. If maximum
water reduction is required, dosage up to 18 fl.oz./100 lbs. (1170 ml/100 kg) of
cementitious materials may be used. In this case, delayed setting times may
occur. Dosage rates outside the recommended range may be used where
specialized materials such as microsilica are specified, extreme ambient
conditions are encountered or unusual project conditions require special con-
sideration. In this case please contact your local regional Sika office or Sika
technical service department at 1-800-933-7452 for further information.
Mixing For best plasticizing results, Sikament 686 should be added directly
to freshly mixed concrete in the concrete mixer at the end of the batching
cycle.
Product Data Sheet
Edition 12.2005
Identification no. 180-540
Sikament 686
ConstructionKEEP CONTAINER TIGHTLY CLOSED • KEEP OUT OF REACH OF CHILDREN • NOT FOR INTERNAL CONSUMPTION • FOR INDUSTRIAL USE ONLY
All information provided by Sika Corporation (“Sika”) concerning Sika products, including but not limited to, any recommendations and advice
relating to the application and use of Sika products, is given in good faith based on Sika’s current experience and knowledge of its products
when properly stored, handled and applied under normal conditions in accordance with Sika’s instructions. In practice, the differences in materi-
als, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika’s control are such that Sika assumes no
liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be
created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s).
Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at www.sikacorp.com or by calling 800-933-7452.
Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product’s most cur-rent Technical Data Sheet, product label and Material Safety Data Sheet which are available at www.sikaconstruction.com or
800-933-7452. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction
for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use.
SIKA warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties
on the current Technical Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and
assumes all risks. Buyer’s sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor.
NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTIBILITY
OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR
SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN
A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS.
Sika Canada Inc.
601, Delmar Avenue
Pointe-Claire, QC H9R 4A9
Phone: (514) 697-2610
Fax: (514) 697-3087
www.sika.ca
Sika Corporation
201 Polito Avenue
Lyndhurst, NJ 07071
Phone: (201) 933-8800
Fax: (201) 933-6225
www.sikaconstruction.com
1-800-933-SIKA
Regional Information and Sales Centers. For the location of your nearest Sika representative, contact your regional center.
U.S. : North East Region: Fairless Hills, PA, Phone: (215) 295 -6600 North Central Region: Marion, OH, Phone: (800) 851-1545
South East Region: Conyers, GA, Phone: (770) 760-1300 South Central Region: Mesquite, TX, Phone: (972) 289-6480
Western Region: Santa Fe Springs, CA, Phone: (562) 903-3650
Canada: Ontario: Mississauga, ON, Phone: (905) 795-3177, Alberta: Edmonton, AB, Phone: (780) 486-6111
Quality Certification Numbers: Lyndhurst: FM 69711 (ISO 9000), FM 70421 (QS 9000), Marion: FM 69715, Kansas City: FM 69107, Santa Fe Springs: FM 69408
Sikament 686 may also be dispensed as an integral material during the regu-
lar admixture batching cycle, or into freshly mixed concrete in a Ready-Mix
truck at the concrete plant or job site.
To optimize the superplasticizing effect, Sika recommends that the combined
materials be mixed for 80-100 revolutions, either in the concrete mixer or in
the Ready-Mix truck.
Combination with other Admixtures: Sikament 686 is highly effective as a
single admixture or in combination with other admixtures in the Sika System.
If used in combination with certain Sikament high range water reducers, it
may affect the plastic properties of fresh concrete. Please contact your local
regional office or technical service department at 1-800-933-7452 for further
information.
Combination with Microsilica: Sikament 686 is particularly well suited for
use with Microsilica because of its water reduction capability.
Packaging Sikament 686 is available in 55 gallon drum (208 liter), 275 gallon totes
(1040 liters) and bulk delivery.
Storage and Shelf Life Sikament 686 should be stored at above 40°F (5°C). If frozen, thaw and agi-
tate thoroughly to return to normal state. Protect from direct sunlight.
Shelf life when stored in dry warehouse conditions between 40°F and 80°F
(5°C - 27°C) is one year.
Typical Data
Appearance Brown liquid.
Specific Gravity Approx. 1.1
CAUTion: iRRiTAnT Contains Aqueous Polymer Solution (CAS:Mixture), Triethanolamine (CAS:
102-71-6). May cause eye/skin/respiratory irritation. May be harmful if swallowed.
Handling and Storage Avoid direct contact. Wear personal protective equipment (chemical resistant
goggles/gloves/clothing) to prevent direct contact with skin and eyes. Use
only in well ventilated areas. Wash thoroughly with soap and water after use.
Remove contaminated clothing and launder before reuse.
