Loading...
9th Grade Center-170501Utility Piping Product Data Submittal #330000-001.A Status:Submitted 04/24/2017 Submittal Response Needed By:04/27/2017 Owner:Coppell ISD Use Master Format Specification Number: Specification Number:330000 Sub-Contractor Org:Corgan Associates, Inc. Submit To:Corgan Associates, Inc.Submitting Organization:Northstar Builders Sent By:Owner-Insite Project:Coppell 9th Grade Center Tracking #:Submitted Date:04/24/2017 Number of Sets:Change Proposals:Create Change Proposal Initiator:Jeff Miller Categories: Requested By Contractor On:Received By Contractor On: Submittal Notes: The attached utility piping product data submittal is for review and approval. Change Proposal Request Will this Submittal have a cost impact? Yes No Will this Submittal have a time impact? Yes No Submittal Action Response: Action: Comments FORT WORTH, TX 76111 1888 WEST NORTHWEST HWY DALLAS, TX 75220 PROJECT NAME: COPPELL 9TH GRADE WILDSTONE CONSTRUCTION CUSTOMER: PROJECT LOCATION: COPPELL, TX ENGINEER: GLENN ENGINEERING MATERIAL SUBMITTALS 2585 NORTHEAST 28TH STREET SECTION 7: DUCTILE IRON FITTINGS, RESTRAINTS, & ACCYS SECTION 8: FIRE LINE RISERS SECTION 9: WATER SERVICE MATERIALS SECTION 10: POLYWRAP, POLYTAPE, TRACER WIRE & FILTER FABRIC SECTION 6: FIRE HYDRANTS TABLE OF CONTENTS SECTION 1: STORM SEWER PIPE & FTGS SECTION 2: INLINE DRAIN BASINS SECTION 3: SANITARY SEWER PVC PIPE, FITTINGS & CLEANOUTS SECTION 4: WATER PIPE SECTION 5: GATE VALVES & VALVE BOXES SECTION 1: STORM SEWER PIPE & FTGS BENEFITS JM Eagle’s Eagle Corr PE Dual Wall is better engineered for a more durable joint and long-lasting performance. Eagle Corr PE Dual Wall: • Is made from HDPE, one of the most chemically inert plastics, and is ex- tremely resistant to corrosion, as well as abrasion, gouging and scratching. • Features dual crown corrugation for greater pipe stiffness values. • Is expected to significantly exceed 100 years of design service life. • Features an integral bell and dual-gasket spigot for a superior watertight connection. • Saves money on installation costs due to its 20-foot lengths and light weight for easier handling and transport. DESCRIPTION JM Eagle’s Eagle Corr PE Dual Wall pipe in 4- to 10-inch diameters meets AASHTO M252 and ASTM F2648. In 12- to 60-inch diameters, it meets AAS- HTO M294 and ASTM F2306 and ASTM F2648. It comes in 20-foot lengths. Eagle Corr PE Dual Wall features a dual-crown corrugated exterior for greater pipe stiffness values and a hydraulically smooth interior for maxi- mum efficiency. Its superior strength-to-weight ratio and flexible conduit design mean it will support H-25 live loads with a minimum cover of 1 foot, (except for 60-inch, which requires a 2-foot cover), while allowing for cover heights in excess of 100 feet. A full line of soil-tight and watertight (10.8 psi) fabricated fittings are avail- able for Eagle Corr PE, with custom fittings available upon request. Plain- end custom lengths are also available. APPLICATIONS JM Eagle’s Eagle Corr PE Dual Wall pipe is suitable for use in gravity flow drainage in DOT/capitol improvement, residential, commercial, recreational, agricultural and irrigation applications. Building essentials for a better tomorrow EAGLE CORR PE™ DUAL WALL MEETS AASHTO M252 AND AASHTO M294, AND ASTM F2648 AND F2306. GASKETS MEET ASTM F477. JOINTS MEET ASTM D3212. PLEASE CONTACT YOUR JM EAGLE REPRESENTATIVE OR VISIT WWW.JMEAGLE.COM FOR MORE INFORMATION. R e v i s e d 3 / 9 / 2 0 1 2 . T h i s i n f o r m a t i o n m a y h a v e b e e n u p d a t e d . P l e a s e d o w n l o a d t h e l a t e s t v e r s i o n a t w w w . j m e a g l e . c o m / o n e s h e e t s . Building essentials for a better tomorrow EAGLE CORR PE™ DUAL WALL SUBMITTAL AND DATA SHEET NOMINAL I.D. IN (MM) APPROX. O.D. IN (MM) LAYING LENGTH (FT) PIPE STIFFNESS PSI AVERAGE UNIT WEIGHT LB/FT 4 (100)5 (120)20 50 0.4 6 (150)7 (174)20 50 1.1 8 (200)9 (231)20 50 1.7 10 (250)11 (290)20 50 2.5 12 (300)14 (363)20 50 3.2 15 (375)17 (444)20 42 4.8 18 (450)21 (529)20 40 6.3 24 (600)28 (699)20 34 11.2 30 (750)35 (880)20 28 15.8 36 (900)42 (1055)20 22 20.9 42 (1050)47 (1204)20 20 26.9 48 (1200)54 (1367)20 18 34.0 60 (1500)67 (1693)20 14 56.0 THIS SPECIFICATION REFERS TO 4"-60" PIPE FOR USE IN GRAVITY FLOW DRAINAGE APPLICATIONS. O.D.I.D. 177 98.6 756 50.5 22.2 879.5 PRODUCT STANDARD: PIPE COMPOUND: GASKET: JOINT PERFORMANCE: FITTINGS: INSTALLATION: 4"-10" AASHTO M252 and ASTM F2648 12"- 60" AASHTO M294, ASTM F2306 and ASTM F2648 ASTM D3350 ASTM F477 ASTM D3212 AASHTO M252; AASHTO M294; ASTM F2306; ASTM F2648 ASTM D2321; Eagle Corr PE Installation Guide R e v i s e d 3 / 9 / 2 0 1 2 . T h i s i n f o r m a t i o n m a y h a v e b e e n u p d a t e d . P l e a s e d o w n l o a d t h e l a t e s t v e r s i o n a t w w w . j m e a g l e . c o m / o n e s h e e t s . BENEFITS JM Eagle’s Ring-Tite Gravity Sewer pipe features an improved design for re-serve strength and stiffness to increase load-bearing capacity, maximizing sewer system capacity at a reasonable cost. • It is unaffected by the fluids found in ordinary domestic sewage; sewer gasses and the sulfuring acid generated by the completion of the hydrogen sulfide cycle; and corrosive soils both alkaline and acidic. • Maintains performance against tuberculation, corrosion and external galvanic soil conditions without lining wrapping, coating or cathodic protection. • It resists abrasion, gouging and scouring far better than most common piping materials. • Its interiors stay smooth over long years of service while maximizing system capacity, allowing for savings in pumping costs, as well as savings on the size of the pipe required. • The light weight of the pipe reduces manpower required for installation. • It can be field-cut with a power saw or ordinary handsaw and be beveled without the use of expensive or complicated machinery. • Gasketed tee and wye saddles for tapping into previously installed PVC sewer lines eliminate the need for field solvent welding. DESCRIPTION JM Eagle’s Gravity Sewer pipe ASTM D3034 is available in SDR 35 and SDR 26 in 4- to 15-inch diameters and ASTM F679 is available in PS 46 and PS 115 in 18- to 48-inch diameters. It comes in 14- and 20-foot lengths. The pipe can be directed to most existing sewer equipment. It can also be con- nected to IPS cast- or ductile-iron fittings with the appropriate adapters and/or tran- sition gaskets. JM Eagle Gravity Sewer pipe comes with Ring-Tite joints with locked-in gaskets. Joints meet or exceed ASTM D3212 for joint tightness, including a 22-inch Hg vac- uum and a 25-foot head pressure test. APPLICATIONS JM Eagle’s Ring-Tite PVC Gravity Sewer pipe is suitable for conveying domes- tic sanitary sewage, as well as certain industrial wastes. Building essentials for a better tomorrow GRAVITY SEWER MEETS ASTM D3034 AND F679. PLEASE CONTACT YOUR JM EAGLE REPRESENTATIVE OR VISIT WWW.JMEAGLE.COM FOR MORE INFORMATION. R e v i s e d 5 / 1 4 / 2 0 1 2 . T h i s i n f o r m a t i o n m a y h a v e b e e n u p d a t e d . P l e a s e d o w n l o a d t h e l a t e s t v e r s i o n a t w w w . j m e a g l e . c o m / o n e s h e e t s . JM EAGLE’S RING-TITE JOINT OFFERS ADDITIONAL BENEFITS. • Seated in a deep groove, the flexible elastomeric Rieber gasket provides a tight seal that protects the line from shock, vibration and earth movement, and compensates for expansion and contraction of the pipe lengths. • Quick and easy to assemble with a simple push, there’s no field mixing or application of cement. • The joint remains tight under normal operating conditions. Building essentials for a better tomorrow GRAVITY SEWER SUBMITTAL AND DATA SHEET PIPE SIZE (IN) AVERAGE O.D.