Freeport NIP(2.3)-LR000414TECHNOLOGIES INC Maxim Technologies Inc. 2200 Gravel Drive Fort Worth, Texas 76118-7123 Telephone: (817) 284-7755 Fax: (817) 589-1420 REPORT OF CONCRETE COMPRESSIVE STRENGTH CLIENT: FAST TRAK CONSTRUCTION 1150 EMPIRE CENTRAL PLACE SUITE 124 ATTENTION: MR. KENT DALRYMPLE DALLAS, TX 75247 PROJECT: STAPLES-440 N ROYAL LANE Coppell, Texas PAGE 1 PROJECT NO.: 9711090 REPORT NO.: 024129 DATE OFSER~CE: 4/07/2000 AUTHORIZA~ON: REPORT DATE: 4/14/2000 SERVICES: Sample concrete at location of placement, perform required field tests, prepare and test concrete compressive strength specimens. CONTRACTOR: FAST TRAK CONSTRUCTION CONCRETE SUPPLeR: Mid-Cities PLANT: 9351 SPECIFICA~ONREQUIREMENTS STRENGTH: 4000psi @ 28 DAYS SLUMP: 4"-6" AIR: 4%-'6% METHOD OF TEST SAMPLING: ASTM C172 MOLDING &CURING: ASTM C31 SLUMP: ASTM C143 TEMPERATURE: ASTM C1064 AIR CONTENT: ASTM C231 UNITWEIGHT: ASTM C138 CAPPING~ADS: ASTM C1231 TESTING: ASTM C39 CYLINDER MARKED DATE SET NO. TESTED I I 4/14/2000 1 2 5/05/2000 1 3 5/05/2000 PROJECT DATA CLASS OF CONCRETE: 9351 DATE OF PLACEMENT: 4 / 07 / 2000 TIME SAMPLED: 12: 32 PM TEMPERATURE ~egl9 - AIR: 86 TRUCK NO: 490 MEASURED SLUMP (i-.): 8.00 AIR CONTENT(%): 5.5 LOCATION OF PLACEMENT: South Parking BY: JACK FARRIS CONCRETE: 78 ~CKET NO: 40789 UNIT WEIGHT(pc0: NA REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE AGE DIAMETER AREA LOAD STRENGTH (days) (in.) (sq.in.) (lbs. force) (psi) FRACTURE TYPE 7 6.00 28.27 88300 3120 CONE 28 28 1 4 HOLD Technician: JACK FARRIS Started: 09:00AM Stopped: 03:30PM CME TECHNICIAN Report Of Tests Continued On Page 2 Our tetters and repons ate for u'~ exctmivc uae of the cliem to whom tl~y arc add~', s,vcd a~. shall no~ be.rep~rod .uc, ed except, ia full withoat thc approval of ~h~ tc~ting .laboratory. The use o(ogr .mum must rote,ye, mtr .written al]prgya~., u? t~.~. a~ ~ 1(301 MR apply only to ~he sample tested and/or tmpec~l, and at~ not mdtcauve of t]~ quazmu~ of ~y ~aenncai or s~rmmr pr~aucts. FAST TRAK CONSTRUCTION PROJECT NO. 9711090 DATE OF SERVICE: 4 / 07 / 2000 REPORT NO. PAGE 2 SET NO. 2 024129 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Continued) CONTRACTOR: FAST TRAK CONSTRUCTION CONCRETE SUPPLIER: Mid-Cicies PLANT: 9351 SPECIFICATION REQUIREMENTS STRENGTH: 4000psi @ 28 DAYS SLUMP: 4"-6" AIR: 4%-6% MF. THOD OF TEST SAMPLING: ASTM C172 MOLDING & CURING: ASTM C31 SLUMP: ASTM C143 TEMPERATURE: ASTM C1064 AIR CONTENT: ASTM C231 UNIT WEIGHT: ASTM C138 CAPPINGfPADS: ASTM C1231 ~G: ASTM C39 CYLINDER MARKED DATE SET NO. TESTED PROJECT DATA CLASS OF CONCRETE: 9351 DATE OF PLACEMENT: 4 / 07 / 2000 TIME SAMPLED: 07: 18AM BY: JACK FARRIS TEMPERATURE (Deg~ - AIR:62 CONCRETE: 73 TRUCKNO: 829 TICKETNO: 1549634 MEASURED SLUM~ (i..): 4.25 AIR CONTENT(%): 5.2 UNIT WEIGHT(pc0: NA LOCATION OF PLACEMENT: Paving between The Atrum and Hanger on Northside of Atrum REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE AGE DIAMETER AREA LOAD STRENGTH (days) (in.) (sq.in.) (lbs. force) (psi) FRACTURE TYPE 2 1 4/14/2000 7 2 2 5/05/2000 28 2 3 5/05/2000 28 6.00 28.27 80920 2860 CONE 2 4 HOLD Technician: JACK FARRIS Started: 05:30AM CME TECHNICIAN Report Distribution: I1) FAST TRAK CONSTRUCTION 1) CITY OF COPPELL lOOt MR Stopped: 09:00AM ~ ~HNOLOGII~S INC. Tim Begole, CET. Office Manager Our letters an~ repons are for ~ exclusive use of tim client to whom they ate addressed and shall not be _rep~xxlue~d except in full without th~ approval of the t~stin8 laboratory. Thc u,~ of our nam~ must r~ceive our writ~n aL)proval.. Our I .c~.n. and t~uom apply only to thc sample ~s~xt and/or inspected, and ate not indicative of the quamiticm of appa~nuy id~nucal of s.mler ~edu~m,