First Aid Eyes: Hold eyelids apart and flush thoroughly with water for 15 minutes. Skin:
Remove contaminated clothing. Wash skin thoroughly for 15 minutes with
soap and water. inhalation: Remove to fresh air. ingestion: Do not induce
vomiting. Dilute with water. Contact physician. in all cases contact a physi-
cian immediately if symptoms persist.
Clean Up Use personal protective equipment (chemical resistant goggles/gloves/cloth-
ing). Without direct contact, remove spilled or excess product and place in
suitable sealed container. Dispose of excess product and container in accor-
dance with applicable environmental regulations.
Sika and Sikament are registered trademarks. Made in USA. Printed in USA.
ConcretePRIOR TO EACH USE OF ANY SIKA PRODUCT, THE USER MUST ALWAYS READ AND FOLLOW THE WARNINGS AND
INSTRUCTIONS ON THE PRODUCT’S MOST CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA
SHEET WHICH ARE AVAILABLE ONLINE AT HTTP://USA.SIKA.COM/ OR BY CALLING SIKA'S TECHNICAL SERVICE
DEPARTMENT AT 800-933-7452. NOTHING CONTAINED IN ANY SIKA MATERIALS RELIEVES THE USER OF THE
OBLIGATION TO READ AND FOLLOW THE WARNINGS AND INSTRUCTION FOR EACH SIKA PRODUCT AS SET FORTH
IN THE CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET PRIOR TO PRODUCT USE.
SikaTard® 440
Hydration Controlling Admixture
Description SikaTard® 440 is a hydration controlling admixture to control the hydration of cement.
The use of SikaTard® 440 allows the concrete producer to stabilize concrete mixes for
long periods without negatively affecting concrete durability. SikaTard® 440 can also
be used stabilize returned concrete and re-use it. SikaTard® 440 can also be used in
concrete wash water application. SikaTard® 440 meets the requirements of ASTM
C-494, Type B and Type D admixture.
Applications Typical Applications:
■ Transport freshly batched ready mix concrete for long distances.
■ For better control of concrete set time in hot and cold weather concreting
applications.
■ Large concrete pours; to help prevent cold joints.
■ Pumping long distances
■ Low water cement ratio concrete, such as high strength or pervious concrete.
■ High early strength concrete for improvement of workable life without a
detrimental effect on early strengths.
■ Utilize returned concrete and wash water applications.
■ Pervious concrete application.
■ Stabilize shotcrete mixes
■ Whenever controlled set time or cement hydration is required.
Benefits ■ Increases workable life of concrete up to several hours.
■ Allows controlled delay in set time.
■ Provides flexibility in planning and scheduling concrete pours.
■ Allows returned concrete to be re-used.
■ When used in wash water application, prevents concrete producers from having to
clean the truck at the end of day’s work and saves water.
■ The effect of SikaTard® 440 in concrete can be negated by addition of appropriate
accelerators, at any time.
Product Data Sheet
Edition 10.10.2014
SikaTard® 440
Sika Canada Inc.
601, Delmar Avenue
Pointe-Claire, QC H9R 4A9
Phone: (514) 697-2610
Fax: (514) 697-3087
can.sika.com
Sika Corporation
201 Polito Avenue
Lyndhurst, NJ 07071
Phone: (201) 933-8800
Fax: (201) 933-6225
usa.sika.com
Regional Information and Sales Centers. For the location of your nearest Sika representative, contact your regional center.
U.S. : Northeast: Fairless Hills, PA, Phone: (215) 295-6600 North Central: Ottawa, IL 61350, Phone: (815) 431-1080
South East: Conyers, GA, Phone: (770) 760-1300 South Central: Mesquite, TX, Phone: (972) 289-6480
Western Region: Santa Fe Springs, CA, Phone: (972) 289-6480
Canada: Ontario: Mississauga, ON, Phone: (905) 795-3177 Alberta: Edmonton, AB, Phone: (780) 486-6111
Quality Certification Numbers: Lyndhurst: FM 69711 (ISO 9000), FM 70421 (QS 9000), Marion: FM 69715, Kansas City: FM 69107, Santa Fe Springs: FM 69408
KEEP CONTAINER TIGHTLY CLOSED • KEEP OUT OF REACH OF CHILDREN • NOT FOR INTERNAL CONSUMPTION • FOR INDUSTRIAL USE ONLY •
FOR PROFESSIONAL USE ONLY
All information provided by Sika Corporation (“Sika”) concerning Sika products, including but not limited to, any recommendations and advice
relating to the application and use of Sika products, is given in good faith based on Sika’s current experience and knowledge of its products
when properly stored, handled and applied under normal conditions in accordance with Sika’s instructions. In practice, the differences
in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika’s control are such that
Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall
any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its
products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding
with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika
product(s) are subject to its current terms and conditions of sale which are available at http://usa.sika.com/ or by calling 800-933-7452.
Sika warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties
on the current Product Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and
assumes all risks. Buyer’s sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor.
NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE
FOR THE USE OF THIS PRODUCT IN A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS.ConcretePRIOR TO EACH USE OF ANY SIKA PRODUCT, THE USER MUST ALWAYS READ AND FOLLOW THE WARNINGS AND
INSTRUCTIONS ON THE PRODUCT’S MOST CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA
SHEET WHICH ARE AVAILABLE ONLINE AT HTTP://USA.SIKA.COM/ OR BY CALLING SIKA'S TECHNICAL SERVICE
DEPARTMENT AT 800-933-7452. NOTHING CONTAINED IN ANY SIKA MATERIALS RELIEVES THE USER OF THE
OBLIGATION TO READ AND FOLLOW THE WARNINGS AND INSTRUCTION FOR EACH SIKA PRODUCT AS SET FORTH
IN THE CURRENT PRODUCT DATA SHEET, PRODUCT LABEL AND SAFETY DATA SHEET PRIOR TO PRODUCT USE.
How to Use
Dosage Dosage rates will vary according to materials used, ambient conditions, and the
requirements of a specific project. For normal applications, depending on retardation
required, the dosage of SikaTard® 440 will vary from 2-8 fl.oz. per 100 lbs. (130-520
ml / 100 kg) of cementitious mass. For stabilization for longer periods the dosage
can be increased up to 48 fl.oz. per 100 lbs. (3130 ml / 100 kg) of cementitious mass.
Concrete trial mixes must be conducted to determine the optimum dosage. For
more information about the use of this product please contact the local Sika sales
representative or the Technical Service Department at 1-800-933-7452.
Mixing Introduce SikaTard® 440 at a suitable time during the mixing process of concrete.
Preliminary trials on site should be conducted to determine the required dosage
rates. To optimize the stabilizing effect, after the addition of SikaTard® 440, Sika
recommends that the combined materials be mixed for 80-100 revolutions, either
in the concrete mixer or in the Ready-Mix truck.
Combination with Other Admixtures: SikaTard® 440 can be used in conjunction
with all Sigunit® accelerators. SikaTard® 440 is also compatible with all other Sika
admixtures.
Packaging SikaTard® 440 is available in 55 gallon drums (208 liters), 275 gallon totes (1040 liters)
and bulk delivery.
Storage and Shelf Life SikaTard® 440 should be stored at above 40°F (5°C). If frozen, thaw and agitate
thoroughly to return to normal state.
Shelf life when stored in dry warehouse conditions between 50°F and 80°F
(10°C - 27°C) is 1 year. Protect from direct sun and freezing temperatures.
Typical Data
Appearance Green Liquid
Specific Gravity Approx. 1.152
ConstructionSika® Air
Air Entraining Admixture
Description Sika Air admixture is an aqueous solution of organic materials.
Sika Air meets the requirements of ASTM C-260 for air entraining admixtures.
Applications Sika Air is recommended for use whenever air entrained concrete is desired.
Ready-mix, precast and block producers can achieve predictable and uniform
entrained air contents in concrete, even where harsh lean mixes are used or
fly-ash is added to the concrete.
Advantages Durability:
Air entrainment is recognized as the most effective prevention against con-
crete scaling in exposed environments. Air entrained concrete delivers par-
ticular benefits in the form of increased concrete durability. This is important
in colder climates where frost and freeze-thaw cycles can cause scaling and
damage to the concrete surface.
Air entraining agents help to prevent scaling by creating microscopic air
voids that water trapped in the concrete can expand into when the concrete
freezes, thus preventing cracks caused by the natural expansion. Entrained
air voids in the concrete will also increase durability in harsh environments
where concrete is exposed to deicing salts, marine salts and sulfates.
Workability and Placeability:
Workability and placeability are also improved by the lubricating action of the
microscopic bubbles in the concrete. Concrete will flow better, and bleeding
and shrinkage will be reduced because less water is needed to obtain the
desired workability.
How to Use
Dosage Dosage rates for Sika Air will typically fall between 0.5 and 3 fl. oz. per 100
lbs. (32 - 195 ml/100 kg) of cementitious to entrain between 4 and 6 percent
air. Higher air contents may be obtained by increasing the dosage rate.
Dosage rates will vary depending on the air content required for a particular
project. Typically air contents will be specified in the range of 4 to 8 percent by
volume.
Other factors that may affect the amount of air entrained into the concrete
including total cementitious content, type of pozzolanic materials, sand grada-
tion, salt/clay in aggregates, temperature and water content. The use of fly
ash, particularly high LOI fly ash, can result in a higher dosage of air entrain-
ment. Sika recommends that trial mixes be performed whenever material or
any other changes are made that may affect the amount of entrained air.
In mixes requiring a lower or higher amount dosage rate, please contact your
local regional Sika office or Sika technical service department at 1-800-933-
7452 for further information.
