Loading...
Security Fire Systems-LR170510 2424 STUTZ DR.  SUITE 400  DALLAS, TX 75235  TEL [214] 350 5600  FAX [214] 350 0019 REPORT OF FIELD DENSITY TESTS Security Fire Systems 196 S. Freeport Parkway Coppell, Texas REPORTED TO: Security Fire Systems, Inc. 196 Freeport Parkway Coppell, Texas 75019 ATTN: Mr. Mike Alexander REPORT NO. 14 REPORT DATE: 05-24-17 REG PROJECT NO. 21753 TECHNICIAN: J. Castaneda PAGE: 1 of 2 CONTRACTOR: Trest Construction Proctor No. ASTM Standard Description Optimum Moisture, % Maximum Density, PCF 1 D-698 Reddish brown clayey sand w/sandstone 12.2 109.9 2 D-698 Light brown sandy clay 13.5 110.5 3 D-698 Dark brown clayey sand 10.5 117.1 4 D-698 Reddish brown sandy clay 13.5 110.7 5 D-698 Red & light brown clayey sand 11.6 114.0 Test No. Date Location Depth Below Final S. G. (feet) Pocket Pen (tsf) Field Density (pcf) Field Moisture (%) Proctor ID Compaction Level (%) 110 05-10-17 Water Line A: STA 2+00 3.0 3.0 106.7 16.0 2 96.6 111 Water Line A: STA 2+01 2.0 3.0 107.5 17.6 2 97.3 112 Water Line A: STA 2+02 1.0 3.5 108.0 15.3 2 97.8 113 Water Line A: STA 2+03 0.0 3.25 107.7 16.3 2 97.5 114 0511-17 Storm Line A: STA 1+30 4.0 3.5 109.8 12.6 5 96.3 115 Storm Line A: STA 1+31 3.0 3.5 110.2 13.8 5 96.7 116 Storm Line A: STA 1+32 2.0 3.75 110.9 14.0 5 97.3 117 Storm Line A: STA 1+33 1.0 4.0 111.9 12.9 5 98.2 118 Storm Line A: STA 1+34 0.0 4.0 111.7 13.0 5 98.0 119 Storm Line A: STA 00+50 4.0 4.0 111.8 13.1 5 98.1 120 Storm Line A: STA 00+51 3.0 3.75 110.7 13.4 5 97.1 121 Storm Line A: STA 00+52 2.0 3.5 110.5 12.5 5 96.9 122 Storm Line A: STA 00+53 1.0 3.5 109.8 13.5 5 96.3 123 Storm Line A: STA 00+54 0.0 3.75 111.1 12.9 5 97.5 124 05-12-17 Water Line A: STA 5+00 3.0 3.5 106.7 16.4 2 96.6 125 Water Line A: STA 5+01 2.0 3.75 107.9 15.5 2 97.6 126 Water Line A: STA 5+02 1.0 3.75 107.7 15.9 2 97.5 127 Water Line A: STA 5+03 0.0 3.5 106.9 16.2 2 96.7 128 Water Line A: STA 6+50 3.0 3.25 105.9 15.8 2 95.8 129 Water Line A: STA 6+51 2.0 3.5 106.3 15.9 2 96.2 130 Water Line A: STA 6+52 1.0 3.5 106.7 16.5 2 96.6 131 Water Line A: STA 6+53 0.0 3.75 107.2 16.1 2 97.0 Comments: Where tested, materials were in compliance with project specifications. REPORT NO. 14 REPORT DATE: 05-24-17 REG PROJECT NO. 21753 PAGE: 2 of 2 E-Mail Distribution: (1) Security Fire Systems, Inc./ Mr. Mike Alexander (1) GPF Architects, LLC/Mr. Greg Frnka (1) Trest Construction/Mr. Gilbert Trevino (1) City of Coppell/Mr. Matthew Mabry (1) Trest Construction/Mr. Clement Wang (1) Trest Construction/Mr. Eric Larsen Submitted by: REED ENGINEERING GROUP, LTD. Registration Number F-3114 Bill Woolwine Sr. Manager, CMT BW/mg