(IN) NOM. I.D. (IN) MIN. T. (IN) MIN. E (IN) APPROX. D9 (IN) APPROX. WEIGHT (LBS/FT) SDR 35 (PS46) ASTM D3034 4 4.215 3.975 0.120 3.50 4.695 1.05 6 6.275 5.915 0.180 4.25 6.995 2.36 8 8.400 7.920 0.240 4.75 9.360 4.24 10 10.500 9.900 0.300 6.00 11.700 6.64 12 12.500 11.780 0.360 6.25 13.940 9.50 15 15.300 14.426 0.437 7.25 17.048 14.19 SDR 26 (PS115) ASTM D3034 4 4.215 3.891 0.162 3.50 4.863 1.40 6 6.275 5.793 0.241 4.25 7.239 3.11 8 8.400 7.754 0.323 4.75 9.692 5.63 10 10.500 9.692 0.404 6.00 12.116 8.84 12 12.500 11.538 0.481 6.25 14.424 12.56 15 15.300 14.124 0.588 7.25 17.652 18.90 PS46, ASTM F679 18 18.701 17.629 0.499 8.00 20.845 21.43 21 22.047 20.783 0.588 9.50 24.575 29.88 24 24.803 23.381 0.661 9.60 27.647 38.96 27 27.953 26.351 0.745 10.10 31.157 49.47 30 CIOD 32.000 30.194 0.853 16.75 35.612 64.18 36 CIOD 38.300 36.042 1.021 19.02 42.816 93.00 42 CIOD 44.500 41.948 1.187 22.43 49.604 — 48 CIOD 50.800 47.888 1.355 24.78 56.624 — PS115, ASTM F679 18 18.701 17.261 0.671 8.00 21.581 28.49 21 22.047 20.349 0.791 9.50 25.443 — 24 24.803 22.891 0.889 9.60 28.627 — 27 27.953 25.799 1.002 10.10 32.261 — 30 CIOD 32.000 29.070 1.148 16.75 36.348 — 36 CIOD 38.300 35.464 1.373 19.02 45.438 — 42 CIOD 44.500 41.072 1.596 22.43 51.356 — 48 CIOD 50.800 46.886 1.822 24.78 58.628 — Product Standard: Pipe Compound: Gasket: Integral Bell Joint: Pipe Stiffness: Pipe Length: Installation: ASTM 3034 (4”–15”) ASTM F679 (18”–48”) ASTM D1784 Cells Class 12454 or 12364 ASTM F477 ASTM D3212 ASTM D2412 F/Y = 46 PSI or 115 PSI 14 or 20 feet laying length ASTM D 2321 JM Eagle™ Installation Guide 9 9 R e v i s e d 5 / 1 4 / 2 0 1 2 . T h i s i n f o r m a t i o n m a y h a v e b e e n u p d a t e d . P l e a s e d o w n l o a d t h e l a t e s t v e r s i o n a t w w w . j m e a g l e . c o m / o n e s h e e t s . SECTION 2: INLINE DRAIN BASINS Inline Drains are typically used for the non-pressure drainage of surface water runoff and are intended to be installed on top of a riser pipe that connects to the storm sewer system. Drain Basins are typically used for the non-pressure drainage of surface and subsurface storm water and provide a collection point for any storm water collection system. Inline Drains / Drain Basins are manufactured out of rigid PVC PSM/PS46 piping that meets the material cell classification of 12454 or 12364 as defined in ASTM D1784. Outlet Connections are available for a wide array of water tight connections to include certain sizes of Corrugated HDPE. Connections for PVC PSM, IPS, C900 and certain PVC profile pipes are also available. Elastomeric Seals The joint gaskets meet or exceed the standard specification for joining plastic pipe as defined in ASTM F477. Joint Requirement The joint is designed to meet the internal pressure requirements of 10.8 PSI as described in ASTM D3212. Drain Grate Castings - Manufactured from Ductile Iron or Cast Iron and available in a variety of grate types and styles. The grates conform to the casting requirements of ASTM A48 or ASTM A536. Grates and rings are also available as H-20/H25 traffic load rated or ADA compliant, as specified. Installation Guidelines Drain basin structures and Inline drains are designed to be installed using the same installation guidelines as defined in ASTM D2321 for the installation of underground rigid PVC pipe. Appropriate rated embedment materials shall be used and compacted so as to minimize deflections. For particular installations, the professional engineer should verify the percent of compaction meets the performance requirements. A concrete support slab 18” x 8” minimum thickness is required for all traffic load applications. The actual concrete dimensions should be designed according to the local standards by a professional engineer. Drain Basins GPK’s Drain Basins are the perfect fit for any storm water collection system. Drain Basins provide collection points, while offering connections for different types of pipe, sizes, and differing pipe elevations. GPK Drain Basins are made specific to your drainage needs. inline Drains Inline Drains provide collection points at the beginning of a line in a storm water collection system or at any point where collection is needed on a storm water line. Through the use of a 90 degree bend or a tee with a vertical riser an inline drain can be used for any storm water collection need. www.gpk-fargo.com • 1601 43rd St. N • Fargo, ND 58102 • Ph 701-277-3225 • Toll Free Ph 800-437-4670 • Fax 701-277-9286 or 800-822-6989 Drain Basin Drain Basin with Pipe BeneFiTs: Water Tight Joints: GPK’s Drain Basins and inline Drains offer a wide array of water tight connections including Corrugated HDPE, and PVC pipes to include SDR35, SDR26, SCH40, C900, and other profile pipes. Custom Made: GPK’s Drain Basins are custom made to ensure the exact design of virtually any storm water system is met. reduced installation Time: Installation time is reduced when compared to alternatives such as concrete structures. Inline Drains All GPK Drain Basins, Inline Drains and most grates are Made in America. Drainage ProDucts suMP eliMinaTor The Sump Eliminator is installed during the production process at the level of the lowest outlet. The Sump Eliminator prevents water pooling by guiding the collected water through the lowest outlet. The elimination of pooling stagnant water helps prevent the growth of bacteria and insect reproduction. www.gpk-fargo.com • 1601 43rd St. N • Fargo, ND 58102 • Ph 701-277-3225 • Toll Free Ph 800-437-4670 • Fax 701-277-9286 or 800-822-6989 Sump Eliminator GraTes & Covers GPK offers a variety of different grates and covers which can be ordered with the Drain Basins and Inline Drains, including a variety of different load ratings along with pedestrian ADA compliant grates. Grate/Cover Options Include (but are not limited to): Drop in, Round with Frame, Domed, Square Hinged, Curb Inlet, Traffic, and Solid Covers. Accessories such as locking mechanism can also be ordered. Domed Grate with Frame Drop in Domed Grate Round Drop in Grate Round Grate with Frame Square Hinged Grate Drainage ProDucts All GPK Drain Basins, Inline Drains and most grates are Made in America. SECTION 3: SANITARY SEWER PVC PIPE, FITTINGS & CLEANOUTS BENEFITS JM Eagle’s Ring-Tite Gravity Sewer pipe features an improved design for re-serve strength and stiffness to increase load-bearing capacity, maximizing sewer system capacity at a reasonable cost. • It is unaffected by the fluids found in ordinary domestic sewage; sewer gasses and the sulfuring acid generated by the completion of the hydrogen sulfide cycle; and corrosive soils both alkaline and acidic. • Maintains performance against tuberculation, corrosion and external galvanic soil conditions without lining wrapping, coating or cathodic protection. • It resists abrasion, gouging and scouring far better than most common piping materials. • Its interiors stay smooth over long years of service while maximizing system capacity, allowing for savings in pumping costs, as well as savings on the size of the pipe required. • The light weight of the pipe reduces manpower required for installation. • It can be field-cut with a power saw or ordinary handsaw and be beveled without the use of expensive or complicated machinery. • Gasketed tee and wye saddles for tapping into previously installed PVC sewer lines eliminate the need for field solvent welding. DESCRIPTION JM Eagle’s Gravity Sewer pipe ASTM D3034 is available in SDR 35 and SDR 26 in 4- to 15-inch diameters and ASTM F679 is available in PS 46 and PS 115 in 18- to 48-inch diameters. It comes in 14- and 20-foot lengths. The pipe can be directed to most existing sewer equipment. It can also be con- nected to IPS cast- or ductile-iron fittings with the appropriate adapters and/or tran- sition gaskets. JM Eagle Gravity Sewer pipe comes with Ring-Tite joints with locked-in gaskets. Joints meet or exceed ASTM D3212 for joint tightness, including a 22-inch Hg vac- uum and a 25-foot head pressure test. APPLICATIONS JM Eagle’s Ring-Tite PVC Gravity Sewer pipe is suitable for conveying domes- tic sanitary sewage, as well as certain industrial wastes. Building essentials for a better tomorrow GRAVITY SEWER MEETS ASTM D3034 AND F679. PLEASE CONTACT YOUR JM EAGLE REPRESENTATIVE OR VISIT WWW.JMEAGLE.COM FOR MORE INFORMATION. R e v i s e d 5 / 1 4 / 2 0 1 2 . T h i s i n f o r m a t i o n m a y h a v e b e e n u p d a t e d . P l e a s e d o w n l o a d t h e l a t e s t v e r s i o n a t w w w . j m e a g l e . c o m / o n e s h e e t s . JM EAGLE’S RING-TITE JOINT OFFERS ADDITIONAL BENEFITS. • Seated in a deep groove, the flexible elastomeric Rieber gasket provides a tight seal that protects the line from shock, vibration and earth movement, and compensates for expansion and contraction of the pipe lengths. • Quick and easy to assemble with a simple push, there’s no field mixing or application of cement. • The joint remains tight under normal operating conditions. Building essentials for a better tomorrow GRAVITY SEWER SUBMITTAL AND DATA SHEET PIPE SIZE (IN) AVERAGE O.D.