Product Data Sheet
Edition 09.25.2009
Identification no. 147-540
Sika Air
ConstructionKEEP CONTAINER TIGHTLY CLOSED • KEEP OUT OF REACH OF CHILDREN • NOT FOR INTERNAL CONSUMPTION • FOR INDUSTRIAL USE ONLY
All information provided by Sika Corporation (“Sika”) concerning Sika products, including but not limited to, any recommendations and advice
relating to the application and use of Sika products, is given in good faith based on Sika’s current experience and knowledge of its products
when properly stored, handled and applied under normal conditions in accordance with Sika’s instructions. In practice, the differences in materi-
als, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika’s control are such that Sika assumes no
liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be
created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika
product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s).
Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s)
are subject to its current terms and conditions of sale which are available at www.sikacorp.com or by calling 800-933-7452.
Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product’s most cur-
rent Technical Data Sheet, product label and Material Safety Data Sheet which are available at www.sikaconstruction.com or
800-933-7452. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use.
SIKA warrants this product for one year from date of installation to be free from manufacturing defects and to meet the technical properties
on the current Technical Data Sheet if used as directed within shelf life. User determines suitability of product for intended use and
assumes all risks. Buyer’s sole remedy shall be limited to the purchase price or replacement of product exclusive of labor or cost of labor.
NO OTHER WARRANTIES EXPRESS OR IMPLIED SHALL APPLY INCLUDING ANY WARRANTY OF MERCHANTIBILITY
OR FITNESS FOR A PARTICULAR PURPOSE. SIKA SHALL NOT BE LIABLE UNDER ANY LEGAL THEORY FOR
SPECIAL OR CONSEQUENTIAL DAMAGES. SIKA SHALL NOT BE RESPONSIBLE FOR THE USE OF THIS PRODUCT IN
A MANNER TO INFRINGE ON ANY PATENT OR ANY OTHER INTELLECTUAL PROPERTY RIGHTS HELD BY OTHERS.
Sika Canada Inc.
601, Delmar Avenue
Pointe-Claire, QC H9R 4A9
Phone: (514) 697-2610
Fax: (514) 697-3087
www.sika.ca
Sika Corporation
201 Polito Avenue
Lyndhurst, NJ 07071
Phone: (201) 933-8800
Fax: (201) 933-6225
www.sikaconstruction.com
1-800-933-SIKA
Regional Information and Sales Centers. For the location of your nearest Sika representative, contact your regional center.
U.S. : North East Region: Fairless Hills, PA, Phone: (215) 295 -6600 North Central Region: Marion, OH, Phone: (800) 851-1545
South East Region: Conyers, GA, Phone: (770) 760-1300 South Central Region: Mesquite, TX, Phone: (972) 289-6480
Western Region: Santa Fe Springs, CA, Phone: (562) 903-3650
Canada: Ontario: Mississauga, ON, Phone: (905) 795-3177, Alberta: Edmonton, AB, Phone: (780) 486-6111
Quality Certification Numbers: Lyndhurst: FM 69711 (ISO 9000), FM 70421 (QS 9000), Marion: FM 69715, Kansas City: FM 69107, Santa Fe Springs: FM 69408
Mixing Measure the required quantity per batch manually or with automatic dispenser
equipment. Add Sika Air to mixing water or sand. Do not mix with dry cement.
When Sika Air is used in combination with other admixtures, care must be
taken to dispense each admixture separately into the mix.
Combination with Other Admixtures:
Combination with other admixtures, particularly water reducers and retarders, may
increase the amount of entrained air in the mix. Air contents should be checked with
an air-meter after batching and dosage adjustments made at the concrete plant.
Packaging Sika Air is available in 55 gallon drum (208 liter), 275 gallon totes (1040 liters)
drums and bulk delivery.
Storage and Shelf life Sika Air should be stored at above 40°F (5°C). If frozen, thaw and agitate
thoroughly to return to normal state.
Shelf life when stored in dry warehouse conditions between 50°F and 80°F
(10°C - 27°C) is one year.
Typical Data
Appearance Dark Amber liquid.
Specific Gravity Approx. 1.0
CAUTiOn: irriTAnT Contains Aqueous Solution (CAS:Mixture). May cause eye/skin/respiratory
irritaton. May be harmful if swallowed.
Handling and Storage Avoid direct contact. Wear personal protective equipment (chemical resistant
goggles/gloves/clothing) to prevent direct contact with skin and eyes. Use
only in well ventilated areas. Wash thoroughly with soap and water after use.
Remove contaminated clothing and launder before reuse.
