Loading...
Freeport NIP(2.3)-LR 960702TECHNOLOGIES INC Maxim Tech. *Southwestern Labs 2200 Gravel Drive Fort Worth, Texas 76118-7123 Telephone: (817) 284-7755 FAX: 1817) 589-1420 CLIENT: PROJECT: REPORT OF CONCRETE COMPRESSIVE STRENGTH Larry Jackson Construction Co. 5112 Sun Valley Fort Worth, TX 76119 PROJECT NO.: 1103601210 REPORT NO.: 602702 City of Coppell DATE OF SERVICE: 6/04/96 440 Royal Lane AUTHORIZATION: REPORT DATE: 7/02/96 SERVICES: Sample concrete at location of placement, perform required field prepare and test concrete compressive strength specimens. tests, PROJECT DATA CONTRACTOR: CONCRETE SUPPLIER: TXI PLANT: #41 SPECIFICATION REQUIREMENTS STRENGTH: 3000psi ® 28 SLUMP: 3.5" AIR: N/G METHOD OF TEST: ASTM C- 31 ASTM Larry Jackson Construction Co. DAYS & C-39 C-143 CLASS OF CONCRETE: 8272 DATE OF PLACEMENT: 6/04/96 TIME SAMPLED: 02:00PM BY: Brian Kasten TEMPERATURE (0F)-AIR: 80 CONCRETE: 84 TRUCK NO: 464 TICKET NO: 602603 LOCATION OF PLACEMENT: Inlet walls, north end REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 1 2 CYLINDERS CYLINDER MEASURED MAXIMUM MARKED SLUMP DATE AGE DIAMETER AREA LOAD SET NO. (inches) TESTED (days) {in.) {sq.in.) {lbs. force) 1 1 1.50 6/11/96 7 6.00 28.27 118990 1 2 1.50 6/11/96 7 6.00 28.27 114130 1 3 1.50 7/02/96 28 6.00 28.27 149810 1 4 1.50 7/02/96 28 6.00 28.27 151570 COMPRESSIVE STRENGTH (psi) 4210 4040 5300 5360 REMARKS Technician: Brian Kasten Started: 01:00PM Stopped: 03:30PM Report Distribution: (2) Larry Jackson Construction Co. MAXIM TECH. · SOUTHWESTERN LABS (1) City of coppe[[ Tim Begole, CET. Office Manager 1001 BKF Our letters'and reports are for the excJusive use of the c ant to whom they are addressed and shall not be reproduced except in full without the approval of the testing laboratory The use of ourname must receive our written approval Our letters and reports apply only to the sample tested and/or inspected, and are not ndicative of the quantities of apparently identical or similar products.