(IN) NOM. I.D. (IN) MIN. T. (IN) MIN. E (IN) APPROX. D9 (IN) APPROX. WEIGHT (LBS/FT) SDR 35 (PS46) ASTM D3034 4 4.215 3.975 0.120 3.50 4.695 1.05 6 6.275 5.915 0.180 4.25 6.995 2.36 8 8.400 7.920 0.240 4.75 9.360 4.24 10 10.500 9.900 0.300 6.00 11.700 6.64 12 12.500 11.780 0.360 6.25 13.940 9.50 15 15.300 14.426 0.437 7.25 17.048 14.19 SDR 26 (PS115) ASTM D3034 4 4.215 3.891 0.162 3.50 4.863 1.40 6 6.275 5.793 0.241 4.25 7.239 3.11 8 8.400 7.754 0.323 4.75 9.692 5.63 10 10.500 9.692 0.404 6.00 12.116 8.84 12 12.500 11.538 0.481 6.25 14.424 12.56 15 15.300 14.124 0.588 7.25 17.652 18.90 PS46, ASTM F679 18 18.701 17.629 0.499 8.00 20.845 21.43 21 22.047 20.783 0.588 9.50 24.575 29.88 24 24.803 23.381 0.661 9.60 27.647 38.96 27 27.953 26.351 0.745 10.10 31.157 49.47 30 CIOD 32.000 30.194 0.853 16.75 35.612 64.18 36 CIOD 38.300 36.042 1.021 19.02 42.816 93.00 42 CIOD 44.500 41.948 1.187 22.43 49.604 — 48 CIOD 50.800 47.888 1.355 24.78 56.624 — PS115, ASTM F679 18 18.701 17.261 0.671 8.00 21.581 28.49 21 22.047 20.349 0.791 9.50 25.443 — 24 24.803 22.891 0.889 9.60 28.627 — 27 27.953 25.799 1.002 10.10 32.261 — 30 CIOD 32.000 29.070 1.148 16.75 36.348 — 36 CIOD 38.300 35.464 1.373 19.02 45.438 — 42 CIOD 44.500 41.072 1.596 22.43 51.356 — 48 CIOD 50.800 46.886 1.822 24.78 58.628 — Product Standard: Pipe Compound: Gasket: Integral Bell Joint: Pipe Stiffness: Pipe Length: Installation: ASTM 3034 (4”–15”) ASTM F679 (18”–48”) ASTM D1784 Cells Class 12454 or 12364 ASTM F477 ASTM D3212 ASTM D2412 F/Y = 46 PSI or 115 PSI 14 or 20 feet laying length ASTM D 2321 JM Eagle™ Installation Guide 9 9 R e v i s e d 5 / 1 4 / 2 0 1 2 . T h i s i n f o r m a t i o n m a y h a v e b e e n u p d a t e d . P l e a s e d o w n l o a d t h e l a t e s t v e r s i o n a t w w w . j m e a g l e . c o m / o n e s h e e t s . 1.0 GPK PVC Sewer Fittings shall be manufactured in accordance with either ASTM D 3034, F1336 or F 679. The PVC material shall have a minimum cell classification of 12454, 13343 or 12364 as defined in ASTM D 1784. 2.0 The purpose of GPK in-line fittings is to convey municipal sanitary and industrial wastes, storm water runoff and many other related applications. They are designed to be used in gravity flow and low pressure applications not to exceed 10.8 psi. (74.5 kPa). 3.0 Injection Molded Fittings are produced in sizes 4” (100mm) through 12” (300mm) diameter. Fabricated Fittings are produced in sizes 4” (100mm) through 36” (973mm) diameter. A fabricated fitting is considered any fitting made from pipe or a combination of pipe and molded components. 4.0 Chemical Resistance GPK fittings resist attack from certain alcohols, alkalies, salt solutions, acids and other types of chemicals. Refer to chemical resistant chart for suitability. 5.0 Marking. GPK fittings shall be marked with applicable size, “PVC”, company name or logo, PSM and the ASTM specification number (D 3034, F 1336 or F679). The fittings and/or packaging shall include the manufacturer’s date and shIft code. 6.0 Testing. A test after installation of either low pressure air (Uni-B-6) or a water infiltration-exfiltration test is recommended. 7.0 Deflection Test. The maximum allowable pipe fitting deflection should be 7 ½% of base ID as shown in table X1.1 of D 3034, and X2.1 of F 679. 8.0 Backfilling and Tamping. Backfilling should follow closely after assembly of pipe and fittings. 8.1 Backfilling. with proper material is important to achieve desired density in haunching area whi ch enables pipe, fitting and soil to work together to meet designed load requirements. This eliminates excess deflection and shear breaks due to heavy loads. Approved material shall be used properly, compacted continuously above and around the pipe and f ittings as well as between fitting and trench wall. A cushion of approved material up to a minimum of 12” (305mm) over the fittings and between the trench walls shall be applied in accordance with the engineers ’ specifications. 8.2 Tamping. This shall be done by hand tamping of the embedment material between the trench wall of the service line fitting and riser connection. Tamping can also be done by mechanical tampers or by using water to consolidate the embedment material. Extreme unstable ground conditions may require wider trenches to enable you to compact a larger area around the pipe and fitting s to the density consistent of the original ground surface conditions. 9.0 Service Lines. Normally, service lines from the property line to the collection sewer should be a minimum depth of 3 feet (1 meter) at the property line and should be laid in straight alignment and uniform slope of not less than ¼” per foot (20.8mm/meter) for 4” (100mm) nominal pipe and 1/8” (10.4mm/meter) per foot for 6” (150mm) pipe. Where collection sewers are deeper than 7 feet (2 meters) a vertical standpipe or stack is permitted but not recommended, consult the project engineer for proper installation details. Deep sewer chimney and risers necessitate extreme care during backfillin g. Where surface loading is anticipated the final backfill must be compacted to a density compatible with those surface loads to be encountered. 9.1 Backfilling around pipe service laterals on slope. Extra attention should be given on slopes to prevent the newly backfilled trench from becoming a “French Drain”. Before backfilling completely there is a tendency for ground and surface water to follow the direction of the looser soil. This flow may wash out soil from under or around pipe and branch line fit tings, reducing or eliminating the support needed. To avoid this problem the backfilling should be of greater compaction. Tamping should be done in 4” (100mm) layers and continued in this manner all the way up to the ground or surface line of the trench. Concrete collars or other concrete poured around the fitting to stabilize unwanted movement is recommended to prevent water from undercutting the underside of the pipe and fittings. Summary: Due to various ground conditions and different situations, installation techniques vary widely. We warranty our products to be free of manufacturer’s defects. We will not replace the products that are installed or used incorrectly. The design of the systems that our product is used in is a factor that cannot be overlooked. SDR35 D 3034 / PS46 F 679 FITTING SPECIFICATIONS 811 1 GPK FITTING SUBMITTAL SHEET Intro: GPK manufactures PVC sewer fittings in accordance with either ASTM D 3034, F 1336 or F 679 to be used in gravity flow or low pressure applications. Injection molded fittings are produced in sizes 4” (100mm) through 12” (300mm) diameter. Fabricated fittings are produced in sizes 4” (100mm) through 36” (973mm) diameter. Material: Fabricated fittings are manufactured from PVC pipe and molded components meeting the requirements of either ASTM D 3034, F 1336 or F 679 for workmanship, extrusion quality, stiffness, impact resistance, dimensions and structural performance. Extruded pipe components are made from PVC material with a minimum cell classification of 12454, 13343 or 12364 as defined