First Aid Eyes: Hold eyelids apart and flush thoroughly with water for 15 minutes. Skin:
Remove contaminated clothing. Wash skin thoroughly for 15 minutes with
soap and water. inhalation: Remove person to fresh air. ingestion: Do not
induce vomiting. Dilute with water. Contact physician. in all cases contact a
physician immediately if symptoms persist.
Safety Tested and Certified by WQA according to NSF/ANSI 61 Section 5 for
materials safety.
Clean Up Use personal protective equipment (chemical resistant goggles/gloves/cloth-
ing). Without direct contact, remove spilled or excess product and place in
suitable sealed container. Dispose of excess product and container in accor-
dance with applicable environmental regulations.
Sika is a registered trademark. Made in USA. Printed in USA.
MATERIAL SAFETY DATA SHEET
Charley’s Concrete
PO. Box 1106
Keller, TX 76244
817-431-2016
IDENTIFIC ATION
Previous MSDS:
This MSDS supersedes all previous versions.
Revision Date:
09-14-11
Chemical Name/Synonyms:
Ready-Mix Concrete, Freshly Mixed Unhardened
Concrete .
Chemical F amily:
Calcium compounds
Silica compounds
- COMPONENTS
Respirable Dust
Portland cement (CAS# 65997-15-1) - approximately 2% to 26% by weight.
ACGIH TLV 10 mg/m3
OSHA PEL 15 mg/m3 5 mg/m3
OSHA PEL 50 mppcf (crystalline silica < 1%)
Cal/OSHA PEL 10 mg/m3 5 mg/m3
Aggregates (CAS# non e ) - approximately 36% to 92% by weight. (natural sand and gravel)
ACGIH TLV 10 mg/m3
OSHA PEL 15 mg/m3 5 mg/m3
Cal/OSHA PEL 10 mg/m3 5 mg/m3
Flyash (CAS# 68131-74-8) - approximately 0% to 25% by weight.
ACGIH TLV 10 mg/m3
OSHA PEL 15 mg/m3 5 mg/m3
Cal/OSHA PEL 10 mg/m3 5 mg/m3
Crystalline Silic a (CAS# 14808-60-7) - approximately 5% to 13% by weight.
ACGIH TLV 0.1 m g/m3
OSHA PEL 2 mg/m3
OSHA PEL 0.7 mg/m3
OSHA PEL 13.8 mppcf
Cal/OSHA PEL 0.3 mg/m3 0.1 mg/m3
Water (CAS# 77321-85) - approximately 6% to 13% by weight.
Trace Eleme nts:
Ready-Mix concrete is made from materials mined from the earth. Trace amounts of naturally occurring,
elements mi ght be detected during chemical analysis of these materials.
SECTION 1 -
Product Name:
Ready-Mix Concrete, Freshly Mixed Unhardened
Concrete
Supplier/M anu factur er :
Charley’s Concrete Co., Ltd.
P.O. Box 1106
Keller, Texas 76244
(817) 431-2016
Pr epared By:
GH
SECTION 2
Haz ar dous Ingr edients: Total Du st
(30 mg/m3 / (13% SiO2 +2))
(10 mg/m3 / (13% SiO2 +2))
(250 / (13% SiO2 +5)) mppcf
MS DS 0008 Page 2 of 7
SECTION 3 - HAZARDS IDENTIFICATION
Emergency Over view:
Short term ex posure to wet concrete is not likely to cause an immediate hazard. However, exposure of
sufficient duration to wet concrete can cause serious, potentially irreversible tissue (skin or eye) damage in the
form of chemical (caustic) burns. The same type of tissue damage can occ ur if wet or moist areas of the body
are exposed for s ufficient duration to the dry ingredients in unhardened concrete.
Routes of Exposur e:
Eye Contact
Expos ure to airborne dust during the handling or mixing of the dry ingredients in Ready-Mix concrete may
cause immedi ate or delayed irritation or inflammation.
Eye c ontact by splashes of wet concrete may cause effects ranging from moderate eye irritation to chemical
burns and blindness. Such exposures require immediate first aid (see Section 4) and medical att ention to
prevent significant damage to the eye.
Skin Contact
Disc omfort or pain cannot be relied upon to alert a person to a hazardous skin exposure. Consequently, the
only effective means of avoiding skin injury or illness involves minimizing skin contact, particularly contact
with wet c oncrete. Exposed persons may not feel discomfort until hours after the exposure has ended and
significant injury has occurred.
Exposure during the handling or mixing of the dry ingredients in Ready-Mix concrete may cause drying of
the skin wit h consequent mild irritation or more significant effects attributable to aggravation of other
conditions . Exposure to wet concrete may cause more severe skin effects including thickening, cracking or
fissuring of the skin. Prolonged exposure can cause severe skin damage in the form of (caustic) chemical
burns .
