Loading...
9th Grade Center-LR170530FIELD DENSITY TEST REPORT Report Number: Service Date: Report Date: Task: 94171164.0011 05/30/17 06/01/17 8901 Carpenter Fwy Ste 100 Dallas, TX 75247-4547 214-630-1010 Reg No: F-3272 Client Coppell ISD Attn: Louis Macias 1303 Wrangler Cir Coppell, TX 75019 Coppell ISD 9th Grade Center 1301 Wrangler Circle Coppell, TX 75019 Project Project Number: 94171164 Lab Test Data (%) Compaction Project Requirements (%) Content Water No. Mat. Material Information Density Max. Lab (%) Content Water Optimum Ref. No. Proctor Laboratory Classification and Description (pcf)Test Method 950/+31102.020.794171164.0001 Dark brown and gray clay with gravel ASTM D698 Field Test Data No.Test Location Elev.No. Test Lift /Mat.Depth Density Probe Wet Content Water (%) Content Water Density Dry (%) Percent Compaction (in)(pcf)(pcf)(pcf) Sanitary Sewer Line, Lateral 'B-7' 1 Sta. 0+82 2' BFG 1 6 122.7 22.6 22.6 100.1 98 2 Sta. 0+83 1' BFG 1 6 122.8 22.2 22.1 100.6 99 3 Sta. 0+84 Final 1 6 122.7 22.4 22.3 100.3 98 Comments: Datum:BFG = Below Final Grade Serial No:Std. Cnt. M:Std. Cnt. D:257472072500 Test and/or retest results on this report meet project requirements as noted above. Perform in-place moisture and density retests as requested or as required by the project specifications to determine degree of compaction and material moisture condition. Services: Reported To: Contractor: Contractor Northstar Builders Group, LLC Daniel Wood Project Manager Report Distribution: (1) Coppell ISD, Louis Macias (1) Corgan Associates Inc, Keith Cummins (1) Glenn Engineering, Robert Howman (1) Northstar Builders Group, Charles Posey (1) Northstar Builders Group, Jeff Miller (1) Northstar Builders Group, Justin Dunkin (1) Northstar Builders Group, Roberto Gonzales (1) Sizelove Construction, Nathan Hayward Reviewed By: Terracon Rep.: Paul Butler ASTM D6938Test Methods: The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. CR0007, 11-16-12, Rev.7 Page 1 of 1