in ASTM D1784. Injection molded fittings are made from PVC material with a minimum cell classification of 12454 or 13343 as defined in ASTM D 1784. Extrusion Quality: Extruded components are tested in accordance with and meet the requirements of ASTM D 2152 for properly fused PVC. Impact Resistance: Extruded Components are tested in accordance with AS TM D 2444 using a 20 lb (9.07kg). Tup A and a Flat Plate Holder B. The strength shall equal or exceed the values shown below: 4” – 5” 150 Ft-Lbs 6” – 8” 210 Ft-Lbs 10” – 36” 220 Ft-Lbs (100mm – 125mm 203 J) (150mm – 200mm 284 J) (250mm – 973mm 299 J) Impact Resistance: Injection molded fittings are tested in accordance with ASTM D 2444 using a 20 lb (9.07kg). Tup A and a Flat Plate Holder B. The strength shall equal or exceed the values shown below: 4” 50 Ft-Lbs 6” – 8” 75 Ft-Lbs 10” – 12” 90 Ft-Lbs (100mm 68 J) (150mm – 200mm 102 J) (250mm – 300mm 122 J) Pipe Stiffness: Extruded Components are tested in accordance with ASTM D 2412. The stiffness equals or exceeds the requirements of ASTM D 3034 and F 679. Pipe Flattening: Extruded components are flattened as described in ASTM D 3034 and F 679 until the distance between the plates is 40% of the outside diameter of the pipe. There shall be no splitting, cracking or breaking. Pressure/Pressure Deflection: Gasketed joints are tested in accordance with ASTM D 3212. Pressure: 10 minutes @ 10.8 psi (74.5 kPa) + 10 minutes deflected @ 10.8 psi (74.5 kPa). Vacuum: 10 minutes @ 22 in. Hg (74 kPa) + 10 minutes deflected @ 22 in. Hg (74kPa). Branch Bending: The chemically fused areas around the fabricated branches of tee, wye and tee-wye fittings are tested to ASTM F 1336 to verify their strength and integrity. Pipe Stop Support: Tee and tee-wye fittings are tested to requirements of ASTM F 1336 for pipe stop load support. No cracking or splitting shall occur and pipe spigot shall not protrude into waterway of the fitting. Joining Methods: Chemically Fused Solvent Weld Joints Solvent cement is handled and tested in accordance with ASTM D 2564 and D 2855. The Lap Shear Strength shall equal or exceed 900 psi (6205 kPa) @ 72 hours. Heat Fusion Welded Joints (Butt Fusion Welds) Elastomeric Seals (Gaskets) Must meet all requirements of ASTM F 477 and D 3212. Saddles: Injection Molded saddle tees and saddle wyes shall have skirts with a minimum of 80 square inches (516 square cm) surface area which can be bonded to pipe. Fabricated saddle tees and saddle wyes shall have skirts with a minimum of 160 square inches (1032 square cm) surface area which can be bonded to pipe. The worm drive saddle straps used to fasten the saddles are manufactured with corrosion resistant 300 series AISI stainless steel. GPK does not recommend gasket skirts where air tests are required. Epoxy Reinforced Welds. 811 2 SECTION 4: WATER PIPE BENEFITS JM Eagle Blue Brute C900 pipe is the safe, long-lasting and stable solu- tion for a modern infrastructure. Blue Brute: • Maintains performance against tuberculation, corrosion and external gal- vanic soil conditions without lining wrapping, coating or cathodic protection. • Keeps its smooth interior over long years of service with virtually no loss in carrying capacity, allowing for savings in pumping costs, as well as sav- ings on the size of the pipe required. • Can be field-cut with a power saw or ordinary handsaw and be beveled without the use of expensive or complicated machinery. DESCRIPTION JM Eagle Blue Brute C900 is available in 4- through 12-inch diameters, in blue, white, purple and green. It comes in standard laying lengths of 20 feet. One length of 8-inch DR 18 pipe weighs approximately 184 pounds. The pipe conforms to AWWA C900 pressure class 165 psi (DR 25), 235 psi (DR 18) and 305 psi (DR 14). It carries approval of ANSI/NSF Standard 61, UL 1285 and FM 1612 (DR 18 and DR 14 only). APPLICATIONS JM Eagle’s Blue Brute C900 pipe is suitable for use in distribution pipelines of potable water, as well as gravity sewer, force main and water reclamation projects. Building essentials for a better tomorrow BLUE BRUTE™ MEETS AWWA C900 AND ASTM D1784 CELL CLASS 12454; GASKETS MEET ASTM F477; JOINTS MEET ASTM D3139. PLEASE CONTACT YOUR JM EAGLE REPRESENTATIVE OR VISIT WWW.JMEAGLE.COM FOR MORE INFORMATION. R e v i s e d 3 / 5 / 2 0 1 2 . T h i s i n f o r m a t i o n m a y h a v e b e e n u p d a t e d . P l e a s e d o w n l o a d t h e l a t e s t v e r s i o n a t w w w . j m e a g l e . c o m / o n e s h e e t s . Building essentials for a better tomorrow BLUE BRUTE™ SUBMITTAL AND DATA SHEET PIPE SIZE (IN) AVERAGE O.D. (IN) NOM. I.D. (IN) MIN. T. (IN) MIN. E (IN) APPROX. D9 (IN) APPROX. WEIGHT (LBS/FT) PRESSURE CLASS 165 psi (DR 25) 4 4.80 4.39 0.192 5.25 5.57 1.9 6 6.90 6.31 0.276 6.40 8.00 3.9 8 9.05 8.28 0.362 7.05 10.50 6.7 10 11.10 10.16 0.444 8.20 12.88 10.1 1 12 2 13.20 12.08 0.528 8.80 15.31 14.4 PRESSURE CLASS 235 psi (DR 18)* 4 4.80 4.23 0.267 5.25 5.87 2.6 6 6.90 6.09 0.383 6.40 8.43 5.3 8 9.05 7.98 0.503 7.05 11.06 9.2 10 11.10 9.79 0.617 8.20 13.57 13.9 12 13.20 11.65 0.733 8.80 16.13 19.7 PRESSURE CLASS 305 psi (DR 14)* 4 4.80 4.07 0.343 5.25 6.17 3.2 6 6.90 5.86 0.493 6.40 8.87 6.7 8 9.05 7.68 0.646 7.05 11.63 11.6 10 11.10 9.42 0.793 8.20 14.27 17.6 12 13.20 11.20 0.943 8.80 16.97 25.1 Consult JM Eagle™ for CSA and other listing availability prior to shipment. Note: *FM Approvals Pressure Class 150 psi for DR 18 and 200 psi for DR 14. * Contact your JM eagleTM sales representative for location availability. I.D. : Inside Dameter O.D. : Outside Diameter T. : Wall Thickness D9 : Bell Outside Diameter E : Distance between Assembly Mark to the end of spigot. Product Standard: Pipe Compound: Gasket: Integral Bell Joint: ANSI/AWWA C900 ASTM D1784 Cells Class 12454 ASTM F477 ASTM D3139 Certifications: Installation: ANSI/NSF Standard 61 UL Standard 1285 Pipe Length: 20 feet laying length AWWA C605 JM Eagle™ Installation Guide R e v i s e d 3 / 5 / 2 0 1 2 . T h i s i n f o r m a t i o n m a y h a v e b e e n u p d a t e d . P l e a s e d o w n l o a d t h e l a t e s t v e r s i o n a t w w w . j m e a g l e . c o m / o n e s h e e t s . BENEFITS Due to its long laying lengths of 20 feet, IPS Pressure PVC water pipe re-duces the cost of multiple joints and allows for more ground to be covered during installation. JM Eagle IPS Pressure pipe: • Maintains performance against tuberculation, corrosion and external galvanic soil conditions without lining wrapping, coating or cathodic protection. • Can be field-cut with a power saw or handsaw, eliminating the need to invest in costly cutting equipment. • Maintains smooth interior over long years of service with virtually no loss in carrying capacity, allowing for savings in pumping costs, as well as savings on the size of the pipe required. DESCRIPTION JM Eagle’s IPS Pressure PVC pipe is available in 1 ½- to 12-inch diameters, in SDR 64 (63 psi), SDR 41 (100 psi), SDR 32.5 (125 psi), SDR 26 (160 psi), SDR 21 (200) psi and SDR 17 (250 psi). The standard laying length of IPS Pressure PVC water pipe is 20 feet. JM Eagle manufactures this pipe in blue for irrigation applications, purple for reclaimed water systems, and green for sewer force mains. JM Eagle pipe comes with Ring-Tite joints. JM Eagle gaskets meet or exceed ASTM D3139 for joint tightness, including a 22-inch Hg vacuum for one hour, under deflection with no leakage. APPLICATIONS JM Eagle’s IPS Pressure is pipe suitable for use in rural water, and agricul-tural and turf irrigation pipelines, as well as gravity sewer, force main and water reclamation projects. Building essentials for a better tomorrow IPS PRESSURE / RING-TITE MEETS ASTM D2241, ASTM D1784 CELL CLASS 12454; GASKETS MEET ASTM F477; JOINTS MEET ASTM D3139. PLEASE CONTACT YOUR JM EAGLE REPRESENTATIVE OR VISIT WWW.JMEAGLE.COM FOR MORE INFORMATION. R e v i s e d 1 1 / 1 / 2 0 1 0 . T h i s i n f o r m a t i o n m a y h a v e b e e n u p d a t e d . P l e a s e d o w n l o a d t h e l a t e s t v e r s i o n a t w w w . j m e a g l e . c o m / o n e s h e e t s . JM EAGLE’S RING-TITE JOINT OFFERS ADDITIONAL BENEFITS. • Seated in a deep groove, the flexible elastomeric gasket provides a tight seal that protects the line from shock, vibration and earth movement, and compensates for expansion and contraction of the pipe lengths. • Quick and easy to assemble with a simple push, there’s no field mixing or application of cement. • The joint remains tight under normal operating conditions. Building essentials for a better tomorrow IPS PRESSURE / RING-TITE SUBMITTAL AND DATA SHEET PIPE SIZE (IN) AVERAGE O.D. (IN) NOM. I.D. (IN) MIN. T. (IN) MIN. E (IN) APPROX. D9 (IN) APPROX. WEIGHT (LBS/FT) Rated 63 psi (SDR 64) 6 6.625 6.40 0.104 5.50 7.20 1.60 8 8.625 8.33 0.135 6.25 9.30 2.40 10 10.750 10.39 0.168 6.75 11.50 3.80 12 12.750 12.32 0.199 8.00 13.80 5.30 Rated 100 psi (SDR 41)* 3 3.500 3.320 0.085 4.20 3.84 — 4 4.500 4.267 0.110 4.50 4.94 1.03 5 5.563 5.27 0.136 4.65 6.10 1.60 6 6.625 6.282 0.162 5.20 7.27 2.23 8 8.625 8.180 0.210 5.90 9.47 3.75 10 10.750 10.195 0.262 6.70 11.80 5.86 12 12.750 12.091 0.311 8.10 13.99 8.28 Rated 125 psi (SDR 32.5)* 1.5 1.900 1.773 0.060 3.45 2.14 — 2 2.375 2.220 0.073 3.70 2.67 — 2.5 2.875 2.688 0.088 3.95 3.23 — 3 3.500 3.271 0.108 4.20 3.93 0.77 4 4.500 4.207 0.138 4.50 5.05 1.28 5 5.563 5.200 0.171 4.65 6.25 2.00 6 6.625 6.193 0.204 5.20 7.44 2.79 8 8.625 8.063 0.265 5.90 9.69 4.70 10 10.750 10.048 0.331 6.70 12.07 7.35 12 12.750 11.919 0.392 8.10 14.32 10.36 Rated 160 psi (SDR 26)* (G) (P) 1.5 1.900 1.745 0.073 3.45 2.19 0.28 2 2.375 2.182 0.091 3.70 2.74 0.44 2.5 2.875 2.642 0.110 3.50 3.32 0.64 3 3.500 3.214 0.135 4.10 4.04 0.95 4 4.500 4.133 0.173 4.50 5.19 1.58 5 5.563 5.109 0.214 4.65 6.42 2.40 6 6.625 6.084 0.255 5.20 7.65 3.44 8 8.625 7.921 0.332 5.90 9.95 5.85 10 10.750 9.874 0.413 6.70 12.40 9.12 12 12.750 11.711 0.490 8.10 14.71 12.89 PIPE SIZE (IN) AVERAGE O.D. (IN) NOM. I.D. (IN) MIN. T. (IN) MIN. E (IN) APPROX. D9 (IN) APPROX. WEIGHT (LBS/FT) Rated 200 psi (SDR 21)* (G) (P) 1.5 1.900 1.709 0.090 3.45 2.26 0.44 2 2.375 2.135 0.113 3.70 2.83 0.54 2.5 2.875 2.585 0.137 3.95 3.42 0.79 3 3.500 3.146 0.167 4.20 4.17 1.17 4 4.500 4.046 0.214 4.50 5.36 1.93 6 6.625 5.955 0.316 5.20 7.89 4.23 8 8.625 7.754 0.410 5.90 10.27 7.18 10 10.750 9.667 0.511 6.70 12.79 11.20 12 12.750 11.465 0.606 8.10 15.17 15.82 Rated 250 psi (SDR 17)* (G) (P) 1.5 1.900 1.641 0.112 3.45 2.39 0.58 2 2.375 2.078 0.140 3.70 2.94 0.66 2.5 2.875 2.517 0.169 3.95 3.55 — 3 3.500 3.063 0.206 4.20 4.32 1.42 4 4.500 3.938 0.265 4.50 5.56 2.36 6 6.625 5.803 0.390 5.20 8.19 5.11 8 8.625 7.553 0.508 5.90 10.66 8.69 10 10.750 9.410 0.632 6.70 13.28 13.55 12 12.750 11.160 0.750 8.10 15.75 19.20 9 R e v i s e d 1 1 / 1 / 2 0 1 0 . T h i s i n f o r m a t i o n m a y h a v e b e e n u p d a t e d . P l e a s e d o w n l o a d t h e l a t e s t v e r s i o n a t w w w . j m e a g l e . c o m / o n e s h e e t s . SECTION 5: GATE VALVES & VALVE BOXES MODEL 2639 & 2640 F-6100 516509_B 11/16/10 2:40 AM Page 8 MODEL 2639 & 2640 F-6106 516509_B 11/16/10 2:40 AM Page 9 SUBMITTAL (Current Revisions for All Standards Apply) SIZES: ............................ Adjustable Slip and Screw type with standard assembled lengths ranging from 19” to 72” (Lengths noted do not include the addition of risers, extensions, and/or bases). See the Catalog or List Price guide for access., lids, rings, bases, risers, meter covers, etc. STANDARDS: ................. Produced with Class 35 cast iron in accordance with and meeting all applicable terms and provisions of ASTM A-48. All Tyler Union valve boxes when properly installed are suitable for use in conjunction with projects utilizing American Association of State Highway and Transportation Officials (AASHTO) standards and provisions. INSTALLATION: ............. Per AWWA M44, Manual of Water Supply Practices COATING: ...................... The asphaltic bituminous coating is applied to a minimum thickness of 1.5 mil and the coating once dry is neither brittle when exposed to cold or sticky when exposed to the sun. Tyler:11910 CR 492-Tyler,TX 75706-(800) 527-8478 Anniston:1501 W. 17th Street-Anniston, AL 36201-(800) 226-7601 Corona:1001 El Camino Ave.-Corona, CA 92879-(866) 527-8471 Portland: 6204 N. Marine Dr.-Portland, OR 97203-(866) 527-8471 www.tylerunion.com 69 29U-Domestic Heavy Duty Cast Iron Curb, Service, & Valve Boxes + Components Revised 04/2013 6500 SCREW TYPE CURB / SERVICE BOX Extension Componets In Inches 18T & 27B 30-42 18T & 33B 36-48 24T & 33B 36-54 24T & 39B 42-60 30T & 39B 41-64 *Enlarged Base Available 6850 SCREW TYPE VALVE BOX Cast Iron - 2 piece Extension Components Height 10T + 15B 19-22 10T + 24B 27-32 16T + 24B 27-37 16T + 30B 33-43 16T + 36B 39-50 26T + 30B 36-52 26T + 36B 39-60 26T + 24B + #60 Ext 53-71 26T + 36B + #60 Ext 64-82 6855 SLIP TYPE VALVE BOX Cast Iron - 2 piece Extension Components Height 10T + 15B 19-22 10T + 24B 27-32 16T + 24B 27-37 16T + 30B 33-43 16T + 36B 39-50 26T + 30B 36-52 26T + 36B 39-60 26T + 24B + #60 Ext 53-71 26T + 36B + #60 Ext 64-82 6860 SCREW TYPE VALVE BOX Cast Iron - 3 piece Extension Components) Height 10T + 12B 27-37 10T + 18B 33-42 16T + 24B 39-49 16T + 30B 45-54 16T + 36B 51-60 26T + 30B 45-66 26T + 36B 51-72 NOTE: Base Required, Order Separately 7126 SLIP TYPE VALVE BOX Extension Components Height 26T + 24B 28-48 26T + 30B 34-54 26T + 36B 40-60 26T + 24B + #60 Ext 52-72 26T + 36B + #60 Ext 60-80 NOTE: Use the 6855 Bottoms with these Tops For 4” to 12” Valves 5¼” Shaft, Screw Type For 3” to 20” Valves 5¼” Shaft, Screw Type For 4” to 12” Valves 5¼” Shaft, Slip Type For ½” to 2” Curbstops For 4” to 12” Valves 5¼” Shaft, Slip Type T = Top B = Bottom EXT = Extension SECTION 6: FIRE HYDRANTS ,6–, or 8" or Tyton (6") 516509_A 11/16/10 2:17 AM Page 1 516509_A 11/16/10 2:17 AM Page 2 516509_A 11/16/10 2:17 AM Page 3 516509_A 11/16/10 2:17 AM Page 4 A 516509_A 11/16/10 2:17 AM Page 5 516509_A 11/16/10 2:17 AM Page 7 516509_A 11/16/10 2:17 AM Page 8 516509_A 11/16/10 2:17 AM Page 9 SECTION 7: DUCTILE IRON FITTINGS, RESTRAINTS, & ACCYS DOMESTIC PRODUCT SUBMITTAL Current Revisions Apply for all Listed Standards SIZES:…………..…....… 2” through 48” STANDARDS:……..…... ANSI/AWWA C110/A21.10, NFPA 13/24, 3” - 12” UL listed and approved (File - Tyler Union) Cast of ASTM A536 qualified ductile iron. Date code is cast on and required for traceability. PRESSURE RATING:... *Flanged fittings rated at 250 psi. Mechanical joints 2” – 24” rated at 350 psi and 30” – 48” at 250 psi. *Note: With the use of rubber annular ring flange gasket, 2” – 24” fittings can be rated at 350 psi. DEFLECTION:……..….. Max joint deflection 2”– 12”, 5° and 14”– 48”, 3°. Reduces by 50% at nominal pipe & fitting diameters NSF-61 & NSF-372:...... Meets all requirements including Annex G, Tyler Union’s Underwriters Laboratory listing MH16439. ASPHALTIC COATING: Per ANSI/AWWA C104/A21.4 and ANSI/AWWA C110/A21.10. CEMENT LINING:………. Per ANSI/AWWA C104/A21.4, with double cement lining available upon request. EPOXY COATING:……... Fusion bonded epoxy per ANSI/AWWA C116/A21.16. Additional coatings available upon request. BARE FITTINGS:..…… Available upon request. FASTENERS:………….. High strength low alloy weathering steel per ANSI/AWWA C111/A21.11 and ASTM A242 INSTALLATION:…….