Some individuals may exhibit an allergic response upon exposure to wet concrete. The response may
appear in a variety of forms ranging from a mild rash to severe skin ulcers. Persons already sensitized may
react to their first contact with the product. Other persons may first experience this effect after years of
contact with wet unhardene d concrete products.
Ingestion
Although i nadvertent ingestion of small quantities of wet concrete or its dry ingredients are not known to be
harmful, accidental ingestion of larger quantities can be harmful and requires immediate medical attention.
Inhalation
The ingredients in Ready -Mix concrete contain crystalline silica. Exposure to these ingredients in excess of
the applicabl e TLV or PEL (see Section 2) may cause or aggravate other lung conditions.
Expos ure to the dry ingredients in Ready-Mix concrete may cause irritation to the moist mucous membranes
of the nos e, throat, and upper respiratory system
Medical Conditions which May be Aggravated by Inhalation or Dermal Expo sure:
Pre-ex isting upper respiratory and lung diseases by exposure to the dry ingredients.
Persons with unus ual (hyper) sensitivity to chemicals, dusts, and metallic compounds may experience advers e
reactions to wet c oncrete.
Carcinogenic Potential:
Ready-Mix conc rete is not listed as a carcinogen by NTP, OSHA, or IARC. It may, however, contain trace
amounts of substances listed as carcinogens by these organizations including but not limited to: crystalline
silica, hexavalent chromium, lead compounds, mercury compounds, nickel compounds, and possibly other
chemic als whic h may res ult in exposures which require the following warming pursuant to California Proposition
65:
WA RNING: This pro du ct contains chemicals know n to the State of California to cause cancer, birth
defects, or oth er r eproductive harm.
MS DS 0008 Page 3 of 7
SECTION 4 - FIRST AID
Eyes:
Immediately flush ey es thoroughly with water. Continue flushing eye for at least 15 minutes, including under
lids, to remove all particles. Call physician immediately .
Skin :
Wash skin with c ool water and pH-neutral soap or a mild detergent intended for use on skin. Seek medical
treatment in all cases of prolonged exposure to wet concrete, liquids from wet concrete products, or prolonged
wet skin exposure to the dry ingredients in Ready-Mix concrete.
Ingestion:
Do not induce vomiting. If conscious, have the victim drink plenty of water and call a physician immediately.
Inhalatio n of Airborne Du st:
Remov e to fresh air. Seek medical help if coughing and other symptoms do not subside. (Inhalation of gross
amounts of the dry ingredients in Ready-Mix concrete requires immediate medical attention.)
SECTION 5 - FIRE & EXPLOSION DATA
Flash Point ....................................................... None Extinguishing Media ..................... Not Combustible
Lo wer Explosive Limit .................................... None Special Fire Figh ting Procedures .................. None
Upp er Explosive Li mit .................................... None Hazardous Combustion Products ................. None
Auto Ignition T emper ature ........... Not Co mbustible Unusual Fire & Explosion Hazards ............... None
SECTION 6 - ACCIDENTAL RELEASE MEASURES
Collect dry material using a scoop. Avoid actions that cause dust to become airborne. Avoid inhalation of dust and
contact with skin.
Scrape up wet material and place in an appropriate container. Allow the wet concrete to "harden" before disposal.
Do not attempt to wash wet concrete down sewers or storm drains.
Wear appropriate pers onal protective equipment as described in Section 8.
Dispose of waste material according to local, state and federal regulations.
SECTION 7 - HANDLING & STORAGE
Normal temperatures and pressures do not affect the material.
Promptly remove dusty clothing or clothing which is wet with concrete and launder before reuse. Wash thoroughly
after exposure to dust or w et concrete mixtures.
SECTION 8 - EXPOSURE CONTROLS/PERSONAL PROTECTION
Eye Protection:
When engaged i n activities where wet concrete or its dry ingredients could contact the eye, wear safety glasses
with side shields or goggles. In extremely dusty environments and unpredictable environments, wear unvented
or indirectly vented goggles to avoid eye irritation or injury. Contact lenses should not be worn when working
with wet concrete or its dry ingredients.
MS DS 0008 Page 4 of 7
SECTION 8 - EXPOSURE CONTROL/PERSONAL PROTECTION (continued)
Skin Protection:
Preventi on is essential to avoiding potentially severe skin injury. Avoid contact with unhardened (wet) concrete
products or its dry ingredients. If contact occ urs, promptly wash affected area with soap and water. Where
prolonged expos ure to unhardened concrete products might occur, wear impervious clothing and gloves to
eliminate ski n contact. Where required, wear boots that are impervious to water to eliminate foot and ankle
ex posure.
Do not rely on barrier creams; barrier creams should not be used in place of gloves.
Periodically wash areas contacted by wet c ement or its dry ingredients wit h a pH neutral soap and water. Wash
again at the end of the work . If irritation occurs, immediately wash the aff ected area and seek treatment. If
clothing becomes s aturated with wet concrete, it should be removed and replaced with clean dry clothing.