… Install per AWWA C600/C651 using pipe conforming to ANSI/AWWA C151/A21.51 or AWWA C900/905. *Tyler Union Waterworks – Call Center Contact Information* Tyler: 11910 CR 492 ● Tyler, Texas 75706 ● (800) 527-8478 Anniston: 1501 W 17th St. ● Anniston, AL 36201 ● (800) 226-7601 Corona: 1001 El Camino Ave. ● Corona, CA 92879 ● (866) 527-8471 59 Mechanical Joint Retainer (UFR1500-CA-x-U style) FEATURES • Full circle contact and support of the pipe wall. • “Auto-Tork” actuating screws with heads specially designed to twist off at the correct installation torque, leaving a hex head in case future system maintenance or removal is required • Set of high strength, low alloy t-Bolts and nuts (AWWA C111) • Mechanical joint gasket (AWWA C111) • Series 1500 eliminates the need to pour expensive and time consuming concrete thrust blocks • Series 1500 UL/FM approved, 4"-12" nominal size C900 PVC, for use on listed and approved PVC pipe • Restraining segments are mechanically retained in pockets • Gland, screws and segments are black epoxy coated using the e-coat process • Gland colored red for identification purposes • Ductile iron castings are manufactured, assembled, inspected and packaged in the U.S.A. 4" - 12" SERIES UFR1500 CIRCLE LOCK MECHANICAL JOINT RESTRAINT FOR C900 OR C909 PVC PACKAGED WITH ACCESSORIES The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications, are subject to change without notice. Please verify that your product information is current. *Maximum O.D. of gland on pipe before Auto-Tork heads are removed (as shipped). **Maximum O.D. of gland on pipe after Auto-Tork heads are removed. SUBMITTAL INFORMATION The Ford Meter Box Company, Inc. P.O. Box 443, Wabash, Indiana U.S.A. 46992-0443 Phone: 260-563-3171 / Fax: 800-826-3487 Overseas Fax: 260-563-0167 www.fordmeterbox.com Submitted By: 12/05/14 Ductile iron actuating screw, with the Auto-Tork break-away head design, insures proper torque during installation. Ring segments are ductile iron per ASTM A536 and heat treated to a hardness of 370 BHN minimum Safety stop insures ring segments can never be over-tightened. Front Back Auto-Tork Bolt Restraint Segment Bolt Hole Cross Section Mechanical joint gasket High strength, low alloy t-bolts & nuts (AWWA C111) Gland body is of high strength ductile iron per ASTM A536, grade 65-45-12. Compatible with all mechanical joints conforming to ANSI / AWWA C111 / A21.11. NOM PIPE SIZE PIPE O.D. CATALOG NUMBER NO. OF SEGMENTS APPROX. WEIGHT (LBS) P1* P2** BC D PRESSURE RATING ✓SUBMITTED ITEM(S) C900 C909 C900 C909 DR-14 DR-18 DR-25 PC-235 4" 4.80 UFR1500-CA-4-U 4 14.20 13.00" 9.40" 7.50" 4.90" 305 235 165 6" 6.90 UFR1500-CA-6-U 6 20.10 15.13" 11.60" 9.50" 7.00" 305 235 165 235 8" 9.05 UFR1500-CA-8-U 6 25.00 17.25" 13.75" 11.75" 9.15" 305 235 165 235 10" 11.10 UFR1500-CA-10-U 8 33.00 19.38" 16.00" 14.00" 11.20" 305 235 165 235 12" 13.20 UFR1500-CA-12-U 8 38.00 21.50" 18.05" 16.25" 13.30" 305 235 165 235 1406 Hutton Drive Carrollton, TX 75006 120 Iron Horse, Suite A Hutto, TX 78634 Phone: (972) 446-1655 Fax: (972) 446-1684 Email: sales@egwutilities.com 304 Stainless Steel Hex Cap Screws & Hex Nuts Submittal Stainless steel bolts are manufactured to the dimensional specification ASME B18.2.1 and conform to ASTM F593 Type 304 . Stainless steel nuts are manufactured to the dimensional specification ASME B18.2.2 and conform to ASTM F594 Type 304. Nuts shall be regular or heavy hex. Bolting will be import material unless the order specifically calls out for domestic. Both import and domestic bolting conform to the above specifications. Red / Black SBR Material Specification Flange Gasket dimensional requirements are I/A/W ANSI/ASME B16.21 Styrene Butadiene Rubber (SBR) Red Rubber ASTM - D1330 Grade 1 SBR is recommended for low temperature applications for the plumbing and water services. Gaskets conform to ANSI/AWWA C111/A21.11. • Easily conforms to uneven flange surfaces • Operating Temperature: -20°F – 180°F • Elongation: 150% • Tensile Strength: 600 psi • Durometer: 75 (+/- 5) Shore A • Thickness will be 1/8” thick (1/16” thick is available upon request) • Suitable for water line pressure testing up to 300 psi WHITERHINO 1406 Hutton Drive, Carrollton, TX 75006 | Phone: 972.446.1655 | Fax: 972.446.1684 | sales@egwusa.com SECTION 8: FIRE LINE RISERS ES-A-InBuildingRiser Series IBR In-Building Risers are used to connect the main fire supply to the building overhead fire system. The fitting passes under the foundation without joints and ex- tends up through the floor. Provided with installation tabs, the unit has a CIPS (Cast Iron Pipe Size) coupler for easy connection to the underground supply (AWWA C900 PVC and Ductile Iron Pipe) and industry standard grooved-end connection (AWWA C606) on the building side for easy connection to the overhead fire sprinkler system. The IBR features Lead Free* construction to comply with Lead Free* installation requirements. Ames In-Building Risers are precision engineered and manufactured to provide exceptional reliability and reduce installation time & labor costs associated with field assembly. In accordance with NFPA 24, the UL/FM approved In-Building Risers replace numerous fittings, elbows & spools and reduces the possibility of leaks or failure in comparison to traditional installation methods and materials. Factory tested integrity ensures the highest quality installation. The use of stainless steel significantly increases the reliability and life of the riser. Features • Cost savings • Corrosion resistant stainless steel construction, type 304 • Ease of installation and light weight allows one person to position and handle the riser • Minimal site preparation; joint restraint one- piece construction reduces time and labor; no missing parts, no leaks; easily identifiable for approvals • Includes Test Cap and Coupler • UL/FM approved • Sizes: available in 4" – 10" (100-250mm) with various lengths to meet local require- ments • Designed to meet NFPA 24 • AWWA C900 Inlet/DIP • AWWA C606 Outlet Building perimeter wall Flow Building Floor F l o w TEST CAP NOW INCLUD E D ! * The wetted surface of this product contacted by consumable water contains less than 0.25% of lead by weight. Series IBR In-Building Risers Customizable Sizes: 4" – 10" (100 – 250mm) LEAD FREE* 6'x6' standard length (custom lengths from 3' – 20' available) For Fire Protection Applications Job Name –––––––––––––––––––––––––––––––––––––––––––– Contractor –––––––––––––––––––––––––––––––––––––––––––– Job Location –––––––––––––––––––––––––––––––––––––––––– Approval –––––––––––––––––––––––––––––––––––––––––––––– Engineer ––––––––––––––––––––––––––––––––––––––––––––– Contractor’s P.O. No. ––––––––––––––––––––––––––––––––––– Approval ––––––––––––––––––––––––––––––––––––––––––––– Representative ––––––––––––––––––––––––––––––––––––––––– Ames Fire & Waterworks product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measure- ments, please contact Ames Fire & Waterworks Technical Service. Ames Fire & Waterworks reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifications on Ames Fire & Waterworks products previously or subsequently sold. Size (dn) Weight A (OD) B C in. mm in. mm ft. cm ft. cm lbs. kg 4 100 41⁄2 114 6 183 6 183 71 32 6 150 65⁄8 168 6 183 6 183 98 44 8 200 85⁄8 219 6 183 6 183 129 59 10 250 103⁄4 273 6 183 6 183 202 92 Standards NFPA — Designed to allow the contractor to conform to NFPA 24 Where a riser is close to building foundations, underground fittings of proper design and type shall be used to avoid pipe joints being located under the foundations. End Connections Horizontal End: Mates with Ductile Iron Pipe and AWWA C900 Pipe (PVC Pipe with Ductile Iron Pipe Equivalent OD’s) Utilizes Gasket conforming to UL 157 with “Lock in” gasket configuration Vertical End: Meets AWWA C-606 dimensions for roll grooved pipe Meets AWWA C-207 class D for flanges Ratings Meets AWWA C-900 pressure class 200, DR 14 Pipe Testing Welds are 100% leak tested at the factory Size (dn) Mating PiPe Od in. mm in. mm 4 100 4.8 122 6 150 6.9 175 8 200 9.1 230 10 250 11.1 282 Size deSign PrOOF PreSSure in. mm psi bar 4 100 1000 70 6 150 1000 70 8 200 800 56 10 250 800 56 a grooved end (Flange Optional) CiPS Coupling tie-rod Bracket C B Approvals Fittings FM class 1920 UL HKQA (4"-10") Dimensions – Weights Specifications In-Building Riser shall be installed as indicated on the plans. Riser shall be composed of a single extended 90 degree fitting of fabricated 304 stainless steel tubing, maximum working pressure 200psi (14 bar). The fitting shall have a grooved-end connection on the outlet (building) side and a CIPS coupler on the inlet (underground) side. The grooved end shall include a coupler and cap to facilitate testing of the underground pip- ing. The In-Building Riser shall be an Ames Fire & Waterworks Series IBR. NOTICE Inquire with governing authorities for local installation requirements ES-A-InBuildingRiser 1540 © 2015 Ames Fire & Waterworks USA: Backflow Tel: (978) 689-6066 • Fax: (978) 975-8350 • AmesFireWater.com USA: Control Valves Tel: (713) 943-0688 • Fax: (713) 944-9445 • AmesFireWater.com Canada: Tel: (905) 332-4090 • Fax: (905) 332-7068 • AmesFireWater.ca Latin America: Tel: (52) 81-1001-8600 • Fax: (52) 81-8000-7091 • AmesFireWater.com A Watts Water Technologies Company ** Each B (vertical) and C (horizontal) leg is customizable from 3' to 20' with UL/FM approvals. Consult with your factory representative for details.The information contained herein is not intended to replace the full product installation and safety information available or the experience of a trained product installer. You are required to thoroughly read all installation instructions and product safety information before beginning the installation of this product. NOTICE SECTION 9: WATER SERVICE MATERIALS * Please Note: 4" Saddles with 2" taps have a limited range. Specifically, 4.80 - 5.10 or 5.10 - 5.40. All other tap sizes have the standard 4.80 - 5.40 range. **Only the 6" (6.90-7.50 range) saddle and 14" saddles and larger are available with a 1-1/4" tap. * To Order: Select the catalog number for the desired pipe range and complete the catalog number by adding the outlet thread tap code. Example: A double strap saddle for 6.90 D.I. pipe with a 3/4" CC thread would be 202B-750-CC3. FEATURES • All brass conforms to AWWA Standard C800 (ASTM B-62 and/or ASTM B-584, UNS NO C83600 - 85-5-5-5) • Straps are 5/8" high quality silicon bronze flattened to provide a wider bearing surface against pipe • Gasket is EPDM rubber ASTM D2000 • Approved to ANSI/NSF Standard 61 (2007a) • 200 PSI rated working water pressure through 14" nominal pipe size NOM. PIPE SIZE O.D. RANGE APPROX. WT. LBS. CATALOG NUMBER ✓ SUBMITTED ITEM(S) *4" 4.80 - 5.40 6.6 202B-540-Tap 4.80 - 5.10 7.3 202B-510-Tap 5.10 - 5.40 7.3 202B-540-Tap **6"6.90 - 7.50 7.7 202B-750-Tap 8"9.05 - 9.62 8.8 202B-962-Tap 10"11.10 - 12.12 10.7 202B-1212-Tap 12"13.20 - 14.38 11.8 202B-1438-Tap **14"15.30 - 16.25 18.0 202B-1625-Tap **16" 16.30 - 17.25 19.1 202B-1725-Tap 17.40 - 18.40 23.0 202B-1840-Tap 18.50 - 19.25 24.0 202B-1925-Tap **18"19.50 - 20.50 25.0 202B-2050-Tap **20"21.20 - 22.20 25.5 202B-2220-Tap 22.50 - 23.50 25.7 202B-2350-Tap **24"23.80 - 24.80 26.0 202B-2480-Tap 25.60 - 26.50 26.5 202B-2650-Tap **30"31.74 - 32.74 27.0 202B-3274-Tap EPDM Gasket Silicon bronze straps Brass nuts The Ford Meter Box Company, Inc. P.O. Box 443, Wabash, Indiana U.S.A. 46992-0443 Phone: 260-563-3171 / Fax: 800-826-3487 Overseas Fax: 260-563-0167 http://www.fordmeterbox.com Submitted By: The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications, are subject to change without notice. Please verify that your product information is current. 09/18/13 Brass Saddles - (202B-xxx-xxx style) SUBMITTAL INFORMATION 202B DOUBLE STRAP BRASS SADDLES OUTLET TAP CODE CC (AWWA) THREAD IP THREAD ✓ SUBMITTED ITEM(S)THREAD CODE NUMBER THREAD CODE NUMBER 3/4" CC CC3 3/4" IP IP3 1" CC CC4 1" IP IP4 1-1/4" CC ∆ CC5 1-1/4" IP ∆ IP5 1-1/2" CC CC6 1-1/2" IP IP6 2" CC CC7 2" IP IP7 ∆ Contact factory for availability AWWA/CC TAPER THREAD INLET BY QUICK JOINT FOR COPPER OR PLASTIC TUBING (CTS) OUTLET VALVE SIZE INLET SIZE OUTLET SIZE VALVE LENGTH BODY OUTLET THREADS APPROX. WT. LBS PART NUMBER ✓ SUBMITTED ITEM(S) 3/4" 3/4" 3/4" 4-19/64" 3/4" Flare Copper 1.6 FB1000-3-Q-NL 1" 1" 1" 4-31/64" 1" Flare Copper 2.6 FB1000-4-Q-NL 1" 1" 1-1/4" 4-5/16" 1-1/4" Special Thread 3.4 *FB1000-45-Q-NL 1-1/4" 1-1/4" 1-1/4" 5-21/32" 1-1/4" Special Thread 4.3 *FB1000-5-Q-NL 1-1/2" 1-1/2" 1-1/2" 5-45/64" 1-1/2" Special Thread 5.4 FB1000-6-Q-NL 2" 2" 2" 7-1/16" 2" Special Thread 8.2 FB1000-7-Q-NL The Ford Meter Box Company, Inc. P.O. Box 443, Wabash, Indiana U.S.A. 46992-0443 Phone: 260-563-3171 / Fax: 800-826-3487 Overseas Fax: 260-563-0167 www.fordmeterbox.com Submitted By: The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications, are subject to change without notice. Please verify that your product information is current. 03/30/16 Ballcorp Corporation Stops - (FB1000-xx-Q-NL style) SUBMITTAL INFORMATION Note: Ford recommends using insert stiffeners with plastic pipe or tubing. * 1-1/4" Quick Joint has EPDM spring tip gasket. Fluorocarbon-coated brass ball External Nut Stop Molded Buna-N Spring Tip Gasket provides Hydraulic Seal Stainless Steel Gripper Quick Joint Nut Inlet Solid one piece tee-head and stem Dual EPDM O-rings in the stem AWWA/CC Threads Outlet External Nut Stop Body Outlet Threads Molded EPDM rubber seat with reinforcing ring supports the ball FEATURES • All brass that comes in contact with potable water conforms to AWWA Standard C800 (ASTM B584, UNS C89833) • The product has the letters “NL” cast into the main body for lead-free identification • Certified to NSF/ANSI Standard 61 and NSF/ANSI Standard 372 where applicable • Brass components that do not come in contact with potable water conform to AWWA Standard C800 (ASTM B62 and ASTM B584, UNS C83600, 85-5-5-5) • Ends are integral or secured with adhesive to prevent unintentional disassembly • 300 PSI working pressure Image shown above is an FB1000-4-Q-NL. EPDM O-ring Length FEATURES • All brass that comes in contact with potable water conforms to AWWA Standard C800 (UNS NO C89833) • The product has the letters "NL" cast into the main body for proper identification • UL Classified to ANSI/NSF Standard 61 and Standard 61 Annex G (NSF/ANSI 372) • Brass components that do not come in contact with potable water conform to AWWA Standard C800 (ASTM B-62 and ASTM B-584, UNS NO C83600 - 85-5-5-5) • Padlock Wing for locking the valve in a closed position. "WW" indicates Double Padlock Wings for locking valve in open or closed position • Meets 100 PSI pressure requirement of AWWA Standard C800 GRIP JOINT FOR COPPER OR PLASTIC TUBING (CTS) INLET BY METER SWIVEL NUT OUTLET Length F O R D Two phosphor bronze spring washers under the tee head reseat the key after turning Height Bronze pin securely locks the tee head to the inverted key Padlock Wing for locking valve in closed position Buna-N O-ring in the inverted key Sturdy stops allow 150° motion The Ford Meter Box Company, Inc. P.O. Box 443, Wabash, Indiana U.S.A. 46992-0443 Phone: 260-563-3171 / Fax: 800-826-3487 Overseas Fax: 260-563-0167 http://www.fordmeterbox.com Submitted By: The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications, are subject to change without notice. Please verify that your product information is current. 05/10/13 EPDM Rubber Meter Gasket Meter Coupling Thread Bronze Snap Ring Nylon Washer Grip Joint Nut Beveled EPDM rubber gasket provides hydraulic seal Phosphorous Bronze Gripper Ring for axial restraint Angle Key Meter Valves - (KV43-xxxW-G-NL style) SUBMITTAL INFORMATION Meter Swivel Nut Inlet Outlet Drilled for Seal Wire VALVE SIZE SERVICE LINE SIZE INLET METER SIZE OUTLET LENGTH HEIGHT APPROX. WT. LBS PART NUMBER ✓ SUBMITTED ITEM(S) 3/4" 3/4" 5/8" 1-11/16" 1-5/8" 1.4 KV43-331W-G-NL 3/4" 3/4" 5/8”x3/4” & 3/4" 1-11/16" 1-5/8" 1.6 KV43-332W-G-NL 3/4" 1" 5/8" 1-11/16" 2" 1.4 KV43-341W-G-NL 3/4" 1" 5/8”x3/4” & 3/4" 1-11/16" 2" 1.7 KV43-342W-G-NL 1" 1" 1" 1-15/16" 1-9/16" 2.3 KV43-444W-G-NL 1" Dbl. Locking 1" 1" 1-15/16" 1-9/16" 2.2 KV43-444WW-G-NL 1" 1-1/4" 1" 1-15/16" 1-7/8" 2.7 KV43-454W-G-NL Note: Ford recommends using insert stiffeners with plastic pipe or tubing. FEATURES • All brass that comes in contact with potable water conforms to AWWA Standard C800 (ASTM B584, UNS C89833) • The product has the letters “NL” cast into the main body for lead-free identification • Certified to NSF/ANSI Standard 61 and NSF/ANSI Standard 372 where applicable • Brass components that do not come in contact with potable water conform to AWWA Standard C800 (ASTM B62 and ASTM B584, UNS C83600, 85-5-5-5) • Valve is non-directional and is watertight with flow in either direction • Ends are integral or secured with adhesive to prevent unintentional disassembly • Hole for attaching curb box rod or handle is provided in tee-head • 300 PSI working pressure Optional Padlock Wing for locking valve in closed position. Insert “W” into part number. QUICK JOINT FOR COPPER OR PLASTIC TUBING (CTS) INLET BY FEMALE IRON PIPE THREAD OUTLET Inlet Length Solid one piece tee-head and stem Sturdy stops allow 90° motion and are enclosed and protected.A snap ring locks the stem into the body of the valve Dual EPDM O-rings in the stem Molded EPDM rubber seat with reinforcing ring supports the ball Fluorocarbon-coated brass ball Outlet The Ford Meter Box Company, Inc. P.O. Box 443, Wabash, Indiana U.S.A. 46992-0443 Phone: 260-563-3171 / Fax: 800-826-3487 Overseas Fax: 260-563-0167 www.fordmeterbox.com Submitted By: The Ford Meter Box Company considers the information in this submittal form to be correct at the time of publication. Item and option availability, including specifications, are subject to change without notice. Please verify that your product information is current. 03/13/15 External Nut Stop Stainless Steel Gripper Ball Valve Curb Stop - (B41-xxx-Q-NL style) SUBMITTAL INFORMATION Optional Padlock Wing for locking valve in closed position Quick Joint Nut Female Iron Pipe OutletMolded Buna-N Spring Tip Gasket Provides Hydraulic Seal VALVE SIZE INLET SIZE OUTLET SIZE LENGTH APPROX. WT. LBS PART NUMBER ✓ SUBMITTED ITEM(S) 3/4" 3/4" 3/4" 3-37/64" 1.8 B41-333-Q-NL 3/4" 1" 3/4" 3-57/64" 2.2 B41-343-Q-NL 3/4" 1" 1" 4-1/64" 2.3 B41-344-Q-NL 1" 1" 1" 3-19/32" 2.5 B41-444-Q-NL 1-1/4" 1-1/4" 1-1/4" 5-3/16" 5.0 B41-555-Q-NL 1-1/2" 1-1/2" 1-1/2" 5-5/64" 5.9 B41-666-Q-NL 2" 2" 2" 5-29/32" 8.3 B41-777-Q-NL Note: Ford recommends insert stiffeners when using plastic pipe or tubing. Image shown above is a B41-444-Q-NL SECTION 10: POLYWRAP, POLYTAPE, TRACER WIRE & FILTER FABRIC P.O. Box 38409 · 10355 Sanden Drive · Dallas, TX 75238 · 214.503.2576 · Fax 469.547.4242 · www.agavewire.com Toll-Free (800) 690-3408 ISO 9001:2000 Certified Fax: (469) 547-4242 PRODUCT DATA SHEET PRODUCT OVERVIEW: APCS/APSS-1401 (Flexible CCS Tracer Wire) CONSTRUCTION: One 14 AWG Copper Clad Steel HMW-PE Insulated Conductor APPROVALS : UL – Tracer Wire. Direct burial rated. APPLICATION : Tracer Wire Suitable For Detecting Buried Facilities CONSTRUCTION PARAMETERS: CONDUCTOR : 14 AWG Copper Clad Steel STRANDING : Solid NUMBER OF CONDUCTORS : 1 INSULATION MATERIAL : HMW-PE (High Molecular Weight Polyethylene ) INSULATION THICKNESS : 0.030” Nominal COPPER O.D. : 0.064” Nominal FINISHED O.D. : 0.126” Nominal WEIGHT PER 1000ft : 14.85 lbs /1000’ ELECTRICAL & ENVIRONMENTAL PROPERTIES: TEMPERATURE RATING : -20°c to 80°c OPERATING VOLTAGE : 30v INSULATION COLOR : Various Colors Available BREAK LOAD: 175-177 LBS TENSILE STRENGTH: 54,251-55,000 PSI PRINT LEGEND: “AGAVE WIRE - 14AWG HMW-PE-(30) COPPER CLAD STEEL TRACER WIRE (UL) 30v E246360 ” On special orders, the customer will accept all mil lengths and +/- 10% of total order requested. The information presented here is, to the best of our knowledge, is true and accurate. However, since conditions of use are beyond our control, all recommendations or suggestions are presented without guarantee or responsibility on our part. We disclaim all liability in connection with the use of information contained herein or otherwise This specification is proprietary intellectual property of Agave Wire. Any information contained herein shall not be disclosed to any party without written consent of Agave Wire. Manufactured in the U.S.A. 0.064 ” 0.126 ” 1406 Hutton Drive Carrollton, TX 75006 120 Iron Horse, Suite A Hutto, TX 78634 Phone: (972) 446-1655 Fax: (972) 446-1684 Email: sales@egwutilities.com 513 Vinyl Pipe Wrapping Tape Production Description  Stabilized, plasticized PVC (poly vinyl chloride) film coated with a non- corrosive pressure sensitive adhesive Applications  Wrapping valves, elbows and fittings Features  Excellent moisture resistance  Non-corrosive  Outstanding Conformability  Adheres well to metal and plastic  Available in 2”, 4”, & 6” widths (stock 2”) Test Data Test Typical Value Typical Valve Test Method (Metric) Total Thickness 10 mil 0.25 mm ASTM D 1000 Adhesion to Steel 20 oz. /in. 2.4 N/10mm ASTM D 1000 Adhesion to Backing 20 oz. /in. 2.4 N/10mm ASTM D 1000 Tensile Strength 25 lb. /in. 43.8 N/10mm ASTM D 1000 Elongation at Break 200 % Dielectric Strength 1250 volts/mil Typical values are not intended to be used for specifications development. Technical data is believed to be true and accurate. We recommend the purchaser test the fitness for use for all applications. 1408 Hutton Drive Carrollton, TX 75006 120 Iron Horse, Suite A Hutto, TX 78634 Phone: (972) 446-1655 Fax: (972) 446-1684 Email:sales@egwutilities.com Submittal for Polyethylene Encasement for Ductile-Iron Pipe AWWA C105/A21.5-05 Raw material requirements, per ASTM D4976 Material: Linear low-density polyethylene film manufactured out of virgin polyethylene material. Physical properties of finished film Tensile Strength: 3.600 psi (24.8 MPa), minimum in machine and transverse direction (ASTM D882) Elongation: 800 percent, minimum in machine and transverse direction (ASTM D882) Dielectric Strength: 800 V/mil thickness, minimum (ASTM D149) Impact resistance: 600 g, minimum (ASTM D1709 Method B) Propagation tear resistance: 2,550 gf (grams force), minimum in machine and transverse direction (ASTM D1922) Thickness: minimum of 0.008 in. (8 mil) Color: Black, Clear, Purple and Brown (other colors are available upon request but are subject to factory minimum) The polywrap is manufactured in the United States by either AEP Industries or Mountain States Plastics in the United States. ______________________ TECHNICAL DATA SHEET Mirafi® 140N Mirafi® 140N is a nonwoven geotextile composed of polypropylene fibers, which are formed into a a stable network such that the fibers retain their relative position. 140N is inert to iological degradation and resists naturally encountered chemicals, alkalis, and acids. b Minimum Average Roll Value Mechanical Properties Test Method Unit MD CD Grab Tensile Strength ASTM D 4632-91 kN (lbs) 0.53 (120) 0.53 (120) Grab Tensile Elongation ASTM D 4632-91 % 50 50 Trapezoid Tear Strength ASTM D 4533-91 kN (lbs) 0.22 (50) 0.22 (50) Mullen Burst Strength ASTM D 3786-87 kPa (psi) 1550 (225) Puncture Strength ASTM D 4833-00 kN (lbs) 0.30 (65) Apparent Opening Size (AOS) ASTM D 4751-99A mm (U.S. Sieve) 0.212 (70) Permittivity ASTM D 4491-99A sec-1 1.8 Permeability ASTM D 4491-99A cm/sec 0.21 Flow Rate ASTM D 4491-99A l/min/m2 (gal/min/ft2) 5500 (135) UV Resistance (at 500 hours) ASTM D 4355-02 % strength retained 70 Physical Properties Test Method Unit Typical Value Weight ASTM D 5261-92 g/m2 (oz/yd2) 163 (4.8) Thickness ASTM D 5199-01 mm (mils) 1.4 (55) Roll Dimensions (width x length) -- m (ft) 3.8 x 110 (12.5 x 360) 4.5 x 110 (15 x 360) Roll Area -- m2 (yd2) 418 (500) 502 (600) Estimated Roll Weight -- kg (lb) 74 (164) 89 (197) Disclaimer: MIRAFI® Construction Products assumes no liability for the accuracy or completeness of this information or for the ultimate use by the purchaser. MIRAFI® disclaims any and all express, implied, or statutory standards, warranties or guarantees, including without limitation any implied warranty as to merchantability or fitness for a particular purpose or arising from a course of dealing or usage of trade as to any equipment, materials, or information furnished herewith. This document should not be construed as engineering advice. CPSS000385 ETQR2