Respiratory Protection :
Avoid actions that cause dust exposure to occur. Use local or general ventilation to control exposures below
applic able exposure limits.
NIOSH or MSHA approved particulate filter respirators should be used in the context of respiratory protection
program meeting the requirements of the OSHA respiratory protection standard [29 CFR 1910.134] to control
ex posures when ventil ation or other controls are inadequate or discomfort or irritation is experienced.
Respirator and/or filter cartridge selection should be based on American National Standards Institute (ANSI)
Standards Z88.2 Practi ces for Respiratory Protection.
Ventilation :
Use loc al exhaust or general dilution ventilation to control exposure within applicable limits.
SECTION 9 - PHYSICAL & CHEMICAL PROPERTIES
Appearance ........................... Gray Granular Mixture Vapor Pressure ................................. Not Applicable
Odor ................................................ No Distinct Odor Vapor Density .................................... Not Applic able
Physical State ................................................. Liquid Boiling Poin t ...................................... Not Applicable
Melting Poin t...................................... Not Applicable
Evaporation Rate...............................Not Applicable
STABILITY & REACTIVITY
Hazardous Deco mposition:
Will not spontaneously occur. Adding water
results in hydration and produces (caustic)
calcium hydroxide.
Incompatibility:
Wet Ready -Mix concrete is alkaline. As such it is
incompati ble with acids, ammonium salts and
aluminum metal.
Specific Gravity (H2O = 1) ..................... 1.70 to 3.00
pH (in water) (ASTM D 1293-95) ..................12 to 13
Solubility in W ater ........................... Slightly Soluble
SECTION 10 -
Stability:
Stable.
Conditions to Avoid :
Unintentional contact with wat er.
Hazardou s Polymerizatio n:
Will not occur.
MS DS 0008 Page 5 of 7
SECTION 11 - TOXICOLOGICAL INFORM ATION
NIOSH conducted a study, "The Mortality of U.S. Portland Cement and Quarry Workers" (March 1985) which found:
"There is no excess mortality from all causes of death, lung cancer, non-malignant respiratory disease, or ischemic
heart disease" among workers studied.
SECTION 12 - ECOLOGICAL INFORMATION
Ecotoxi city: Relevant Physical and Chemical Properties:
No recognized unusual toxicity to plant s or (See Sections 9 and 10.)
animals .
SECTION 13 - DISPOSAL
Dispose of waste material according to local, state and federal regulations. (Since Ready-Mix concrete is stable,
uncontaminated unused dry material may be saved for future use.)
SECTION 14 - TRANSPORTATION DATA
Haz ar dous Materials Description/Proper Shippi ng
Name:
Ready-Mix conc rete is not hazardous under U.S.
Department of Transportation (DOT) regulations.
Haz ard Class:
Not Applicable
SECTION 15 - OTHER REGULATORY INFORMATION
Status under O SHA Hazard Communication Standard, 29 CF R 1910.1200:
Unhardened Ready-Mix concrete is considered a "hazardous c hemical" under this regulation, and shoul d be
included in the employ er’s hazard communication program.
Reportable Quantities Un der th e Clean Water Act, CERCLA, and EPCRA, 40 CFR 117, 302 and 355:
Unhardened Ready-Mix concrete is not Listed.
Haz ard Category and Applicability o f EPCRA Hazardous Substance In ventory Reporting, 40 CFR 370:
Unhardened Ready-Mix concrete qualifies as a "hazardous subst ance".
Applicability of EPCRA Toxic Chemical Release Inventory (TRI) Reporting. 40 CFR 372:
Unhardened Ready-Mix concrete is not a TRI listed chemical, however TRI listed constituents are present in
conc entrations below the Supplier Notification De Minimus Levels.
Status Und er the Toxic S ubstances Control Act, 40 CFR 710:
Unhardened Ready-Mix concrete and the chemicals present in Unhardened Ready-Mix concrete are on the
TSCA inventory list.
Identification Number:
Not Applicable
Required Lab el Text:
Not Applicable
Hazardou s Sub stances/Reportabl e Quantities
(RQ):
Not Applicable
MS DS 0008 Page 6 of 7
SECTION 15 - OTHER REGULATORY INFORMATION (Continued )
Status under the Federal Hazardou s Substances Act and Its Reg ulations:
Unhardened Ready-Mix concrete is a "hazardous substance" subject to the following labeling requirements for
consumer us e:
WARNING: IN JURIOUS TO EYES. CAUSES SKIN IRRITATION. READ THIS WARNIN G BEFORE USING.
Contain s Portland Cement
Contact with wet (unhardened concrete, mortar, wet cement, or cement mixtures) can cause skin irritation,
severe chemic al burns, or serious eye damage. Avoid contact with eyes and skin. Wear waterproof gloves,
a fully buttoned long-sleeved shirt, full-length trousers, and tight fitting eye protection when working with
these materi als. If you have to stand in wet concrete, use waterproof boots that are tight at tops and high
enough to keep concrete from flowing into them. If you are finishing concrete wear knee pads to protect
knees. Wash wet concrete, mortar, wet cement, or cement mixtures from your skin with fresh, clean water
immediately after contact. Indirect contact through clothing can be as serious as direct contact, so promptly
rinse out wet concrete, mortar, wet cement, or cement mixtures from clothing. Seek immediate medical
attention if you have persistent or severe discomfort. In case of eye contact, flush with plenty of water for at
least 15 minutes. Consult a physician immediately.
KEEP OUT OF RE ACH OF CHIL DREN.
USER AGREES TO CONVEY THIS WARNING TO ALL PERSONS WHO MAY PURCHASE, USE OR
COME IN CONTACT WITH WET (UNHARDENED) CONCRETE, MORTAR, WET CEMENT OR CEMENT
MIXTU R E S
Status und er Wor kplace Hazardous Materials In formati on System (WH MIS), Canada:
Unhardened Ready-Mix concrete is considered to be a hazardous material under the Hazardous Products Act
as defined by the Controlled Products Regulations (Class E - Corrosive Material) and is therefore subject to the
labeling and MSDS requirements of the Workplace Ha zardous Materials Information System (WHMIS).
Status und er Canadian Environm ental Protection Act:
Not Listed.
SECTION 16 - OTHER INFORMATION
Other Impor tant Information:
Ready Mix conc rete s hould only be used by knowledgeable persons. A key to using the product safely requires
the user to recognize that portland cement chemically reacts with water, and that some of the intermediate
products of this reaction (that is, those present while a concrete product is "setting") pose a far more severe
hazard than does portland cement itself.
While the information provided in this material safety data sheet is believed to provide a useful summary of the
hazards of unhardened (wet) Ready-Mix concrete as it is commonly used, the sheet cannot anticipate and
provide all of the information that might be needed in every situation. Inexperienced product users should
obtain proper training before using this product.
In particular, the data furnished in this sheet does not address hazards that may be posed by materials other
than natural sands and gravels mixed with portland cement and flyash to produce Ready-Mix concrete products.
Users s houl d review other relevant material safety data sheets before working with this portland cement
concrete.
MS DS 0008 Page 7 of 7
SECTION 16 - OTHER INFORMATION (Continued)
Abbr eviations:
ACGIH
American Conference of Governmental
Industrial Hygienists
ANSI
American Nati onal Standards Institute
Cal/OSHA
Californi a Division of Occupational Safety
and Health Administration
CAS
Chemic al Abstract Service
CERCLA
Federal Comprehensive Environmental
Response, Compens ation, and Liability Act
(Superfund)
CFR
Code of Federal Regulations
DOT
Department of Transportation
EPCRA
Emergency Planni ng and Community Right-
to-Know Act of 1986
IARC
International Agency for Research on Canc er
m3
Cubic Meter
mg
Milligram
mppcf
Million Particles per Cubic Foot
SELLER MAKES NO WARRANTY, EXPRESS OR IMPLIED, CONCERNING THE PRODUCT OR THE MERCHANTABILITY
OR FITNESS THEREOF FOR ANY PURPOSE OR CONCERNING THE ACCURACY OF ANY INFORMATION PROVIDED BY
CHARLEY’S CONCRETE , except that the product shall conform to contracted specifications. The information provided
herein was believed by Charley’s Concrete to be accurate at the time of preparation or prepared from sources believed to
be reliable, but it is the responsibility of the user to investi gate and understand other pertinent sources of information to comply
with all laws and procedures applicable to the safe handling and use of the product and to determine the suitability of the product
for its intended use. Buyer's exclusive remedy shall be for damages and no claim of any kind, whether as to product delivered or
for non-delivery of product, and whether based on contract, breach of warranty, negligence, or otherwise shall be greater in
amount than the purchase price of the quantity of product in respect of which damages are claimed. In no event shall Seller be
liable for incidental or consequential damages, whether Buyer's claim is based on contract, breach of warranty, negligence or
otherwise.
MSDS
Material Safety Data Sheet
MSHA
Mine Safety and Health Administration
NIOSH
National Institute of Occupational Safety and
Health
NTP
National Toxicology Program
OSHA
Occupational Safety and Health
Administration
PEL
Permissable Exposure Limit
RQ
Reportable Quantities
SiO2
Crystalline Silica, Quartz
TLV
Threshold Limit Values
TRI
Toxic Release Inventory
TSCA
Toxic Substance Control Act
WHMIS
Workplace Hazardous Materials Information
System